文献速递青光眼眼底病与葡萄膜炎

用于在中国人群中检测近视性青光眼的高近视视盘周围视网膜神经纤维层厚度正常值数据库

High Myopia Normative Database of Peripapillary Retinal Nerve Fiber Layer Thickness to Detect Myopic Glaucoma in a Chinese Population.
PubMed 文献 · Ophthalmology · 2023-07-26

该横断面多中心研究基于4个中心1367名中国受试者(2325眼)建立高近视特异性视盘周围视网膜神经纤维层厚度正常值数据库,并在内部和外部验证集中评估其区分高近视与高近视性青光眼的效能。以全局pRNFL厚度第5百分位为阈值时,内部验证集准确度为0.93(95%CI 0.90-0.95),外部验证集为0.85(95%CI 0.81-0.89),敏感度和特异度均较高。该数据库检测高近视性青光眼的能力优于SS OCT内置数据库(P < 0.001)。

要点

  • 高近视特异性pRNFL正常值数据库在内部验证集检测高近视性青光眼的准确度为0.93(95%CI 0.90-0.95)。
  • 以全局pRNFL厚度第5百分位为阈值,内部和外部验证集敏感度均为0.75,特异度均为1.00。
  • 该数据库的敏感度和特异度均高于SS OCT内置数据库的相应百分位阈值(P < 0.001)。

核心结论

  • 高近视特异性正常值数据库比SS OCT内置数据库更能检测高近视性青光眼,可能成为鉴别高近视性青光眼与高近视的有效工具。

研究设计与样本

  • 横断面多中心研究,纳入4个中心1367名中国受试者(2325眼),均为非病理性高近视或高近视性青光眼。
  • 质控后,694名受试者的1108眼(高近视)纳入正常值数据库;内部验证集纳入408名受试者的459眼(高近视323眼、高近视性青光眼136眼)。
  • 外部验证集纳入197名受试者的322眼(高近视131眼、高近视性青光眼191眼)。
  • 仅纳入眼压>21 mmHg的高近视性青光眼眼。
  • 采用SS OCT测量pRNFL厚度,检验全局和象限pRNFL厚度低于正常值数据库最低第5百分位或最低第1百分位的四种策略。

主要发现

  • 以全局pRNFL厚度第5百分位为阈值,内部验证集检测高近视性青光眼的准确度为0.93(95%CI 0.90-0.95),外部验证集为0.85(95%CI 0.81-0.89)。
  • 以第1百分位为阈值,内部验证集准确度为0.85(95%CI 0.81-0.88),外部验证集为0.70(95%CI 0.65-0.75)。
  • 全局pRNFL厚度第5百分位在内部验证集敏感度为0.75(95%CI 0.67-0.82)、特异度为1.00(95%CI 0.99-1.00),在外部验证集敏感度为0.75(95%CI 0.68-0.81)、特异度为1.00(95%CI 0.97-1.00)。
  • 与OCT设备内置数据库相比,高近视特异性正常值数据库在pRNFL厚度低于第5或第1百分位时敏感度和特异度均更高(P < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To develop and validate the performance of a high myopia (HM)-specific normative database of peripapillary retinal nerve fiber layer (pRNFL) thickness in differentiating HM from highly myopic glaucoma (HMG). DESIGN: Cross-sectional multicenter study. PARTICIPANTS: A total of 1367 Chinese participants (2325 eyes) with nonpathologic HM or HMG were included from 4 centers. After quality control, 1108 eyes from 694 participants with HM were included in the normative database; 459 eyes from 408 participants (323 eyes with HM and 136 eyes with HMG) and 322 eyes from 197 participants (131 eyes with HM and 191 eyes with HMG) were included in the internal and external validation sets, respectively. Only HMG eyes with an intraocular pressure > 21 mmHg were included. METHODS: The pRNFL thickness was measured with swept-source (SS) OCT. Four strategies of pRNFL-specified values were examined, including global and quadrantic pRNFL thickness below the lowest fifth or the lowest first percentile of the normative database. MAIN OUTCOMES MEASURES: The accuracy, sensitivity, and specificity of the HM-specific normative database for detecting HMG. RESULTS: Setting the fifth percentile of the global pRNFL thickness as the threshold, using the HM-specific normative database, we achieved an accuracy of 0.93 (95% confidence interval [CI], 0.90-0.95) and 0.85 (95% CI, 0.81-0.89), and, using the first percentile as the threshold, we acheived an accuracy of 0.85 (95% CI, 0.81-0.88) and 0.70 (95% CI, 0.65-0.75) in detecting HMG in the internal and external validation sets, respectively. The fifth percentile of the global pRNFL thickness achieved high sensitivities of 0.75 (95% CI, 0.67-0.82) and 0.75 (95% CI, 0.68-0.81) and specificities of 1.00 (95% CI, 0.99-1.00) and 1.00 (95% CI, 0.97-1.00) in the internal and external validation datasets, respectively. Compared with the built-in database of the OCT device, the HM-specific normative database showed a higher sensitivity and specificity than the corresponding pRNFL thickness below the fifth or first percentile (P < 0.001 for all). CONCLUSIONS: The HM-specific normative database is more capable of detecting HMG eyes than the SS OCT built-in database, which may be an effective tool for differential diagnosis between HMG and HM. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Song Y, Li F, Chong RS, et al. High Myopia Normative Database of Peripapillary Retinal Nerve Fiber Layer Thickness to Detect Myopic Glaucoma in a Chinese Population. Ophthalmology. 2023. PMID: 37499953. doi:10.1016/j.ophtha.2023.07.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。