房角切开术范围对原发性开角型青光眼治疗安全性和有效性的影响:一项多中心研究
这项多中心回顾性非随机比较研究纳入231例患者308只眼,比较120度、240度、360度房角切开术(GT)联合或不联合超声乳化联合人工晶状体植入(PEI)治疗原发性开角型青光眼(POAG)的疗效与安全性。结果显示,无论是否联合PEI,三种范围GT在降低眼压和减少用药数量以及完全与合格成功率方面均无显著差异;360GT组前房积血比例最高。结论认为120GT联合或不联合PEI足以治疗伴或不伴白内障的POAG。
要点
- 120GT、240GT、360GT联合或不联合PEI在降低眼压和减少用药数量方面疗效相似。
- 三组独立GT和PEI+GT在完全与合格成功率的累积生存概率方面无显著差异。
- 360GT联合或不联合PEI较120GT或240GT更易导致前房积血。
核心结论
- 120GT、240GT和360GT联合或不联合PEI在降低POAG患者眼压和减少用药数量方面显示出相似疗效。
- 与120GT或240GT相比,360GT联合或不联合PEI更可能引起前房积血。
- 120GT联合或不联合PEI足以治疗伴或不伴白内障的POAG。
研究设计与样本
- 多中心、回顾性、比较性、非随机干预研究,纳入诊断为POAG并接受GT联合或不联合PEI的患者。
- 共纳入231例患者308只眼,平均随访14.4±8.6个月(范围6.0-48.0个月)。
- 患者分为6组:独立120GT、独立240GT、独立360GT、PEI+120GT、PEI+240GT、PEI+360GT。
- 收集并比较眼压、降眼压药物数量及并发症数据。
- 成功定义为术后眼压6至18 mm Hg且较基线降低20%且无需进一步青光眼手术;完全成功和合格成功分别定义为上述标准下无需和需要降眼压药物。
主要发现
- 三组独立GT和PEI+GT在眼压降低、用药数量减少以及完全与合格成功率的累积生存概率方面均无显著差异。
- 360GT组联合或不联合PEI的前房积血比例最高。
关键数值与推荐
- 成功标准为术后眼压6至18 mm Hg且较基线降低20%且无需进一步青光眼手术。
- 完全成功和合格成功分别定义为上述标准下无需和需要降眼压药物。
临床怎么用
- 原文结论认为120GT联合或不联合PEI足以治疗伴或不伴白内障的POAG。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the efficacy and safety of 120-, 240-, and 360-degree goniotomy (GT) with or without phacoemulsification with intraocular lens implantation (PEI) for patients with primary open-angle glaucoma (POAG). DESIGN: Multicenter, retrospective, comparative, nonrandomized interventional study. METHODS: Patients diagnosed with POAG who underwent GT with or without PEI were included, and divided into 6 groups: 1) standalone 120-degree GT (120GT); 2) standalone 240-degree GT (240GT); 3) standalone 360-degree GT (360GT); 4) PEI + 120GT; 5) PEI + 240GT; and 6) PEI + 360GT. Data on intraocular pressure (IOP), the number of ocular hypotensive medications, and complications were collected and compared. Success was defined as a postoperative IOP within the range of 6 to 18 mm Hg and a 20% reduction from baseline without further glaucoma surgery. Complete success and qualified success were defined as the above without and with ocular hypotensive medications, respectively. RESULTS: Three hundred eight eyes of 231 patients were included with a mean follow-up of 14.4 ± 8.6 months (6.0-48.0 months). There were no significant differences in the reductions in IOP and number of medications and cumulative survival probability for complete and qualified success rates among the 3 groups of standalone GT and PEI + GT. The 360GT group had the highest proportion of hyphema with or without PEI. CONCLUSIONS: 120GT, 240GT, and 360GT with or without PEI showed similar efficacy in reducing IOP and medications used in POAG. 360GT with or without PEI was more likely to cause hyphema compared with 120GT or 240GT. 120GT with or without PEI was sufficient for treating POAG with or without cataract.</ABSTRACT>.
引用
- Zhang Y, Yu P, Zhang Y, et al. Influence of Goniotomy Size on Treatment Safety and Efficacy for Primary Open-Angle Glaucoma: A Multicenter Study. Am J Ophthalmol. 2023. PMID: 37573988. doi:10.1016/j.ajo.2023.08.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。