文献速递眼底病与葡萄膜炎青光眼神经眼科

人工智能系统在中国基层医疗场景筛查多种眼底疾病的应用:一项涵盖4795例的真实世界多中心横断面研究

Application of artificial intelligence system for screening multiple fundus diseases in Chinese primary healthcare settings: a real-world, multicentre and cross-sectional study of 4795 cases.
PubMed 文献 · Br J Ophthalmol · 2024-02-21

该真实世界多中心横断面研究纳入上海和新疆6家基层医疗机构的4795名参与者,评估Airdoc视网膜人工智能系统(ARAS)筛查正常眼底和14种视网膜异常的表现。ARAS对正常眼底和14种视网膜异常的准确度、特异度和阴性预测值较高,但不同异常的敏感度和阳性预测值存在差异,且两地眼底疾病谱存在显著差异。

要点

  • ARAS筛查正常眼底和14种视网膜异常的准确度、特异度和阴性预测值较高,但敏感度和阳性预测值因异常类型而异。
  • 上海视网膜玻璃膜疣、病理性近视和青光眼性视神经病变比例显著高于新疆。
  • 新疆中老年人需转诊的糖尿病视网膜病变、视网膜静脉阻塞和黄斑水肿百分比显著高于上海。

核心结论

  • 本研究证明ARAS在基层医疗场景检测多种视网膜疾病具有可靠性。
  • 在基层医疗场景实施人工智能辅助眼底疾病筛查系统可能有助于缩小医疗资源的地区差异。
  • ARAS算法必须改进以达到更好的表现。

研究设计与样本

  • 本研究为真实世界、多中心、横断面研究,在中国上海和新疆开展,纳入6家基层医疗机构。
  • 共纳入4795名参与者,中位年龄57.0岁(IQR 39.0-66.0),女性3175名(66.2%)。
  • 拍摄彩色眼底照片,由ARAS和视网膜专家进行分级。
  • 通过准确度、敏感度、特异度、阳性预测值和阴性预测值描述ARAS的表现,并调查基层医疗场景的眼底疾病谱。

主要发现

  • ARAS检测正常眼底和14种视网膜异常的准确度、特异度和阴性预测值较高,而检测不同异常的敏感度和阳性预测值存在差异。
  • 上海视网膜玻璃膜疣、病理性近视和青光眼性视神经病变的比例显著高于新疆。
  • 新疆中老年人需转诊的糖尿病视网膜病变、视网膜静脉阻塞和黄斑水肿的百分比显著高于上海。

临床怎么用

  • 原文结论认为,在基层医疗场景实施人工智能辅助眼底疾病筛查系统可能有助于缩小医疗资源的地区差异。
  • 原文结论认为,ARAS算法必须改进以达到更好的表现。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: This study evaluates the performance of the Airdoc retinal artificial intelligence system (ARAS) for detecting multiple fundus diseases in real-world scenarios in primary healthcare settings and investigates the fundus disease spectrum based on ARAS. METHODS: This real-world, multicentre, cross-sectional study was conducted in Shanghai and Xinjiang, China. Six primary healthcare settings were included in this study. Colour fundus photographs were taken and graded by ARAS and retinal specialists. The performance of ARAS is described by its accuracy, sensitivity, specificity and positive and negative predictive values. The spectrum of fundus diseases in primary healthcare settings has also been investigated. RESULTS: A total of 4795 participants were included. The median age was 57.0 (IQR 39.0-66.0) years, and 3175 (66.2%) participants were female. The accuracy, specificity and negative predictive value of ARAS for detecting normal fundus and 14 retinal abnormalities were high, whereas the sensitivity and positive predictive value varied in detecting different abnormalities. The proportion of retinal drusen, pathological myopia and glaucomatous optic neuropathy was significantly higher in Shanghai than in Xinjiang. Moreover, the percentages of referable diabetic retinopathy, retinal vein occlusion and macular oedema in middle-aged and elderly people in Xinjiang were significantly higher than in Shanghai. CONCLUSION: This study demonstrated the dependability of ARAS for detecting multiple retinal diseases in primary healthcare settings. Implementing the AI-assisted fundus disease screening system in primary healthcare settings might be beneficial in reducing regional disparities in medical resources. However, the ARAS algorithm must be improved to achieve better performance. TRIAL REGISTRATION NUMBER: NCT04592068.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Gu C, Wang Y, Jiang Y, et al. Application of artificial intelligence system for screening multiple fundus diseases in Chinese primary healthcare settings: a real-world, multicentre and cross-sectional study of 4795 cases. Br J Ophthalmol. 2024. PMID: 36878715. doi:10.1136/bjo-2022-322940

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。