飞秒激光辅助开放性散光角膜切开术与非开放性散光角膜切开术矫正白内障手术角膜散光的对比
前瞻性队列研究纳入2021年6月至2022年6月在解放军陆军特色医学中心行白内障摘除手术的连续病例51例61只眼,按患者意愿分为开放性FSAK组27例31只眼与非开放性FSAK组24例30只眼。术后3个月Pentacam HR检查显示两组目标散光矫正量差异无统计学意义,开放性FSAK组术源性散光更高、残余散光更小、矫正指数更高,角度误差差异无统计学意义。结论认为开放性FSAK可取得更好的散光矫正效果和更小的术后残余散光。
要点
- 开放性FSAK组残余散光(0.51±0.31)D低于非开放性FSAK组(1.21±0.44)D,P<0.001。
- 开放性FSAK组术源性散光0.70(0.59,1.25)D高于非开放性FSAK组0.42(0.20,0.66)D,P<0.001。
- 两组目标散光矫正量与角度误差差异均无统计学意义。
核心结论
- 开放性FSAK对比非开放性FSAK可以取得更好的散光矫正效果和更小的术后残余散光。
研究设计与样本
- 前瞻性队列研究,纳入2021年6月至2022年6月到解放军陆军特色医学中心眼科行白内障摘除手术的连续病例,根据患者意愿选择手术方式。
- 观察组为开放性FSAK,对照组为非开放性FSAK,两组均在LensAR飞秒激光手术平台下行飞秒激光辅助白内障超声乳化联合人工晶状体植入术。
- 观察组对FSAK切口的角膜上皮进行手动开放,对照组不作手动开放;术后3个月行Pentacam HR角膜地形图检查。
- 纳入患者51例(61只眼),其中观察组27例(31只眼),对照组24例(30只眼)。
主要发现
- 两组患者年龄、性别及平均随访时间差异均无统计学意义(P>0.05)。
- 观察组与对照组的目标散光矫正量分别为1.10(0.80,1.50)D和1.30(0.98,1.73)D,差异无统计学意义(Z=1.729,P=0.084)。
- 观察组与对照组的术源性散光分别为0.70(0.59,1.25)D和0.42(0.20,0.66)D,差异有统计学意义(Z=-3.571,P<0.001)。
- 观察组与对照组的残余散光分别为(0.51±0.31)D和(1.21±0.44)D,差异有统计学意义(t=-7.238,P<0.001)。
- 观察组与对照组的矫正指数分别为0.78±0.32和0.38±0.25,差异有统计学意义(t=5.386,P<0.001);角度误差分别为-1.08°±10.76°和5.93°±46.98°,差异无统计学意义(t=0.809,P=0.422)。
临床怎么用
- 原文结论认为开放性FSAK对比非开放性FSAK可以取得更好的散光矫正效果和更小的术后残余散光。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To compare the effects of femtosecond laser-assisted astigmatic keratotomy (FSAK) with and without a manual opening for correction of low to moderate corneal astigmatism at the time of cataract surgery. Methods: It was a prospective cohort study. Patients undergoing cataract surgery from June 2021 to June 2022 at the Army Specialty Medical Center were consecutively enrolled. To correct low to moderate astigmatism, they had combined FSAK with the corneal epithelium manually opened or not according to their own decisions. Pentacam HR corneal topography was performed at 3 months after surgery. The main indicators were target induced astigmatism, surgically induced astigmatism, difference vector, correction index and angle of error. The independent samples t-test was used for continuous variables conforming to a normal distribution, the Mann-Whitney U-test for those not conforming to a normal distribution, and the Chi-square test for categorical variables. Results: There were 51 patients (61 eyes), including 27 patients (31 eyes) receiving combined open FSAK and 24 patients (30 eyes) with non-open keratotomy. No statistical difference was found between the two groups of patients in terms of age, gender and mean follow-up time (P>0.05). The target induced astigmatism was 1.10(0.80, 1.50) D in patients with open keratotomy and 1.30(0.98, 1.73) D in patients with non-open keratotomy (Z=1.729, P=0.084). The surgically induced astigmatism was 0.70 (0.59, 1.25) D and 0.42 (0.20, 0.66) D (Z=-3.571, P<0.001), the difference vector was (0.51±0.31) D and (1.21±0.44) D (t=-7.238, P<0.001), the correction index was 0.78±0.32 and 0.38±0.25 (t=5.386, P<0.001), and the angle of error was -1.08°±10.76° and 5.93°±46.98° (t=0.809, P=0.422) in the two groups, respectively. Conclusion: Open FSAK can achieve better astigmatism correction and less postoperative residual astigmatism than non-open FSAK in cataract surgery. 目的: 对比飞秒激光辅助的白内障摘除手术联合角膜散光松解术(FSAK)中对FSAK切口表面进行手动开放与不开放对于中低度角膜散光的矫正效果。 方法: 前瞻性队列研究。纳入2021年6月至2022年6月到解放军陆军特色医学中心眼科行白内障摘除手术的连续病例,根据患者意愿选择决定手术方式,观察组为开放性FSAK,对照组为非开放性FSAK。两组患者均在LensAR飞秒激光手术平台下行飞秒激光辅助白内障超声乳化联合人工晶状体植入术,术中观察组对FSAK切口的角膜上皮进行手动开放,对照组不作手动开放。术后3个月行Pentacam HR角膜地形图检查。检查所有术眼的目标散光矫正量、术源性散光、残余散光、矫正指数、角度误差。符合正态分布的连续变量进行独立样本t检验;不符合正态分布的连续变量进行Mann-Whitney U检验;分类变量使用卡方检验。 结果: 纳入患者51例(61只眼),其中观察组27例(31只眼),对照组24例(30只眼)。两组患者年龄、性别及平均随访时间差异均无统计学意义(P>0.05)。观察组与对照组的目标散光矫正量分别为1.10(0.80,1.50)和1.30(0.98,1.73)D,差异无统计学意义(Z=1.729,P=0.084);观察组与对照组的术源性散光分别为0.70(0.59,1.25)和0.42(0.20,0.66)D(Z=-3.571,P<0.001),残余散光分别为(0.51±0.31)和(1.21±0.44)D(t=-7.238,P<0.001),矫正指数分别为0.78±0.32和0.38±0.25(t=5.386,P<0.001),差异均有统计学意义;观察组与对照组的角度误差分别为-1.08°±10.76°和5.93°±46.98°,差异无统计学意义(t=0.809,P=0.422)。 结论: 开放性FSAK对比非开放性FSAK可以取得更好的散光矫正效果和更小的术后残余散光。.
引用
- Wu S, Yu T, Feng XL, et al. [Femtosecond laser-assisted open astigmatic keratotomy versus non-open astigmatic keratotomy for astigmatism correction in cataract surgery]. Zhonghua Yan Ke Za Zhi. 2023. PMID: 36740438. doi:10.3760/cma.j.cn112142-20220815-00402
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。