文献速递小儿眼科与斜弱视

屈光参差性弱视视力治愈后抑制性暗点与立体视锐度的关系

Relationship Between Suppression Scotomas and Stereoacuity in Anisometropic Amblyopia With Successfully Treated Visual Acuity.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2023-01-01

本研究纳入103例无斜视且视力已成功治愈的屈光参差性弱视患者,用偏振四点(P4D)测试测量抑制性暗点大小,Randot立体视测试测量立体视锐度,并按4ΔBOT结果分为正常、亚正常和异常三组。结果显示三组间抑制性暗点水平直径和立体视锐度均有显著差异,抑制性暗点大小与立体视锐度强相关(r=0.732,P<0.0001)。

要点

  • P4D测得的抑制性暗点水平直径在4ΔBOT正常组、亚正常组和异常组间均有显著差异(P<0.0001)。
  • 三组立体视锐度对数均值分别为1.07(24.95″)、1.22(38.84″)和1.47(82.79″),组间均有显著差异(P<0.0001)。
  • 抑制性暗点水平直径与立体视锐度强相关(r=0.732,P<0.0001)。

核心结论

  • P4D测得的抑制性暗点大小与立体视锐度及4ΔBOT结果显著相关。

研究设计与样本

  • 纳入103例无斜视且视力已成功治愈的屈光参差性弱视患者。
  • 立体视锐度用Randot立体视测试测量,抑制性暗点大小用新型偏振四点(P4D)测试测量。
  • 根据4ΔBOT结果分为正常组(A组=29例)、亚正常组(B组=48例)和异常组(C组=26例)。
  • 比较三组抑制性暗点水平直径及以20秒弧(″)为底的对数立体视锐度。

主要发现

  • P4D测试时平均年龄为8.4±2.1岁。
  • A、B、C组抑制性暗点平均水平直径分别为0.35±0.79Δ、2.01±0.82Δ和5.50±2.72Δ,组间均有显著差异(A vs B:P<0.0001;A vs C:P<0.0001;B vs C:P<0.0001;单因素方差分析)。
  • A、B、C组平均对数立体视锐度分别为1.07(24.95″)、1.22(38.84″)和1.47(82.79″),组间均有显著差异(A vs B:P<0.0001;A vs C:P<0.0001;B vs C:P<0.0001;单因素方差分析)。
  • 立体视锐度与抑制性暗点水平直径强相关(r=0.732,P<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate the relationship among suppression scotoma size, stereoacuity, and four-prism base-out test (4ΔBOT) results in anisometropic amblyopia with successfully treated visual acuity. METHODS: We included 103 cases of anisometropic amblyopia successfully treated for visual acuity without strabismus. Stereoacuity was measured using a Randot Stereotest. The size of the suppression scotomas was measured using a new device, the polarized four dot (P4D) test. This is a modification of the Worth 4 dot test (W4D) device. The patients were divided into three groups based on the 4ΔBOT results: normal (group A = 29 cases), subnormal (group B = 48 cases), and abnormal (group C = 26 cases) response groups. The horizontal diameter of the suppression scotomas and stereoacuity in logarithmic values with a base of 20 seconds of arc (″) were compared among the 3 groups. RESULTS: The mean age at P4D testing was 8.4 ± 2.1 years. The average horizontal diameters of the suppression scotomas were 0.35 ± 0.79Δ, 2.01 ± 0.82Δ, and 5.50 ± 2.72Δ in groups A, B, and C, respectively, showing significant differences (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). The average logarithmic stereoacuity were 1.07 (24.95″), 1.22 (38.84″), and 1.47 (82.79″) in groups A, B, and C, respectively, thereby showing significant differences between the groups (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). Stereoacuity and horizontal diameter of the suppression scotoma were strongly correlated (r = 0.732, P < 0.0001). CONCLUSIONS: The suppression scotoma size measured using P4D correlated significantly with stereoacuity and the 4ΔBOT results.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Hozumi K, Yagasaki T, Yokoyama Y, et al. Relationship Between Suppression Scotomas and Stereoacuity in Anisometropic Amblyopia With Successfully Treated Visual Acuity. Invest Ophthalmol Vis Sci. 2023. PMID: 37561448. doi:10.1167/iovs.64.11.16

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。