文献速递小儿眼科与斜弱视

先天性上斜肌麻痹中Guyton增强牵拉试验与旋转牵拉试验的特征

[Characteristics of Guyton's exaggerated forced duction test (FDT) and torsional FDT in congenital superior oblique palsy].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2023-01-01

横断面研究纳入42例(84只眼)单眼先天性上斜肌麻痹(CSOP)和间歇性外斜视(IXT)患者,术中行Guyton增强牵拉试验(FDT)和旋转FDT评估上斜肌松弛程度。结果显示两种FDT在麻痹眼、非麻痹眼和IXT眼间差异有统计学意义,且与上斜肌最大横截面积(max-CSA)相关,但与垂直和旋转斜视度数无相关性。

要点

  • Guyton增强FDT测得麻痹眼、非麻痹眼和IXT眼上斜肌松弛程度分别为-2.52±1.20、-0.35±0.71和-0.03±0.16级,差异有统计学意义(F=88.10,P<0.001)。
  • 旋转FDT测得麻痹眼、非麻痹眼和IXT眼外旋角度分别为48.70°±9.67°、37.39°±5.40°和38.95°±2.88°,差异有统计学意义(F=16.67,P<0.001)。
  • Guyton增强FDT分级与旋转FDT外旋角度呈负相关(r=-0.64,P=0.001),但与垂直斜视度数(r=-0.12,P=0.579;r=0.33,P=0.126)和FDA(r=-0.02,P=0.921;r=-0.23,P=0.309)无相关性。

核心结论

  • Guyton增强FDT和旋转FDT均可评价CSOP患者的上斜肌松弛程度,且二者与上斜肌形态变化具有相关性,但FDT不能反映患者的垂直和旋转斜视度数。

研究设计与样本

  • 横断面研究,纳入2021年9月至2022年3月于天津市眼科医院拟行斜视矫正手术的单眼CSOP患者和IXT患者,共42例(84只眼),其中IXT患者19例(38只眼),CSOP患者23例(46只眼,麻痹眼和非麻痹眼各23只眼)。

主要发现

  • Guyton增强FDT测得麻痹眼、非麻痹眼和IXT眼上斜肌松弛程度分别为(-2.52±1.20)、(-0.35±0.71)和(-0.03±0.16)级,差异有统计学意义(F=88.10,P<0.001)。
  • 旋转FDT测得麻痹眼、非麻痹眼和IXT眼外旋角度分别为48.70°±9.67°、37.39°±5.40°和38.95°±2.88°,差异有统计学意义(F=16.67,P<0.001);内旋角度差异无统计学意义(F=2.36,P=0.100)。
  • IXT患者与CSOP患者FDA分别为-12.11°±7.42°和-19.02°±4.95°,CSOP患者麻痹眼与非麻痹眼上斜肌max-CSA分别为(7.59±4.69)mm²和(11.63±3.64)mm²,差异均有统计学意义(均P<0.001)。
  • Guyton增强FDT分级与旋转FDT外旋角度呈负相关(r=-0.64,P=0.001),与上斜肌max-CSA呈正相关(r=0.45,P=0.030),旋转FDT外旋角度与max-CSA呈负相关(r=-0.52,P=0.011)。
  • Guyton增强FDT和旋转FDT与垂直斜视度数(r=-0.12,P=0.579;r=0.33,P=0.126)和FDA(r=-0.02,P=0.921;r=-0.23,P=0.309)均无相关性。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the characteristics of Guyton's exaggerated forced duction test (FDT) and torsional FDT in patients with congenital superior oblique palsy (CSOP) and their correlation with clinical features. Methods: This cross-sectional study included single-eye CSOP patients and intermittent exotropia (IXT) patients scheduled for strabismus correction surgery at Tianjin Eye Hospital from September 2021 to March 2022. Prior to surgery, measurements of fovea-disc angle (FDA) and maximum cross-sectional area of the superior oblique muscle (max-CSA) were obtained in both eyes of the patients. The Guyton's exaggerated FDT and torsional FDT were performed intraoperatively to assess the degree of superior oblique muscle relaxation. The characteristics of the two FDT tests and their correlation with vertical strabismus angle, FDA, and max-CSA were analyzed. Statistical analyses were conducted using t-test, ANOVA, Tukey's test, Mann-Whitney U test, and chi-square test. Results: A total of 42 patients (84 eyes) were included in the study, including 19 IXT patients (38 eyes) and 23 CSOP patients (46 eyes, 23 eyes with palsy and 23 eyes without palsy). There were no statistically significant differences in gender composition or age between the IXT and CSOP patients (all P>0.05). The degrees of superior oblique muscle relaxation measured by the Guyton's exaggerated FDT were (-2.52±1.20), (-0.35±0.71), and (-0.03±0.16) for the palsy eye, non-palsy eye, and IXT eyes, respectively, showing significant differences (F=88.10, P<0.001). The torsional FDT measurements yielded external rotation angles of 48.70°±9.67°, 37.39°±5.40°, and 38.95°±2.88° for the palsy eye, non-palsy eye, and IXT eyes, respectively, showing significant differences (F=16.67, P<0.001). There was no statistically significant difference in internal rotation angles (F=2.36, P=0.100). The FDA values were-12.11°±7.42° for IXT patients and-19.02°±4.95° for CSOP patients, while the max-CSA values for the palsy eye and non-palsy eye of CSOP patients were (7.59±4.69) mm² and (11.63±3.64) mm², respectively, all showing significant differences (all P<0.001). The degree of superior oblique muscle tendon relaxation assessed by the Guyton's exaggerated FDT was negatively correlated with the external rotation angle measured by the torsional FDT (r=-0.64, P=0.001). They were positively correlated with max-CSA (r=0.45, P=0.030) and negatively correlated with max-CSA (r=-0.52, P=0.011). However, there was no correlation with vertical and rotational strabismus angle (r=-0.12, P=0.579; r=0.33, P=0.126) and FDA (r=-0.02, P=0.921; r=-0.23, P=0.309). Conclusions: Guyton's exaggerated FDT and torsional FDT can both assess the degree of superior oblique muscle relaxation in patients with CSOP. Furthermore, these two tests are correlated with changes in superior oblique muscle morphology. However, FDT cannot reflect the degree of vertical and rotational strabismus in patients. 目的: 探讨先天性上斜肌麻痹(CSOP)患者上斜肌Guyton增强牵拉试验(FDT)和眼球旋转FDT的特征其与患者临床特征的相关性。 方法: 横断面研究。纳入2021年9月至2022年3月于天津市眼科医院拟行斜视矫正手术的单眼CSOP患者和间歇性外斜视(IXT)患者。术前测量患者双眼黄斑中心凹-视盘几何中心夹角(FDA)及上斜肌最大横截面积(max-CSA)术中双眼行Guyton增强FDT和旋转FDT,对上斜肌松弛程度进行评价和比较。分析两种FDT的特征及其与垂直斜视度数、FDA、max-CSA的相关性。采用t检验、ANOVA检验、Tukey、Mann-Whitney U检验和χ2检验进行统计学分析。 结果: 纳入患者共42例(84只眼),其中IXT患者19例(38只眼),男10例,女9例,年龄7(7,8)岁;CSOP患者23例(46只眼,麻痹眼和非麻痹眼各23只眼),男13例,女10例,年龄8(4,8)岁。IXT和CSOP患者性别构成和年龄差异均无统计学意义(均P>0.05)。Guyton增强FDT测得CSOP患者麻痹眼、非麻痹眼和IXT患者双眼上斜肌松弛程度分别为(-2.52±1.20)、(-0.35±0.71)和(-0.03±0.16)级,差异有统计学意义(F=88.10,P<0.001)。旋转FDT测得CSOP患者麻痹眼、非麻痹眼和IXT患者双眼的眼球外旋角度分别为48.70°±9.67°、37.39°±5.40°和38.95°±2.88°,差异有统计学意义(F=16.67,P<0.001),内旋角度差异无统计学意义(F=2.36,P=0.100)。IXT患者与CSOP患者FDA分别为-12.11°±7.42°和-19.02°±4.95°,CSOP患者麻痹眼与非麻痹眼上斜肌max-CSA分别为(7.59±4.69)和(11.63±3.64)mm2,差异均有统计学意义(均P<0.001)。Guyton增强FDT测得上斜肌肌腱松弛程度分级与旋转FDT测得外旋角度呈负相关(r=-0.64,P=0.001),二者与上斜肌max-CSA分别呈正相关(r=0.45,P=0.030)和负相关(r=-0.52,P=0.011),但与垂直斜视度数(r=-0.12,P=0.579;r=0.33,P=0.126)和FDA(r=-0.02,P=0.921;r=-0.23,P=0.309)均无相关性。 结论: Guyton增强 FDT和旋转FDT均可评价先天性上斜肌麻痹患者的上斜肌松弛程度,且二者与上斜肌形态变化具有相关性,但FDT不能反映患者的垂直和旋转斜视度数。.

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Li YP, Chen HR, Gu SY, et al. [Characteristics of Guyton's exaggerated forced duction test (FDT) and torsional FDT in congenital superior oblique palsy]. Zhonghua Yan Ke Za Zhi. 2023. PMID: 37408424. doi:10.3760/cma.j.cn112142-20230417-00153

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。