使用频域和扫频源光学相干断层扫描分析视神经乳头深部结构
该研究纳入12例开角型青光眼患者,分别用频域OCT(以Bruch膜开口为中心24条放射状B扫描)和扫频源OCT(水平及垂直光栅扫描各5线)成像,由3名独立观察者盲法判断深部视神经乳头结构可检测性。两种OCT观察者间一致性均高,扫频源OCT总体检出率有更高趋势但差异未达统计学显著,仅鼻侧象限后部筛板插入检出率有统计学差异。
要点
- 扫频源OCT与频域OCT观察者间一致性均高(组内相关系数分别为0.81-0.93和0.77-0.82)。
- 扫频源OCT对深部视神经乳头结构总体检出率有更高趋势,但差异未达统计学显著。
- 仅鼻侧象限后部筛板插入检出率有统计学差异,扫频源OCT为13/36,频域OCT为6/36(p=0.04)。
核心结论
- 总体而言,扫频源OCT与频域OCT对深部视神经乳头结构的可视化程度在统计学上相当,但扫频源OCT有更高可视化率的趋势。
研究设计与样本
- 研究纳入12例开角型青光眼患者,分别接受频域OCT(以Bruch膜开口为中心24条放射状B扫描)和扫频源OCT(以视神经乳头为中心水平及垂直光栅扫描各5线)成像。
- 从两种模态中选取最佳匹配的水平及垂直扫描图像,由3名独立观察者盲法判断Bruch膜开口、脉络膜后表面、前部巩膜管开口及筛板前部和后部插入巩膜是否可检测。
主要发现
- 扫频源OCT和频域OCT观察者间一致性均高,组内相关系数分别为0.81-0.93和0.77-0.82。
- 扫频源OCT总体检出率有更高趋势,但差异未达统计学显著。
- 鼻侧象限后部筛板插入检出率在扫频源OCT为13/36,频域OCT为6/36(p=0.04),为唯一有统计学差异的结构。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Histological evidence indicates that the earliest structural changes to the optic nerve head (ONH) in glaucoma occur in the lamina cribrosa (LC) and its interface with the sclera. However, clinical imaging of these structures remains challenging. We compared the visibility of deep ONH structures with newer iterations of spectral-domain (SD) and swept-source (SS) optical coherence tomography (OCT). METHODS: Twelve patients with open-angle glaucoma were imaged with SD-OCT with 24 radial B-scans centred on Bruch's membrane opening (BMO) and SS-OCT with a horizontal and vertical raster scan pattern containing five lines each, centred on the ONH. Single best-matched horizontal and vertical scans from the two modalities were selected and exported. Three independent observers masked to modality determined if BMO, posterior choroid surface, anterior scleral canal opening and anterior and posterior LC insertions into the sclera were detectable in the matched B-scan images. We determined the interobserver agreement and concordance in detecting each structure with the two OCT imaging modalities. RESULTS: There was a high interobserver agreement with both SS-OCT and SD-OCT (inter-item correlations: 0.81-0.93 and 0.77-0.82, respectively). There was a consistent tendency for higher overall detection rates with SS-OCT, however, the differences failed to reach statistical significance. With respect to individual structures, only the posterior LC insertion in the nasal quadrant was statistically different, with a detection rate of 13 and 6 (pooled out of a total of 36 across the three observers) with SS-OCT and SD-OCT, respectively (p=0.04). CONCLUSION: Overall, both SS-OCT and SD-OCT showed statistically equivalent visualisation of ONH structures, however, SS-OCT tended to have higher visualisation rates.
引用
- Darwich R, Jarrar F, Syed M, et al. Analysis of deep optic nerve head structures with spectral domain and swept-source optical coherence tomography. Br J Ophthalmol. 2024. PMID: 37507129. doi:10.1136/bjo-2023-323222
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。