光学相干断层扫描结构参数用于高度近视青光眼诊断的比较
这项回顾性横断面研究纳入132例高度近视合并青光眼患者和142例高度近视无青光眼患者,比较各光学相干断层扫描(OCT)参数、UNC OCT指数及颞侧缝合征的诊断效能,发现颞下黄斑区神经节细胞-内丛状层(GCIPL)厚度的AUROC最高(0.951)。
要点
- 颞下GCIPL厚度的AUROC为0.951,高于UNC OCT指数、颞侧缝合征、平均RNFL厚度和视盘沿面积。
- 颞侧缝合征阳性的AUROC为0.922,UNC OCT指数的AUROC为0.891。
- 在高度近视中,RNFL厚度和GCIPL厚度参数对青光眼诊断的作用可能大于视盘参数。
核心结论
- 在高度近视患者中鉴别青光眼性眼时,颞下GCIPL厚度产生的AUROC值最高。
- 在高度近视中,RNFL厚度和GCIPL厚度参数对青光眼诊断的作用可能大于视盘参数。
研究设计与样本
- 回顾性横断面研究,2014年1月1日至2022年1月1日在韩国一家三级医院招募参与者。
- 纳入132例高度近视合并青光眼患者(平均[SD]年龄50.0[11.7]岁;男性78例[59.1%])和142例高度近视无青光眼患者(平均[SD]年龄50.0[11.3]岁;女性79例[55.6%])。
- 高度近视定义:眼轴长度≥26.0 mm或等效球镜≤-6屈光度。
- 测量黄斑区神经节细胞-内丛状层(GCIPL)厚度、视盘周围视网膜神经纤维层(RNFL)厚度和视神经乳头(ONH)参数,并检查UNC OCT评分和颞侧缝合征。
主要发现
- UNC OCT指数的AUROC为0.891(95%CI,0.848-0.925)。
- 颞侧缝合征阳性的AUROC为0.922(95%CI,0.883-0.950)。
- 最佳单一OCT参数为颞下GCIPL厚度(AUROC,0.951;95%CI,0.918-0.973)。
- 颞下GCIPL厚度与UNC OCT指数的AUROC差异为0.060(95%CI,0.016-0.103;P=0.007)。
- 颞下GCIPL厚度与颞侧缝合征的AUROC差异为0.029(95%CI,-0.009至0.068;P=0.13),与平均RNFL厚度的差异为0.022(95%CI,-0.012-0.055;P=0.21),与ONH沿面积的差异为0.075(95%CI,0.031-0.118;P<0.001)。
关键数值与推荐
- 颞下GCIPL厚度AUROC为0.951(95%CI,0.918-0.973),为最佳单一OCT参数。
- 颞侧缝合征阳性AUROC为0.922(95%CI,0.883-0.950)。
- UNC OCT指数AUROC为0.891(95%CI,0.848-0.925)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: Diagnosis of glaucoma in highly myopic eyes is challenging. This study compared the glaucoma detection utility of various optical coherence tomography (OCT) parameters for high myopia. OBJECTIVE: To compare the diagnostic accuracy of single OCT parameters, the University of North Carolina (UNC) OCT Index, and the temporal raphe sign for discrimination of glaucoma in patients with high myopia. DESIGN, SETTING, AND PARTICIPANTS: This was a retrospective cross-sectional study conducted from January 1, 2014, and January 1, 2022. Participants with high myopia (axial length ≥26.0 mm or spherical equivalent ≤-6 diopters) plus glaucoma and participants with high myopia without glaucoma were recruited from a single tertiary hospital in South Korea. EXPOSURES: Macular ganglion cell-inner plexiform layer (GCIPL) thickness, peripapillary retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured in each participant. The UNC OCT scores and the temporal raphe sign were checked to compare diagnostic utility. Decision tree analysis with single OCT parameters, the UNC OCT Index, and the temporal raphe sign were also applied. MAIN OUTCOME AND MEASURES: Area under the receiver operating characteristic curve (AUROC). RESULTS: A total of 132 individuals with high myopia and glaucoma (mean [SD] age, 50.0 [11.7] years; 78 male [59.1%]) along with 142 individuals with high myopia without glaucoma (mean [SD] age, 50.0 [11.3] years; 79 female [55.6%]) were included in the study. The AUROC of the UNC OCT Index was 0.891 (95% CI, 0.848-0.925). The AUROC of temporal raphe sign positivity was 0.922 (95% CI, 0.883-0.950). The best single OCT parameter was inferotemporal GCIPL thickness (AUROC, 0.951; 95% CI, 0.918-0.973), and its AUROC difference from the UNC OCT Index, temporal raphe sign, mean RNFL thickness, and ONH rim area was 0.060 (95% CI, 0.016-0.103; P = .007); 0.029 (95% CI, -0.009 to 0.068; P = .13), 0.022 (95% CI, -0.012-0.055; P = .21), and 0.075 (95% CI, 0.031-0.118; P < .001), respectively. CONCLUSIONS AND RELEVANCE: Results of this cross-sectional study suggest that in discriminating glaucomatous eyes in patients with high myopia, inferotemporal GCIPL thickness yielded the highest AUROC value. The RNFL thickness and GCIPL thickness parameters may play a greater role in glaucoma diagnosis than the ONH parameters in high myopia.
引用
- Jeong Y, Kim YK, Jeoung JW, et al. Comparison of Optical Coherence Tomography Structural Parameters for Diagnosis of Glaucoma in High Myopia. JAMA Ophthalmol. 2023. PMID: 37200038. doi:10.1001/jamaophthalmol.2023.1717
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。