大型烧伤病房中羊膜移植治疗眼部史蒂文斯-约翰逊综合征/中毒性表皮坏死松解症的临床结局
回顾性分析2014年4月至2022年1月某烧伤中心43例(85眼)因严重眼部史蒂文斯-约翰逊综合征(SJS)、中毒性表皮坏死松解症(TEN)或SJS/TEN接受羊膜移植(AMT)的患者,比较冷冻保存AMT环与脱水AMT的结局。末次随访平均最佳矫正视力(BCVA)全部眼为20/33、冷冻AMT组20/30、脱水AMT组20/34,组间无显著差异;冷冻AMT组睑球粘连形成多于脱水AMT组(P<.05)。作者认为AMT可减轻长期并发症并改善视力,但回顾性设计限制结论,需进一步研究。
要点
- 43例(85眼)严重眼部SJS/TEN接受AMT,末次随访平均BCVA全部眼20/33。
- 冷冻AMT组平均BCVA 20/30 vs 脱水AMT组20/34,组间无显著差异。
- 冷冻AMT组睑球粘连形成多于脱水AMT组(P<.05)。
核心结论
- 作者认为,在严重眼部SJS/TEN中使用AMT可大幅减轻长期并发症并改善视力结局。
- 作者指出,本研究的回顾性性质限制了对不同AMT治疗方法结局差异作出实质性结论。
- 作者认为,冷冻保存AMT环与脱水AMT联合睑球粘连环的结局特征相似。
- 作者提出,需进一步研究评估最佳AMT技术。
研究设计与样本
- 回顾性、非随机干预研究,回顾性查阅2014年4月至2022年1月某烧伤中心43例(85眼)因严重眼部SJS、TEN或SJS/TEN接受AMT患者的病历。
- 比较冷冻保存AMT环(cryoAMT)与脱水AMT(deAMT)的使用。
主要发现
- 85眼中72眼接受deAMT联合睑球粘连环,13眼接受cryoAMT覆盖角膜表面;所有患者均将deAMT置于睑缘和睑结膜并塞入穹窿。
- 末次随访平均BCVA全部眼为20/33、cryoAMT组为20/30、deAMT组为20/34,组间无显著差异。
- 最常见可疑致病药物为拉莫三嗪(占全部病例17%)。
- 平均长期并发症评分为1.4,cryoAMT组1.6 vs deAMT组1.4,组间无显著差异(P = .5)。
- cryoAMT组睑球粘连形成多于deAMT组(P < .05)。
关键数值与推荐
- 严重眼部SJS/TEN患者接受AMT,deAMT联合睑球粘连环或cryoAMT覆盖角膜表面。
- 平均长期并发症评分1.4,cryoAMT组1.6 vs deAMT组1.4(P = .5)。
- cryoAMT组睑球粘连形成多于deAMT组(P < .05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 作者指出,本研究的回顾性性质限制了对不同AMT治疗方法结局差异作出实质性结论。
- 作者提出,需进一步研究评估最佳AMT技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To analyze the clinical outcome of amniotic membrane transplantation in patients with ocular Stevens-Johnson syndrome/toxic epidermal necrolysis at a major burn unit. DESIGN: Retrospective, non-randomized interventional study. METHODS: A retrospective chart review from April 2014 to January 2022 of 43 patients (85 eyes) at a burn center who underwent amniotic membrane transplantation (AMT) for severe ocular Stevens-Johnson Syndrome (SJS), toxic epidermal necrolysis (TEN), or SJS/TEN was performed. Data regarding the clinical course and outcome were obtained. A comparison between the use of cryopreserved AMT rings (cryoAMT) and dehydrated AMT (deAMT) was also assessed. RESULTS: A total of 85 eyes in 43 patients underwent AMT for severe ocular SJS/TEN. Of the eyes, 72 received deAMT with symblepharon ring, whereas 13 received cryoAMT over the cornea surface. All patients had deAMT placed over the eyelid margins and palpebral conjunctivae and tucked into the fornices. The average best-corrected visual acuity (BCVA) on last follow-up examination was 20/33, 20/30, and 20/34 in all eyes, the cryoAMT group, and the deAMT group, respectively (no significant difference between groups). The most common suspected inciting agent was lamotrigine (17% of all cases). The average long-term complication score was 1.4, with no significant difference between the cryoAMT group (1.6) and the deAMT group (1.4, P = .5). Symblepharon formation was seen more in the cryoAMT group compared to the deAMT group (P < .05). CONCLUSION: The use of AMTs in severe ocular SJS/TEN greatly mitigates long-term complications and improves visual outcome. The retrospective nature of this study limits substantial conclusions regarding any significant difference in outcome between AMT treatment methods. Nevertheless, the use of cryopreserved AMT rings has a similar outcome profile compared to use of dehydrated AMTs with symblepharon ring. Further research is needed to evaluate optimal AMT techniques.
引用
- Mortensen XM, Shenkute NT, Zhang AY, et al. Clinical Outcome of Amniotic Membrane Transplant in Ocular Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis at a Major Burn Unit. Am J Ophthalmol. 2023. PMID: 37598739. doi:10.1016/j.ajo.2023.07.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。