采用扫频源光学相干断层扫描血管成像对镰状细胞病微血管变化的纵向分析
研究对30只镰状细胞病眼和12只年龄、种族匹配的对照眼间隔6年使用同一成像方案(包括超广角血管造影、扫频源OCT和3×3mm光学相干断层扫描血管成像)检查。结果显示镰状细胞病眼平均中心凹无血管区(FAZ)显著增大(P<0.01),浅层和深层毛细血管丛的中心凹区(直径1.5mm圆内)及颞侧血管密度(VD)降低(P<0.01),而旁中心凹区(直径1.5mm与3mm两圆之间的环)及上、下、鼻侧象限VD无变化。对照组FAZ大小和VD随时间无变化。
要点
- 镰状细胞病眼6年间平均FAZ显著增大(P<0.01),浅层和深层毛细血管丛中心凹区及颞侧VD降低(P<0.01)。
- 旁中心凹区及上、下、鼻侧象限VD未见随时间变化。
- 随访期间除1只眼出现海扇样新生血管外,未见周边视网膜病变进展;对照眼FAZ和VD无变化。
核心结论
- 镰状细胞病患者的纵向OCT血管成像显示FAZ扩大及颞侧和中心凹周围区域VD降低,尽管周边视网膜病变无进展,提示黄斑非灌注随时间加重。
研究设计与样本
- 纵向观察性研究,纳入镰状细胞病患者30只眼和年龄、种族匹配的未受累对照者12只眼,间隔6年使用同一成像方案(超广角血管造影、扫频源OCT和3×3mm光学相干断层扫描血管成像)检查,并在ImageJ软件上按既往报道的算法测量黄斑VD和FAZ。
主要发现
- 镰状细胞病眼平均FAZ显著增大(P<0.01),浅层和深层毛细血管丛的中心凹区(直径1.5mm圆内)及颞侧VD降低(P<0.01)。
- 镰状细胞病眼旁中心凹区(直径1.5mm与3mm两圆之间的环)及上、下、鼻侧象限VD随时间无变化。
- 随访期间除1只眼出现海扇样新生血管外,队列中未见周边视网膜病变加重。
- 对照眼FAZ大小和VD随时间无变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To analyze the changes in macular vascular densities (VDs) and foveal avascular zone (FAZ) over a 6-year period using swept-source optical coherence tomography angiography in patients with sickle cell disease compared with unaffected control subjects. METHODS: Thirty eyes of patients with sickle cell disease and 12 eyes of unaffected control subjects matched for age and ethnicity were examined at a 6-year interval using the same imaging protocol, including ultra-wide-field angiography, swept-source OCT, and 3 × 3-mm optical coherence tomography angiography. The macular VD and FAZ were measured on ImageJ software according to previously reported algorithms. RESULTS: In sickle cell eyes, the mean FAZ significantly increased ( P < 0.01), and the VD decreased in the foveal (within a circle of 1.5 mm in diameter around the foveal center) and temporal areas in both the superficial and the deep capillary plexuses ( P < 0.01). The VD did not change over time in the parafoveal area (annulus between two circles of 1.5 and 3 mm in diameter) and in the superior, inferior, and nasal sectors. No worsening of peripheral retinopathy was observed in the cohort during the follow-up, except for one eye that developed sea-fan. In the control eyes, no microvascular change was observed over time in FAZ size and VD. CONCLUSION: These longitudinal optical coherence tomography angiography findings in patients with sickle cell disease showed an enlargement of the FAZ and a decrease in VD in the temporal and perifoveal regions despite the absence of progression of peripheral retinopathy, suggesting a worsening of the macular nonperfusion over time in sickle cell disease.
引用
- Enjalbert A, Giocanti-Auregan A, Fajnkuchen F, et al. LONGITUDINAL ANALYSIS OF MICROVASCULAR CHANGES IN SICKLE CELL DISEASE USING SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY. Retina. 2024. PMID: 38029421. doi:10.1097/IAE.0000000000004013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。