文献速递眼外伤

开放性眼球损伤手术修复中区域麻醉与全身麻醉使用方式的演变

Evolving Use of Regional versus General Anesthesia for the Surgical Repair of Open Globe Injuries.
PubMed 文献 · Am J Ophthalmol · 2023-02-22

该回顾性对照研究纳入2015至2020年507例开放性眼球损伤患者,其中91%在区域麻醉联合监护麻醉下完成修复,9%在全身麻醉下完成。两种麻醉方式术后视力改善相似(区域麻醉组0.52 logMAR vs 全身麻醉组0.46 logMAR,P=.68,CI -0.3至0.2)。本机构区域麻醉使用比例从1995-1999年的64%上升至2015-2020年的91%(P<.00001)。

要点

  • 507例开放性眼球损伤中91%在区域麻醉联合监护麻醉下修复,9%在全身麻醉下修复。
  • 区域麻醉组与全身麻醉组术后视力改善相似(0.52 vs 0.46 logMAR,P=.68)。
  • 本机构区域麻醉使用比例由1995-1999年的64%升至2015-2020年的91%。

核心结论

  • 在有眼科区域麻醉经验的麻醉医师参与并适当选择病例的前提下,区域麻醉联合监护麻醉可作为全身麻醉的替代方式安全用于开放性眼球损伤修复。

研究设计与样本

  • 回顾性、连续入组、对比性、非随机临床研究,纳入2015至2020年某三级转诊中心507例(507眼)开放性眼球损伤患者,未预设麻醉方式选择方案。

主要发现

  • 开放性眼球损伤一期缝合在区域麻醉联合监护麻醉下完成462例(91%),在全身麻醉下完成45例(9%)。
  • 1区、2区、3区损伤分别为251例、170例、86例;1区(96%,251例中240例)或2区(92%,170例中156例)较3区(76%,86例中65例)更可能在区域麻醉联合监护麻醉下修复(P<.001)。
  • 区域麻醉联合监护麻醉组与全身麻醉组相对就诊视力的改善相似,分别为0.52 logMAR和0.46 logMAR(P=.68,CI -0.3至0.2)。
  • 本机构开放性眼球损伤使用区域麻醉联合监护麻醉的比例从1995-1999年的64%上升至本研究2015-2020年的91%(P<.00001)。

临床怎么用

  • 作者认为,在有眼科区域麻醉经验的麻醉医师参与并适当选择病例的前提下,区域麻醉联合监护麻醉可作为全身麻醉的替代方式安全用于开放性眼球损伤修复。
  • 采用区域麻醉联合监护麻醉时需考虑患者在整个眼球修复期间的合作、体位配合和沟通能力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of the current study is to report outcomes with the evolving use of regional anesthesia with monitored anesthesia care (RA-MAC) vs general anesthesia (GA) in the repair of open globe injuries. DESIGN: Retrospective, consecutive, comparative, nonrandomized clinical study. METHODS: The study includes 507 eyes of 507 patients with open globe injuries treated with either RA-MAC or GA at a tertiary referral center between 2015 and 2020. There was no predetermined protocol for selection of anesthesia method. However, based on experience and findings of prior research by this group, regional anesthesia with monitored anesthesia care was typically selected initially and changed to general anesthesia if warranted after evaluation of the patient and discussion with the surgeon. The main outcome measure was visual acuity at last follow-up. Results were compared to previously published study groups between 1995 and 2014. RESULTS: Primary closure of open globe injury was performed under RA-MAC anesthesia in 462 patients (91%) and under GA in 45 patients (9%). Zone 1, 2, and 3 injuries were recorded in 251, 170, and 86 patients, respectively. Zone 1 (96%, 240 of 251 patients) or zone 2 (92%, 156 of 170 patients) (P < .001) were more likely to be repaired under RA-MAC vs zone 3 injuries (76%, 65 of 86 patients). The improvement from presenting visual acuity was similar for the 2 anesthesia groups, 0.52 logMAR and 0.46 logMAR for RA-MAC and GA, respectively (P = .68, CI -0.3 to 0.2). The use of RA-MAC anesthesia for open globe injuries has increased at our institution from 64% in 1995-1999 to 91% in the present study, 2015-2020 (P < .00001). CONCLUSION: The current study demonstrates that with anesthesiologists experienced in ophthalmic regional anesthesia techniques, and appropriate case selection, RA-MAC can be safely used as an alternative to general anesthesia for open globe repair. Considerations when employing RA-MAC include a patient's ability to cooperate, position, and communicate for the duration of the globe repair.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Fan J, Hudson JL, Fan KC, et al. Evolving Use of Regional versus General Anesthesia for the Surgical Repair of Open Globe Injuries. Am J Ophthalmol. 2023. PMID: 36822572. doi:10.1016/j.ajo.2023.02.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。