使用视网膜神经纤维层厚度和布鲁赫膜开口最小边缘宽度检测青光眼的种族差异
该研究比较了基于参考数据库的视网膜神经纤维层厚度(RNFLT)和布鲁赫膜开口最小边缘宽度(BMO-MRW)标准在欧裔和非洲裔个体中检测青光眼的敏感性和特异性。结果显示,非洲裔个体的诊断性能持续低于欧裔个体,BMO-MRW标准在非洲裔个体中可能漏诊多达三分之一的青光眼眼。
要点
- 在非洲裔个体中,RNFLT和BMO-MRW标准检测青光眼的敏感性和特异性均低于欧裔个体。
- BMO-MRW标准在非洲裔个体中可能漏诊多达三分之一的青光眼眼。
- 基于当前参考数据库的RNFLT和BMO-MRW标准不足以在非洲裔个体中诊断青光眼。
核心结论
- RNFLT和BMO-MRW在非洲裔个体中的诊断性能持续低于欧裔个体。
研究设计与样本
- 比较性诊断分析,按种族分组;纳入255例青光眼患者(欧裔170例,非洲裔85例)的382只眼和50例健康个体(欧裔30例,非洲裔20例)的94只眼,使用Spectralis光学相干断层扫描(OCT)测量整体和分区RNFLT及BMO-MRW;评估六种诊断标准:整体测量低于第5或第1百分位、6个分区测量中至少1个低于第5或第1百分位、颞上(ST)和/或颞下(IT)测量低于第5或第1百分位;使用自举法比较敏感性和特异性。
主要发现
- 在RNFLT分类中,ST和/或IT RNFLT低于第5百分位检测青光眼表现最佳,敏感性(95% CI)为89.5%(86.1, 92.5),特异性为87.2%(77.8, 95.1)。
- 在非洲裔个体中,ST和IT RNFLT低于第5百分位标准的敏感性低于欧裔个体(RNFLT:83.7% vs 92.5%),BMO-MRW低于第5百分位标准的敏感性也低于欧裔个体(72.1% vs 88.5%)。
- 在非洲裔个体中,ST和IT RNFLT低于第5百分位标准的特异性低于欧裔个体(73.7% vs 96.4%),BMO-MRW低于第5百分位标准的特异性也低于欧裔个体(89.5% vs 98.2%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the sensitivities and specificities of the retinal nerve fiber layer thickness (RNFLT) and Bruch membrane opening minimum rim width (BMO-MRW) reference database-based criteria for detection of glaucoma in individuals of European descent (ED) and individuals of African descent (AD). DESIGN: Comparative diagnostic analysis by race METHODS: 382 eyes of 255 glaucoma patients (ED = 170, AD = 85) and 94 eyes of 50 healthy individuals (ED = 30, AD = 20) with global and sectoral RNFLT and BMO-MRW measured with Spectralis optical coherence tomography (OCT) were included. Six diagnostic criteria were evaluated: global measurement below the 5th or 1st percentile, ≥1 of the 6 sector measurements below the 5th or 1st percentile, and superotemporal (ST) and/or inferotemporal (IT) measurement below the 5th or 1st percentile. The sensitivities and specificities of these measurements for detection of glaucoma were compared using bootstrapping methods. RESULTS: ST and/or IT RNFLT below the 5th percentile has the best performance for detection of glaucoma among RNFLT classifications with a sensitivity (95% CI) of 89.5% (86.1, 92.5) and specificity of 87.2% (77.8, 95.1). In AD individuals, sensitivities of ST and IT RNFLT and BMO-MRW measurements below the 5th percentile criteria were lower than in ED individuals (RNFLT: 83.7% vs 92.5%, and BMO-MRW: 72.1% vs 88.5%, respectively), as well as specificities (AD RNFLT: 73.7% and BMO-MRW: 89.5% vs ED RNFLT: 96.4% and BMO-MRW: 98.2%, respectively). CONCLUSIONS: RNFLT and BMO-MRW had consistently lower diagnostic performance in AD individuals compared with ED individuals. BMO-MRW criteria might fail to detect as many as one-third of eyes with glaucoma, specifically in AD individuals. With the current reference database, RNFLT, and especially BMO-MRW, criteria are not adequate for diagnosing glaucoma in AD individuals.
引用
- El-Nimri NW, Moghimi S, Nishida T, et al. Racial Differences in Detection of Glaucoma Using Retinal Nerve Fiber Layer Thickness and Bruch Membrane Opening Minimum Rim Width. Am J Ophthalmol. 2022. PMID: 36662535. doi:10.1016/j.ajo.2022.10.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。