文献速递青光眼

比较视盘周围OCT扫描与视野检测青光眼恶化的准确性

Comparing the Accuracy of Peripapillary OCT Scans and Visual Fields to Detect Glaucoma Worsening.
PubMed 文献 · Ophthalmology · 2023-02-06

该描述性与模拟研究基于Wilmer眼科研究所2013至2021年12150只青光眼或疑似青光眼眼的OCT数据和20583只眼的视野数据,评估2年内不同检测次数下检测中度与快速恶化的准确性。结果显示OCT与视野检测2年恶化的准确性均低于50%,OCT准确性高于视野,联合两种检测准确性提高超过17个百分点。结论认为需要更频繁的OCT和视野检测,联合检测可大幅提高准确性。

要点

  • 2年内OCT和视野检测青光眼恶化的准确性均低于50%。
  • OCT检测中度恶化准确性比视野高5至10个百分点,快速恶化高10至15个百分点。
  • 联合OCT和视野检测时准确性提高超过17个百分点。

核心结论

  • 需要更频繁的OCT扫描和视野检测以提高诊断青光眼恶化的准确性。
  • 依赖OCT和视野两者联合检测恶化时准确性大幅增加。

研究设计与样本

  • 描述性与模拟研究,OCT样本包括Wilmer眼科研究所2013至2021年随访的7392名青光眼或疑似青光眼成人的12150只眼。

主要发现

  • 2年期内诊断恶化时,OCT和视野的准确性均低于50%。
  • 检测中度恶化时,OCT准确性比视野高5至10个百分点。
  • 检测快速恶化时,OCT准确性比视野高10至15个百分点。
  • 联合使用OCT和视野(依赖任一检测准确)检测恶化时,准确性提高超过17个百分点。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the accuracy of detecting moderate and rapid rates of glaucoma worsening over a 2-year period with different numbers of OCT scans and visual field (VF) tests in a large sample of glaucoma and glaucoma suspect eyes. DESIGN: Descriptive and simulation study. PARTICIPANTS: The OCT sample comprised 12 150 eyes from 7392 adults with glaucoma or glaucoma suspect status followed up at the Wilmer Eye Institute from 2013 through 2021. The VF sample comprised 20 583 eyes from 10 958 adults from the same database. All eyes had undergone at least 5 measurements over follow-up from the Zeiss Cirrus OCT or Humphrey Field Analyzer. METHODS: Within-eye rates of change in retinal nerve fiber layer (RNFL) thickness and mean deviation (MD) were measured using linear regression. For each measured rate, simulated measurements of RNFL thickness and MD were generated using the distributions of residuals. Simulated rates of change for different numbers of OCT scans and VF tests over a 2-year period were used to estimate the accuracy of detecting moderate (75th percentile) and rapid (90th percentile) worsening for OCT and VF. Accuracy was defined as the percentage of simulated eyes in which the true rate of worsening (the rate without measurement error) was at or less than a criterion rate (e.g., 75th or 90th percentile). MAIN OUTCOME MEASURES: The accuracy of diagnosing moderate and rapid rates of glaucoma worsening for different numbers of OCT scans and VF tests over a 2-year period. RESULTS: Accuracy was less than 50% for both OCT and VF when diagnosing worsening after a 2-year period. OCT accuracy was 5 to 10 percentage points higher than VF accuracy at detecting moderate worsening and 10 to 15 percentage points higher for rapid worsening. Accuracy increased by more than 17 percentage points when using both OCT and VF to detect worsening, that is, when relying on either OCT or VF to be accurate. CONCLUSIONS: More frequent OCT scans and VF tests are needed to improve the accuracy of diagnosing glaucoma worsening. Accuracy greatly increases when relying on both OCT and VF to detect worsening. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Bradley C, Herbert P, Hou K, et al. Comparing the Accuracy of Peripapillary OCT Scans and Visual Fields to Detect Glaucoma Worsening. Ophthalmology. 2023. PMID: 36754173. doi:10.1016/j.ophtha.2023.01.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。