文献速递青光眼角膜与眼表疾病

Baerveldt青光眼植入物经平坦部与经角膜缘插入后角膜内皮细胞丢失的不同模式

Different patterns in the corneal endothelial cell loss after pars plana and pars limbal insertion of the Baerveldt glaucoma implant.
PubMed 文献 · Am J Ophthalmol · 2023-04-28

该回顾性多中心介入比较研究评估了192眼Baerveldt青光眼植入物(BGI)术后5年中央角膜内皮细胞(CE)丢失。经角膜缘(PL)插入组大疱性角膜病变(BK)患病率高于经平坦部(PP)组(P = .003)。术前CE密度低(P < .001)和插入部位(P = .020)是BK发生的显著危险因素,PP管植入在术前CE密度低时可能有利。

要点

  • PL组大疱性角膜病变患病率高于PP组(P = .003)。
  • PP组CE年丢失呈单向下降,PL组呈双相模式。
  • 术前CE密度低和插入部位是BK发生的显著危险因素。

核心结论

  • PL组和PP组的CE丢失分别呈双相和单向模式,年CE丢失差异随时间变得明显。
  • 当术前CE密度低时,PP管植入可能有利。

研究设计与样本

  • 回顾性多中心介入比较研究,研究192眼BGI术后5年中央CE丢失。

主要发现

  • PL队列BK患病率高于PP队列(P = .003)。
  • 同时行PP玻璃体切除和管插入玻璃体腔者第一年CE丢失为11.9%,高于既往玻璃体切除后单纯管插入玻璃体腔者的2.9%(P = .046)。
  • 上述两组第一年后年CE丢失百分比单向下降,第五年分别为1.3%和1.0%(P < .001)。
  • 单纯PL队列CE丢失呈双相,从第一年10.5%降至第五年7.0%。
  • 同时行白内障和BGI手术使PP和PL队列第一年CE丢失分别略增至13.0%和14.0%,但增加不显著(P = .816和.358)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess corneal endothelial cell (CE) loss after pars plana (PP) and pars limbal (PL) insertion of a Baerveldt glaucoma implant (BGI). DESIGN: Retrospective multicenter interventional comparative study. METHODS: We studied central CE loss for 5 years after BGI surgery in 192 eyes. RESULTS: The prevalence of bullous keratopathy (BK) was greater in the PL cohort than in the PP cohort (P = .003). The CE loss after simultaneous PP vitrectomy and tube insertion into the vitreous cavity was 11.9% in the first year, which was greater than that of 2.9% in eyes where the tube was inserted simply into the vitreous cavity after a prior vitrectomy (P = .046). The annual percentage CE loss after the first year decreased unidirectionally in both of those groups and was 1.3% and 1.0% in the fifth year, respectively (P < .001). For limbal insertion, the CE loss in the simple PL cohort was biphasic, decreasing from 10.5% in the first year to 7.0% in the fifth year. Simultaneous cataract and BGI surgery enhanced the CE loss slightly in the first year in the PP and PL cohorts to 13.0% and 14.0%, respectively. However, these increases were not significant (P = .816 and .358, respectively). Low preoperative CE density (P < .001) and insertion site (P = .020) were significant risk factors for the development of BK. CONCLUSIONS: CE loss in the PL and PP cohorts was biphasic and unidirectional, respectively. The difference in annual CE loss became evident over time. PP tube implantation may be advantageous when the preoperative CE density is low.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Chihara E, Tanito M, Kono M, et al. Different patterns in the corneal endothelial cell loss after pars plana and pars limbal insertion of the Baerveldt glaucoma implant. Am J Ophthalmol. 2023. PMID: 37119996. doi:10.1016/j.ajo.2023.03.038