PubMed 文献 · Invest Ophthalmol Vis Sci · 2023-01-01

研究纳入29名健康年轻受试者、30例青光眼患者和20名年龄相仿对照者的单眼,用10-2网格和5种面积刺激测试,结合OCT结构数据建立空间总和计算模型。拟合比较H1(Ricco区变化)与H2(无Ricco区变化的敏感性丧失)两种假设,H1的RMSE为2.09(95%CI=1.92-2.26),低于H2的2.49(95%CI=2.24-2.72),P<0.001。结论认为青光眼黄斑敏感性丧失更好由Ricco区随视网膜神经节细胞丢失而变化的模型描述,结构测量的动态范围有限。

要点

  • H1(Ricco区变化)模型RMSE为2.09(95%CI=1.92-2.26),低于H2的2.49(95%CI=2.24-2.72),P<0.001。
  • 结构视网膜神经节细胞密度估计的平均动态范围仅为功能估计的11%。
  • 青光眼黄斑敏感性丧失更好由Ricco区随视网膜神经节细胞丢失而变化的模型描述。

核心结论

  • 青光眼黄斑敏感性丧失更好由Ricco区随视网膜神经节细胞丢失而变化的模型描述,结构测量的动态范围有限。

研究设计与样本

  • 研究纳入29名年龄小于40岁的视觉健康受试者、30例青光眼患者和20名年龄相仿对照者,每人测试单眼,采用10-2网格和5种不同面积大小的刺激,并从OCT扫描获得逐点视网膜神经节细胞密度的结构估计。
  • 利用年轻健康队列的结构和功能数据估计计算空间总和模型参数以生成模板,再用贝叶斯分层模型拟合模板以估计青光眼患者和年龄匹配对照者的潜在视网膜神经节细胞密度。
  • 比较两种替代假设:水平平移模板(H1:Ricco区变化)或垂直平移模板(H2:无Ricco区变化的敏感性丧失)拟合数据,比较模型拟合至视野敏感性的均方根误差(RMSE),并自举法计算95%置信区间。

主要发现

  • H1下RMSE为2.09(95%CI=1.92-2.26),H2下RMSE为2.49(95%CI=2.24-2.72),P<0.001。
  • 结构视网膜神经节细胞密度估计的平均动态范围仅为功能估计的11%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to test whether functional loss in the glaucomatous macula is characterized by an enlargement of Ricco's area (RA) through the application of a computational model linking retinal ganglion cell (RGC) damage to perimetric sensitivity. METHODS: One eye from each of 29 visually healthy subjects <40 years old, 30 patients with glaucoma, and 20 age-similar controls was tested with a 10-2 grid with stimuli of 5 different area sizes. Structural estimates of point-wise RGC density were obtained from optical coherence tomography (OCT) scans. Structural and functional data from the young healthy cohort were used to estimate the parameters of a computational spatial summation model to generate a template. The template was fitted with a Bayesian hierarchical model to estimate the latent RGC density in patients with glaucoma and age-matched controls. We tested two alternative hypotheses: fitting the data by translating the template horizontally (H1: change in RA) or vertically (H2: loss of sensitivity without a change in RA). Root mean squared error (RMSE) of the model fits to perimetric sensitivity were compared. Ninety-five percent confidence intervals were bootstrapped. The dynamic range of the functional and structural RGC density estimates was denoted by their 1st and 99th percentiles. RESULTS: The RMSE was 2.09 (95% CI = 1.92-2.26) under H1 and 2.49 (95% CI = 2.24-2.72) under H2 (P < 0.001). The average dynamic range for the structural RGC density estimates was only 11% that of the functional estimates. CONCLUSIONS: Macular sensitivity loss in glaucoma is better described by a model in which RA changes with RGC loss. Structural measurements have limited dynamic range.