文献速递眼底病与葡萄膜炎

利用余弦定律为高度近视眼黄斑手术选择正确的镊子杆长度

The Cosine Law to Choose the Correct Forceps Shaft Length for Macular Surgery in Highly Myopic Eyes.
PubMed 文献 · Retina · 2023-01-01

该文用勾股定理建立数学模型,将角膜中央至巩膜切口的距离与镊子杆长度进行类比,推导余弦定律以估算巩膜切口至黄斑区的距离。结果显示该距离短于眼轴长度,并随巩膜切口至角膜缘的距离变化而变小。作者认为该公式在高度近视眼黄斑手术中有助于选择合适镊子杆长度。

要点

  • 以勾股定理类比:眼轴为斜边,角膜光线与角膜缘至巩膜切口距离之和为底边,巩膜切口至黄斑距离为垂直边。
  • 推导出余弦定律用于估算巩膜切口至黄斑区的距离。
  • 巩膜切口至黄斑区距离短于眼轴长度,且随巩膜切口至角膜缘距离变化而变小。

核心结论

  • 该简单数学公式在高度近视眼手术中有助于选择合适镊子杆长度,此类眼可能存在到达黄斑区的困难。

研究设计与样本

  • 该文为数学类比分析,利用A超测量的眼轴长度(角膜中央至巩膜切口距离)与镊子长度建立勾股定理模型。

主要发现

  • 以勾股方程c²=a²+b²计算黄斑手术所需镊子杆长度,其中c²代表眼轴长度(斜边),b²为角膜光线与角膜缘至巩膜切口距离之和(底边),a²为巩膜切口至黄斑距离(垂直边)。
  • 复现余弦定律以估算巩膜切口至黄斑区的距离。
  • 巩膜切口至黄斑区的距离短于眼轴长度,并可根据巩膜切口至角膜缘的距离变小。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To demonstrate a mathematical analogy between the Pythagorean theorem using the axial a-scan measurement, i.e., the distance between the central cornea and the sclerotomy, and the lengths of the forceps in eyes of patients with all axial lengths. METHODS: We used the Pythagorean equation (c 2 = a 2 + b 2 ) to calculate the adequate shaft length of the forceps to use in macular surgery, especially in highly myopic eyes, where c 2 represents the axial length (hypotenuse); b 2 the sum of the corneal ray and distance between the corneal limbus and the sclerotomy (base side); and a 2 the distance between the sclerotomy and the fovea (perpendicular side). RESULTS: We reproduced the cosine law to estimate the distance between the sclerotomy and the fovea. The distance between the sclerotomy and the foveal area is shorter than the axial length and can become smaller based on the distance from the sclerotomy to the corneal limbus. CONCLUSION: This simple mathematical formula is useful when performing surgery in highly myopic eyes, in which there can be difficulties reaching the macular area.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Teixeira A, Salaroli C, Fuganti RM, et al. The Cosine Law to Choose the Correct Forceps Shaft Length for Macular Surgery in Highly Myopic Eyes. Retina. 2023. PMID: 36729566. doi:10.1097/IAE.0000000000003704

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。