文献速递角膜与眼表疾病

通过融合训练模型利用智能手机准确检测和分级翼状胬肉

Accurate detection and grading of pterygium through smartphone by a fusion training model.
PubMed 文献 · Br J Ophthalmol · 2024-02-21

本研究将20987张裂隙灯图像与1094张智能手机图像融合训练模型,用于翼状胬肉检测与分级。融合分割模型在智能手机图像上F1为0.9313、敏感度0.9360、特异度0.9613、AUC为0.9426、准确率92.38%,接近裂隙灯图像模型在裂隙灯图像上的表现(F1 0.9448、敏感度0.9165、特异度0.9689、AUC 0.9569、准确率94.29%)。

要点

  • 检测模型(裂隙灯图像训练)平均准确率为95.24%。
  • 融合分割模型微平均F1为0.8981、敏感度0.8709、特异度0.9668、AUC为0.9295。
  • 融合模型在智能手机图像上的表现与裂隙灯图像模型在裂隙灯图像上的表现接近。

核心结论

  • 融合模型方法在智能手机数据不足时获得了较高的翼状胬肉检测和分级准确率,其性能与有经验的眼科医生相当,并在不同智能手机品牌上表现良好。

研究设计与样本

  • 使用两个数据集:包含20987张图像的裂隙灯图像数据集和包含1094张图像的智能手机图像数据集。
  • 检测模型为RFRC(基于ResNet101的Faster RCNN),分割模型为SRU-Net(基于SE-ResNeXt50的U-Net),并用open-cv算法测量角膜内翼状胬肉的宽度、长度和面积。

主要发现

  • 检测模型(裂隙灯图像训练)获得平均准确率95.24%。
  • 融合分割模型(智能手机和裂隙灯图像训练)达到微平均F1分数0.8981、敏感度0.8709、特异度0.9668、AUC 0.9295。
  • 同一组患者的智能手机与裂隙灯图像对比:融合模型在智能手机图像上F1分数0.9313、敏感度0.9360、特异度0.9613、AUC 0.9426、准确率92.38%。
  • 裂隙灯图像训练的模型在裂隙灯图像上F1分数0.9448、敏感度0.9165、特异度0.9689、AUC 0.9569、准确率94.29%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To improve the accuracy of pterygium screening and detection through smartphones, we established a fusion training model by blending a large number of slit-lamp image data with a small proportion of smartphone data. METHOD: Two datasets were used, a slit-lamp image dataset containing 20 987 images and a smartphone-based image dataset containing 1094 images. The RFRC (Faster RCNN based on ResNet101) model for the detection model. The SRU-Net (U-Net based on SE-ResNeXt50) for the segmentation models. The open-cv algorithm measured the width, length and area of pterygium in the cornea. RESULTS: The detection model (trained by slit-lamp images) obtained the mean accuracy of 95.24%. The fusion segmentation model (trained by smartphone and slit-lamp images) achieved a microaverage F1 score of 0.8981, sensitivity of 0.8709, specificity of 0.9668 and area under the curve (AUC) of 0.9295. Compared with the same group of patients' smartphone and slit-lamp images, the fusion model performance in smartphone-based images (F1 score of 0.9313, sensitivity of 0.9360, specificity of 0.9613, AUC of 0.9426, accuracy of 92.38%) is close to the model (trained by slit-lamp images) in slit-lamp images (F1 score of 0.9448, sensitivity of 0.9165, specificity of 0.9689, AUC of 0.9569 and accuracy of 94.29%). CONCLUSION: Our fusion model method got high pterygium detection and grading accuracy in insufficient smartphone data, and its performance is comparable to experienced ophthalmologists and works well in different smartphone brands.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Liu Y, Xu C, Wang S, et al. Accurate detection and grading of pterygium through smartphone by a fusion training model. Br J Ophthalmol. 2024. PMID: 36858799. doi:10.1136/bjo-2022-322552

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。