泪道流出道阻塞中的泪腺活动:探索泪液分泌与流出之间的潜在交互作用
对连续单侧原发性获得性鼻泪管阻塞(PANDO)患者直接评估睑部泪腺活动,并检测OSDI、NIBUT、泪河高度和Schirmer I。PANDO侧泪腺泪液流率较对侧未受累眼显著降低(0.8 vs 0.99 µL/min;p=0.014),而NIBUT、Schirmer I、睑部泪腺大小和泪道开口数无显著差异。作者认为泪液流出与泪液产生机制间可能的沟通方式需进一步探索。
要点
- 单侧PANDO患者PANDO侧泪腺泪液流率较对侧未受累眼显著降低(0.8 vs 0.99 µL/min;p=0.014)。
- PANDO眼与非PANDO眼NIBUT(11.56 vs 11.58 s;p=0.49)和Schirmer I(18.83 vs 19.4 mm;p=0.313)无显著差异。
- 睑部泪腺大小(29.3 vs 28.6 mm2;p=0.41)和泪道开口数(中位数2 vs 2.5)在两眼间相似。
核心结论
- 单侧泪道流出道阻塞患者睑部泪腺的泪液流率较对侧未受累眼显著降低。
- 泪液流出与泪液产生机制之间可能的沟通方式需进一步探索。
研究设计与样本
- 对连续诊断为单侧原发性获得性鼻泪管阻塞(PANDO)的患者直接评估睑部泪腺活动。
- 同时检测眼表疾病指数(OSDI)、非侵入性泪膜破裂时间(NIBUT;Oculus K5M)、泪河高度和Schirmer I。
- 主要结局指标为PANDO眼与对侧未受累眼之间泪液流率的差异。
- 共纳入30例单侧PANDO患者(中位年龄45.5岁;25例女性),溢泪平均病程20个月。
主要发现
- PANDO眼与非PANDO眼NIBUT无显著差异(均值11.56 vs 11.58 s;p=0.49)。
- PANDO眼与非PANDO眼Schirmer I值无显著差异(均值18.83 vs 19.4 mm;p=0.313)。
- PANDO眼与非PANDO眼睑部泪腺大小相似(29.3 vs 28.6 mm2;p=0.41)。
- PANDO眼与非PANDO眼泪道开口数相似(中位数2 vs 2.5)。
- PANDO侧泪腺平均泪液流率较对侧未受累侧显著降低(0.8 vs 0.99 µL/min;p=0.014)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the effects of lacrimal drainage obstructions on the lacrimal gland activity and if there exists a potential link between the two. METHODS: Direct assessment of the lacrimal gland activity from the palpebral lobe was performed in consecutive patients diagnosed with unilateral primary acquired nasolacrimal duct obstruction (PANDO), along with Ocular Surface Disease Index (OSDI), non-invasive tear break up time (NIBUT; Oculus K5M), tear meniscus height and Schirmer I. The primary outcome measure was the difference in the tear flow rate between the eye with PANDO and the contralateral uninvolved eye. RESULTS: Thirty patients (median age, 45.5 years; 25 females) with unilateral PANDO had epiphora for a mean duration of 20 months. The mean OSDI score was 6.3. NIBUT (mean 11.56 vs 11.58 s; p=0.49) and Schirmer I values (mean 18.83 vs 19.4 mm; p=0.313) were not significantly different between PANDO and non-PANDO eyes. The morphology of the palpebral lobe (size 29.3 vs 28.6 mm2, p=0.41) and the number of lacrimal ductular openings (median 2 vs 2.5) were similar between the two eyes. The mean tear flow from the lacrimal glands of the PANDO side was significantly reduced compared with the contralateral uninvolved side (0.8 vs 0.99 µL/min; p=0.014)). CONCLUSION: Tear flow rate from palpebral lobes of patients with unilateral lacrimal outflow obstruction shows a significant reduction compared with the contralateral side. The potential ways of communications between the tear drainage and the tear production mechanisms need to be explored further.
引用
- Singh S, Srivastav S, Bothra N, et al. Lacrimal gland activity in lacrimal drainage obstruction: exploring the potential cross-talk between the tear secretion and outflow. Br J Ophthalmol. 2024. PMID: 37142331. doi:10.1136/bjo-2022-322577
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。