静脉荧光素眼底血管造影与自适应光学成像在糖尿病视网膜病变中的关联:一项前瞻性病例系列
该前瞻性病例系列在加拿大多伦多单中心连续纳入9例糖尿病视网膜病变患者,于2020至2021年用RTX1相机在2°和4°视网膜偏心度行自适应光学成像,并用基于人工智能的RETICAD系统从静脉荧光素眼底血管造影提取同一位置的血流、灌注和血-视网膜屏障通透性。结果显示自适应光学测量的感光细胞间距与血-视网膜屏障通透性(r=0.303,P=0.027)及灌注(r=0.272,P=0.049)呈显著正相关;分层分析中感光细胞分散度与二者亦呈显著正相关,视锥细胞密度与血-视网膜屏障通透性呈负相关(r=-0.819,P=0.046)。作者结论认为自适应光学感光细胞间距与静脉荧光素眼底血管造影参数显著相关,未来需更大样本研究。
要点
- 9例糖尿病视网膜病变患者中,自适应光学感光细胞间距与静脉荧光素眼底血管造影的血-视网膜屏障通透性(r=0.303,P=0.027)及灌注(r=0.272,P=0.049)呈显著正相关。
- 按位置分层后,感光细胞分散度与血-视网膜屏障通透性(r=0.770,P=0.043)及灌注(r=0.846,P=0.034)呈显著正相关。
- 视锥细胞密度与血-视网膜屏障通透性呈负相关(r=-0.819,P=0.046)。
核心结论
- 在糖尿病视网膜病变患者中,自适应光学测量的感光细胞间距与静脉荧光素眼底血管造影测量的血-视网膜屏障通透性和灌注显著相关。
- 作者指出未来需要更大样本量的研究来理解不同患者群体中自适应光学与静脉荧光素眼底血管造影参数之间的关系。
研究设计与样本
- 前瞻性病例系列,连续纳入2020至2021年加拿大多伦多单中心收治的9例年龄大于18岁的糖尿病视网膜病变患者。
- 自适应光学成像采用RTX1相机(Imagine Eyes,Orsay,法国)在2°和4°视网膜偏心度进行。
- 静脉荧光素眼底血管造影采用基于人工智能的RETICAD系统提取同一视网膜位置的血流、灌注和血-视网膜屏障通透性。
- 自适应光学与静脉荧光素眼底血管造影参数之间的相关性采用Pearson相关系数计算。
主要发现
- 9例患者中,自适应光学感光细胞间距与静脉荧光素眼底血管造影的血-视网膜屏障通透性呈显著正相关(r=0.303,P=0.027)。
- 9例患者中,自适应光学感光细胞间距与静脉荧光素眼底血管造影的灌注呈显著正相关(r=0.272,P=0.049)。
- 按位置分层后,感光细胞分散度与血-视网膜屏障通透性呈显著正相关(r=0.770,P=0.043)。
- 按位置分层后,感光细胞分散度与灌注呈显著正相关(r=0.846,P=0.034)。
- 视锥细胞密度与血-视网膜屏障通透性呈负相关(r=-0.819,P=0.046)。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 作者指出未来需要更大样本量的研究来理解不同患者群体中自适应光学与静脉荧光素眼底血管造影参数之间的关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To our knowledge, we present the first case series investigating the relationship between adaptive optics (AO) imaging and intravenous fluorescein angiography (IVFA) parameters in patients with diabetic retinopathy. METHODS: Consecutive patients with diabetic retinopathy older than age 18 years presenting to a single center in Toronto, Canada, from 2020 to 2021 were recruited. Adaptive optics was performed with the RTX1 camera (Imagine Eyes, Orsay, France) at retinal eccentricities of 2° and 4°. Intravenous fluorescein angiography was assessed with the artificial intelligence-based RETICAD system to extract blood flow, perfusion, and blood-retinal-barrier (BRB) permeability at the same retinal locations. Correlations between AO and IVFA parameters were calculated using Pearson's correlation coefficient. RESULTS: Across nine cases, a significant positive correlation existed between photoreceptor spacing on AO and BRB permeability (r = 0.303, P = 0.027), as well as perfusion (r = 0.272, P = 0.049) on IVFA. When stratified by location, a significant positive correlation between photoreceptor dispersion and both BRB permeability and perfusion (r = 0.770, P = 0.043; r = 0.846, P = 0.034, respectively) was observed. Cone density was also negatively correlated with BRB permeability (r = -0.819, P = 0.046). CONCLUSION: Photoreceptor spacing on AO was significantly correlated with BRB permeability and perfusion on IVFA in patients with diabetic retinopathy. Future studies with larger sample sizes are needed to understand the relationship between AO and IVFA parameters in diverse patient populations.