gonioscopic房角关闭眼中虹膜小梁接触的评估

Assessment of Iris Trabecular Contact in Eyes with Gonioscopic Angle-Closure.
PubMed 文献 · Ophthalmology · 2022-10-27

多中心前瞻性研究纳入119例健康对照和170例gonioscopic房角关闭患者,用AS-OCT测量ITC500范围并分析其与PAC/PACG的关联及诊断效能。ITC500≥10°检测gonioscopic房角关闭的敏感度为82.4%-84.7%、特异度85.7%。在gonioscopic房角关闭眼中,ITC500每增加10°,PAC/PACG的OR为1.049-1.051。

要点

  • ITC500≥10°检测gonioscopic房角关闭的敏感度为82.4%-84.7%,特异度为85.7%。
  • 在gonioscopic房角关闭眼中,ITC500每增加10°,PAC/PACG的OR为1.051(AOD500=0 mm)和1.049(TISA500=0 mm²)。
  • 轴长和前房深度与gonioscopic房角关闭眼中的PAC/PACG无显著关联(P≥0.574)。

核心结论

  • 在gonioscopic房角关闭眼中,AS-OCT测量的ITC范围越大(而非gonioscopy判定的房角关闭)与PAC/PACG的OR越高相关。

研究设计与样本

  • 多中心前瞻性研究,纳入119名gonioscopic开角健康参与者和170例gonioscopic房角关闭患者(94例PAC可疑、76例PAC/PACG)。
  • 每名受试者随机选择一只眼行AS-OCT成像,每10°测量AOD500和TISA500共360°。

主要发现

  • ITC500≥10°检测gonioscopic房角关闭的敏感度:AOD500=0 mm为82.4%,TISA500=0 mm²为84.7%。
  • ITC500≥10°检测gonioscopic房角关闭的特异度:AOD500=0 mm和TISA500=0 mm²均为85.7%。
  • 在gonioscopic房角关闭眼中,ITC500每增加10°,PAC/PACG的OR为1.051(AOD500=0 mm,95%CI 1.022-1.080)。
  • 在gonioscopic房角关闭眼中,ITC500每增加10°,PAC/PACG的OR为1.049(TISA500=0 mm²,95%CI 1.022-1.078)。
  • 在gonioscopic房角关闭眼中,轴长和前房深度与PAC/PACG无显著关联(P≥0.574)。

关键数值与推荐

  • ITC500的两种判定标准:AOD500=0 mm和TISA500=0 mm²。
  • AS-OCT测量的ITC500范围与gonioscopic房角关闭眼中PAC/PACG的OR相关,而累积gonioscopy评分(4个象限改良Shaffer分级之和)未显示此关联。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the extent of iris trabecular contact (ITC) measured by anterior segment OCT (AS-OCT) and its association with primary angle-closure (PAC) and PAC glaucoma (PACG) in eyes with gonioscopic angle-closure and to determine the diagnostic performance of ITC for detection of gonioscopic angle-closure. DESIGN: Multicenter, prospective study. PARTICIPANTS: A total of 119 healthy participants with gonioscopic open-angle and 170 patients with gonioscopic angle-closure (94 with PAC suspect and 76 with PAC/PACG) were included. METHODS: One eye of each subject was randomly selected for AS-OCT imaging. Angle-opening distance (AOD500) and trabecular iris space area (TISA500) were measured every 10° for 360°. Two criteria of ITC500 were examined: (1) AOD500 = 0 mm and (2) TISA500 = 0 mm2. The association between the extent of ITC500 and PAC/PACG in eyes with gonioscopic angle-closure was analyzed with logistic regression analysis. MAIN OUTCOME MEASURES: Sensitivity and specificity of ITC500 for detection of gonioscopic angle-closure; odds ratio (OR) of PAC/PACG. RESULTS: The sensitivity of ITC500 ≥ 10° for detection of gonioscopic angle-closure ranged from 82.4% (AOD500 = 0 mm) to 84.7% (TISA500 = 0 mm2), and the specificity was 85.7% (for both AOD500 = 0 mm and TISA500 = 0 mm2). The extent of ITC500 determined by AS-OCT, not cumulative gonioscopy score (i.e., the sum of the modified Shaffer grades over 4 quadrants), was associated with the odds of PAC/PACG in eyes with gonioscopic angle-closure; the odds of PAC/PACG increased by 5% for every 10° increase in ITC500 (OR, 1.051, 95% confidence interval [CI], 1.022-1.080 for AOD500 = 0 mm; OR, 1.049, 95% CI, 1.022-1.078 for TISA500 = 0 mm2). Axial length and anterior chamber depth were not associated with PAC/PACG in eyes with gonioscopic angle-closure (P ≥ 0.574). CONCLUSIONS: A greater extent of ITC measured by AS-OCT, not angle-closure determined by gonioscopy, was associated with a greater odds of PAC/PACG in eyes with gonioscopic angle-closure.