以黄斑厚度图评估渗出性年龄相关性黄斑变性的变化,作为远程患者监测的替代策略
本研究为回顾性比较性诊断分析,纳入53只渗出性年龄相关性黄斑变性眼共1385次影像会话,比较单独黄斑厚度图、单独黄斑中心凹B扫描及5张黄斑B扫描三种策略检测需全面临床评估的变化的能力。结果显示单独黄斑厚度图与共识基准的一致率最高(90.05%,SD 0.78%),其次为黄斑中心B扫描(87.87%,SD 1.59%)和5-B扫描法(86.512%,SD 0.64%)。作者认为单独黄斑厚度图可提供足够信息识别复发性渗出,可能足以用于远程监测。
要点
- 单独黄斑厚度图与共识基准的一致率最高,为90.05%(SD 0.78%)。
- 黄斑中心B扫描一致率为87.87%(SD 1.59%),5-B扫描法为86.512%(SD 0.64%)。
- 作者认为单独黄斑厚度图可能足以用于渗出性年龄相关性黄斑变性的远程监测。
核心结论
- 单独黄斑厚度图可提供足够信息以轻松识别渗出性年龄相关性黄斑变性患者的复发性渗出,这些图可能足以用于远程监测。
研究设计与样本
- 回顾性、比较性诊断分析,纳入53只渗出性年龄相关性黄斑变性眼,共1385次影像会话,使用黄斑中心6×6-mm光学相干断层扫描(CIRRUS HD-OCT 5000;Zeiss)成像。
主要发现
- 与共识基准比较,单独黄斑厚度图的平均一致率最高,为90.05%(SD 0.78%)。
- 黄斑中心B扫描的平均一致率为87.87%(SD 1.59%),5-B扫描法为86.512%(SD 0.64%)。
关键数值与推荐
- 评分者被告知两次扫描间隔2周,需判断是否存在需要全面临床评估的变化。
- 共识基准由评分者使用CIRRUS审阅站评估光学相干断层扫描扫描所含全部信息达成。
- 单独黄斑厚度图与共识基准的Fleiss kappa最高。
临床怎么用
- 作者认为单独黄斑厚度图可能足以用于渗出性年龄相关性黄斑变性患者的远程监测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine if macular thickness maps (MTMs) are sufficient to guide management of eyes with exudative age-related macular degeneration (eAMD), we compared the ability to detect change using MTMs with the ability to detect change using the entire optical coherence tomography (OCT) scan in patients undergoing therapy. DESIGN: Retrospective, comparative diagnostic analysis. METHODS: Patients with eAMD were imaged using macula-centered 6 × 6-mm OCT scans (CIRRUS HD-OCT 5000; Zeiss). In each case, graders were asked to determine if there were changes that warranted a full clinical assessment after viewing 2 consecutive scans using one of 3 different imaging strategies: MTMs alone, individual foveal-centered B scans alone, or 5 macular B scans including the foveal-centered B scan. Graders were told the 2 scans were taken 2 weeks apart. The consensus ground truth was reached by the graders using a CIRRUS review station to evaluate all the information contained within the OCT scans. RESULTS: A total of 53 eyes were included in this study with 1385 imaging sessions. The Fleiss kappa was highest when graders were given MTMs alone compared with the ground truth. When the averages of all 5 graders were compared with the ground truth, the MTMs alone showed the highest level of agreement (90.05%, SD 0.78%) followed by the central B scans (87.87%, SD 1.59%) and the 5-B scan method (86.512%, SD 0.64%). CONCLUSION: MTMs alone provide sufficient information to easily identify recurrent exudation in patients with eAMD, and these maps may be all that is needed for remote monitoring.
引用
- Trivizki O, Varcheie M, Bello S, et al. Assessing Change in Exudative Age-Related Macular Degeneration With Macular Thickness Maps as a Surrogate Strategy for Remote Patient Monitoring. Am J Ophthalmol. 2023. PMID: 37499893. doi:10.1016/j.ajo.2023.07.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。