文献速递青光眼

使用接触镜传感器24小时监测眼压波动:对青光眼进展的诊断性能

24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2023-01-01

在波尔多大学医院开展的横断面研究纳入54只开角型青光眼眼,用接触镜传感器行24小时眼压相关波动监测,按视野平均偏差进展速率分为快速进展组(<-0.5 dB/年)与较慢进展组(≥-0.5 dB/年),发现快速进展组24小时波动幅度及曲线下面积显著更高,提示该波动特征可能作为进展风险因素。

要点

  • 快速进展组(n=22)平均进展速率为-1.09±0.60 dB/年,较慢进展组(n=32)为-0.12±0.13 dB/年。
  • 快速进展组24小时波动幅度343.1±62.3毫伏、曲线下面积8.28±2.10毫伏,均显著高于较慢进展组的274.0±75.0毫伏和6.82±2.70毫伏(P<0.05)。
  • 60至220分钟短频率周期的波幅与波let曲线下面积在快速进展组也显著更高(P<0.05)。

核心结论

  • 接触镜传感器评估的24小时眼压相关波动特征可能作为开角型青光眼进展的风险因素。
  • 结合其他青光眼进展预测因素,接触镜传感器可能有助于更早调整治疗策略。

研究设计与样本

  • 波尔多大学医院开展的横断面研究,共纳入54例患者的54只眼。
  • 使用接触镜传感器(Triggerfish;SENSIMED,Etagnières,瑞士)进行24小时监测。
  • 以Octopus视野计平均偏差参数的线性回归计算进展速率,按<-0.5 dB/年与≥-0.5 dB/年分为两组。
  • 开发自动信号处理程序,采用小波变换分析对监测信号进行频率滤波,比较两组输出信号,并用多变量分类器预测快速进展组。

主要发现

  • 快速进展组(n=22)平均进展速率为-1.09±0.60 dB/年,较慢进展组(n=32)为-0.12±0.13 dB/年。
  • 快速进展组24小时波动幅度为343.1±62.3毫伏,较慢进展组为274.0±75.0毫伏,快速进展组显著更高(P<0.05)。
  • 快速进展组24小时曲线下面积为8.28±2.10毫伏,较慢进展组为6.82±2.70毫伏,快速进展组显著更高(P<0.05)。
  • 60至220分钟短频率周期的波幅与波let曲线下面积在快速进展组也显著更高(P<0.05)。

关键数值与推荐

  • 分组标准:视野平均偏差进展速率<-0.5 dB/年归入快速进展组,≥-0.5 dB/年归入较慢进展组。
  • 快速进展组24小时波动幅度343.1±62.3毫伏 vs 较慢进展组274.0±75.0毫伏(P<0.05)。
  • 快速进展组24小时曲线下面积8.28±2.10毫伏 vs 较慢进展组6.82±2.70毫伏(P<0.05)。
  • 60至220分钟短频率周期的波幅与波let曲线下面积在快速进展组显著更高(P<0.05)。

临床怎么用

  • 作者认为接触镜传感器评估的24小时眼压相关波动特征可能作为开角型青光眼进展的风险因素。
  • 作者认为结合其他青光眼进展预测因素,接触镜传感器可能有助于更早调整治疗策略。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to compare 24-hour intraocular pressure (IOP) related fluctuations monitoring between 2 groups of visual field progression rates in patients with open angle glaucoma (OAG). METHODS: Cross-sectional study performed at Bordeaux University Hospital. Twenty-four-hour monitoring was performed using a contact lens sensor (CLS; Triggerfish; SENSIMED, Etagnières, Switzerland). Progression rate was calculated using a linear regression of the mean deviation (MD) parameter of the visual field test (Octopus; HAAG-STREIT, Switzerland). Patients were allocated into two groups: group 1 with an MD progression rate <-0.5 dB/year and group 2 with an MD progression rate ≥-0.5 dB/year. An automatic signal-processing program was developed and a frequency filtering of the monitoring by wavelet transform analysis was used to compare the output signal between the two groups. A multivariate classifier was performed for prediction of the faster progression group. RESULTS: Fifty-four eyes of 54 patients were included. The mean progression rate was -1.09 ± 0.60 dB/year in group 1 (n = 22) and -0.12 ± 0.13 dB/year in group 2 (n = 32). Twenty-four-hour magnitude and absolute area under the monitoring curve were significantly higher in group 1 than in group 2 (group 1: 343.1 ± 62.3 millivolts [mVs] and 8.28 ± 2.10 mVs, respectively, group 2: 274.0 ± 75.0 mV and 6.82 ± 2.70 mVs respectively, P < 0.05). Magnitude and area under the wavelet curve for short frequency periods ranging from 60 to 220 minutes were also significantly higher in group 1 (P < 0.05). CONCLUSIONS: The 24-hour IOP related fluctuations characteristics, as assessed by a CLS, may act as a risk factor for progression in OAG. In association with other predictive factors of glaucoma progression, the CLS may help adjust treatment strategy earlier.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Gaboriau T, Dubois R, Foucque B, et al. 24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression. Invest Ophthalmol Vis Sci. 2023. PMID: 36862120. doi:10.1167/iovs.64.3.3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。