文献速递白内障与屈光手术角膜与眼表疾病

PEARL-DGS公式在近视激光角膜屈光手术后眼内镜度数计算中的准确性

Accuracy of the PEARL-DGS Formula for Intraocular Lens Power Calculation in Post-Myopic Laser Refractive Corneal Surgery Eyes.
PubMed 文献 · Am J Ophthalmol · 2023-10-31

这项回顾性病例系列纳入139眼(139例)既往行近视激光角膜屈光手术并随后使用Tecnis ZCB00行白内障手术的患者,评估5种公式的屈光预测准确性。未行常数优化时PEARL-DGS的平均预测误差为+0.05±0.65D,其余公式呈近视漂移,中位绝对预测误差以PEARL-DGS最小(0.39D);常数优化后5种公式间中位绝对预测误差无统计学显著差异(P=.388)。作者建议临床医生无优化常数时可考虑将PEARL-DGS作为首选。

要点

  • 未行常数优化时PEARL-DGS平均预测误差为+0.05±0.65D,其他公式呈近视漂移。
  • 未优化时中位绝对预测误差PEARL-DGS为0.39D,小于其他4种公式(P<.05)。
  • 常数优化后5种公式中位绝对预测误差无统计学显著差异(P=.388)。

核心结论

  • 与其他眼内镜公式相比,未行常数优化时PEARL-DGS在近视激光角膜屈光手术后眼中取得更好的屈光结果。
  • 作者建议临床医生没有优化常数时可考虑将PEARL-DGS作为这类眼眼内镜度数计算的首选。

研究设计与样本

  • 回顾性病例系列,纳入2018年3月至2023年2月期间既往行近视激光角膜屈光手术并随后使用Tecnis ZCB00行白内障手术的139眼(139例),平均眼轴长度27.4±2.1mm。
  • 评估Barrett True K、Haigis-L、Hoffer-QST、PEARL-DGS和Shammas-PL共5种公式的屈光结果。
  • 预测误差定义为使用实际植入眼内镜度数时测得的与预测的术后屈光等效球镜度之差,计算平均预测误差、中位绝对预测误差和平均绝对预测误差。

主要发现

  • 未行常数优化时PEARL-DGS平均预测误差为+0.05±0.65D,其他公式呈近视漂移。
  • 未行常数优化时中位绝对预测误差按大小依次为PEARL-DGS 0.39D、Hoffer-QST 0.53D、Barrett True K 0.65D、Shammas-PL 0.85D、Haigis-L 1.11D(P<.05)。
  • 行常数优化后5种公式中位绝对预测误差无统计学显著差异(P=.388)。

关键数值与推荐

  • 预测误差定义为使用实际植入眼内镜度数时测得的与预测的术后屈光等效球镜度之差。
  • 未行常数优化时PEARL-DGS中位绝对预测误差为0.39D,Hoffer-QST为0.53D,Barrett True K为0.65D,Shammas-PL为0.85D,Haigis-L为1.11D(P<.05)。

临床怎么用

  • 作者建议临床医生没有优化常数时可考虑将PEARL-DGS作为这类眼眼内镜度数计算的首选(作者建议)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the accuracy of the PEARL-DGS formula for intraocular lens (IOL) power calculation in post-myopic laser refractive corneal surgery eyes. DESIGN: Retrospective case series. METHODS: A total of 139 eyes of 139 patients (mean axial length: 27.4 ± 2.1 mm) who had prior myopic laser refractive corneal surgery and subsequent cataract surgery using Tecnis ZCB00 from March 2018 to February 2023 were included. Refractive outcomes of 5 formulas (Barrett True K, Haigis-L, Hoffer-QST, PEARL-DGS, and Shammas-PL) were evaluated. Prediction error was defined as the difference between the measured and predicted postoperative refractive spherical equivalent using the IOL power actually implanted. Mean prediction error (MPE), median absolute prediction error (MedAE), and mean absolute prediction error were calculated. RESULTS: Without constant optimization, the PEARL-DGS resulted in a MPE of +0.05 ± 0.65 diopters (D), whereas the other formulas resulted in myopic shifts. The MedAEs of the formulas were 0.39, 0.53, 0.65, 0.85, and 1.11 D for the PEARL-DGS, Hoffer-QST, Barrett True K, Shammas-PL, and Haigis-L, respectively, in order of magnitude (P < .05). With constant optimization, there were no statistically significant differences in the MedAEs among the 5 formulas (P = .388). CONCLUSIONS: In comparison to other IOL formulas, the PEARL-DGS resulted in better refractive outcomes after cataract surgery in post-myopic laser refractive corneal surgery eyes without constant optimization. We suggest that PEARL-DGS be considered as the first choice for IOL power calculation in these eyes when the clinicians do not have their optimized constants.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Oh R, Hyon JY, Jeon HS, et al. Accuracy of the PEARL-DGS Formula for Intraocular Lens Power Calculation in Post-Myopic Laser Refractive Corneal Surgery Eyes. Am J Ophthalmol. 2023. PMID: 37914063. doi:10.1016/j.ajo.2023.10.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。