文献速递青光眼

暗光与明光下测量的静态与动态眼部生物特征作为房角关闭进展危险因素的作用

Role of Static and Dynamic Ocular Biometrics Measured in the Dark and Light as Risk Factors for Angle Closure Progression.
PubMed 文献 · Am J Ophthalmol · 2023-08-06

本研究基于中山房角关闭预防试验中未治疗对照眼的数据,回顾性分析861只眼在暗光与明光下测量的静态与动态眼部生物特征对原发性可疑房角关闭(PACS)进展为原发性房角关闭(PAC)的预测作用。多变量模型显示年龄较大、眼压较高及明光下TISA500较小与进展风险显著相关,明光下静态参数预测价值不低于暗光下测量。

要点

  • 明光下TISA500每减小0.01 mm²,进展风险HR=1.28(P≤.04)。
  • 明光下TISA500最低四分位眼进展风险HR=4.56,高于暗光下HR=2.89。
  • 动态变化参数与进展无显著关联(P≥.08)。

核心结论

  • 明光下测量的静态参数对房角关闭进展的预测能力与暗光下测量相当,甚至可能更强。
  • 明光与暗光条件下测量的眼部生物特征可能为房角关闭进展的风险分层提供额外信息。

研究设计与样本

  • 回顾性队列研究,使用前瞻性随机对照试验中未治疗对照眼的数据。
  • 中山房角关闭预防试验受试者在暗光与明光下接受前节光学相干断层扫描(AS-OCT)成像。
  • 测量静态生物特征参数(包括房角、虹膜、晶状体及前房参数),动态变化参数由暗光测量值减去明光测量值计算。
  • 采用Cox比例风险回归模型评估房角关闭进展的危险因素。
  • 共分析861只眼(861名受试者),其中36只眼进展。

主要发现

  • 单变量分析中,明光与暗光下TISA500测量值与进展相关(P < .001),动态变化参数与进展无显著关联(P ≥ .08)。
  • 主多变量模型中,年龄较大(HR=1.09/年)、眼压较高(HR=1.13/mm Hg)及明光下TISA500较小(HR=1.28/0.01 mm²)与进展风险显著相关(P ≤ .04)。
  • 以暗光TISA500替换明光TISA500时,暗光TISA500同样显著(HR=1.28,P = .002)。
  • 明光下TISA500最低四分位眼的进展风险(HR=4.56,P < .001)较暗光测量(HR=2.89,P = .003)更具预测性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the role of static and dynamic ocular biometric parameters measured in the dark and light for predicting progression of primary angle closure suspect (PACS) to primary angle closure (PAC). DESIGN: Retrospective cohort study using prospective randomized controlled trial data from untreated, control eyes. METHODS: Zhongshan Angle Closure Prevention Trial subjects underwent anterior segment optical coherence tomography (AS-OCT) imaging in the dark and light. Static biometric parameters were measured, consisting of angle, iris, lens, and anterior chamber parameters. Dynamic change parameters were calculated by subtracting light measurements from dark measurements. Cox proportional hazards regression models were developed to assess risk factors for PACD progression. RESULTS: A total of 861 eyes of 861 participants were analyzed (36 progressors). On univariable analysis, TISA500 measurements in the light and dark were associated with progression (P < .001), whereas dynamic change parameters were not (P ≥ .08). In the primary multivariable model, older age (hazard ratio [HR] = 1.09 per year), higher intraocular pressure (IOP) (HR = 1.13 per mm Hg), and smaller TISA500 in the light (HR = 1.28 per 0.01 mm2) were significantly associated with greater risk of progression (P ≤ .04). Dark TISA500 had similar significance (HR = 1.28, P = .002) when replacing light TISA500. Risk of progression was more predictive among eyes in the lowest quartile of light TISA500 measurements (HR = 4.56, P < .001) compared to dark measurements (HR = 2.89, P = .003). CONCLUSION: Static parameters measured in the light are as predictive, and possibly more so, of angle closure progression as those measured in the dark. Ocular biometrics measured under light and dark conditions may provide additional information for risk-stratifying patients for angle closure progression.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Cho A, Xu BY, Friedman DS, et al. Role of Static and Dynamic Ocular Biometrics Measured in the Dark and Light as Risk Factors for Angle Closure Progression. Am J Ophthalmol. 2023. PMID: 37549818. doi:10.1016/j.ajo.2023.07.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。