文献速递青光眼

疑似与确诊青光眼中神经节细胞层及内丛状层变化速率的比较

Comparison of Ganglion Cell Layer and Inner Plexiform Layer Rates of Change in Suspected and Established Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2022-12-11

前瞻性队列研究纳入64只疑似青光眼(GS)眼和112只确诊青光眼(EG)眼,随访≥2年且≥3次黄斑OCT扫描,用贝叶斯分层模型估计各超像素变化速率。结果显示GS组神经节细胞层(GCL)标准化变化速率快于内丛状层(IPL),EG组则IPL快于GCL,提示疑似早期青光眼损伤中IPL变薄并不早于GCL。

要点

  • 疑似青光眼组GCL标准化变化速率快于IPL(-0.69 vs -0.33)。
  • 确诊青光眼组IPL标准化变化速率快于GCL(-0.47 vs -0.28)。
  • 疑似青光眼组GCL显著负向变化超像素24/36,IPL为8/36(P < .001)。

核心结论

  • 在疑似青光眼中,GCL厚度较IPL更可能随时间出现变化;无证据表明疑似早期青光眼损伤眼存在IPL优先变薄。

研究设计与样本

  • 前瞻性队列研究,纳入64只疑似青光眼眼(46例患者)和112只确诊青光眼眼(112例患者),随访≥2年且≥3次黄斑OCT扫描。
  • 采用带随机截距/斜率及随机残差方差的贝叶斯分层模型估计各超像素的变化速率。

主要发现

  • 疑似青光眼组平均(SD)随访3.5(0.7)年、扫描4.2(1.0)次;确诊青光眼组为3.6(0.4)年、7.3(1.1)次。
  • 疑似青光眼组平均(SD)标准化变化速率GCL为-0.69(0.05),IPL为-0.33(0.04),GCL更快。
  • 确诊青光眼组平均(SD)标准化变化速率IPL为-0.47(0.03),GCL为-0.28(0.02),IPL更快。
  • 疑似青光眼组GCL变化速率显著为负的超像素为24/36,IPL为8/36(P < .001)。
  • 确诊青光眼组IPL变化速率显著为负的超像素为23/36,GCL为13/36(P = .006)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We compared ganglion cell layer (GCL) and inner plexiform layer (IPL) rates of change (RoC) in patients with glaucoma suspect (GS) and established glaucoma (EG) to test the hypothesis that IPL thickness changes would occur earlier than GCL changes in eyes with early damage. DESIGN: Prospective, cohort study. METHODS: A total of 64 GS eyes (46 patients) and 112 EG eyes (112 patients) with ≥2 years of follow-up and ≥3 macular optical coherence tomography scans were included. GCL and IPL superpixel thickness measurements were exported. A Bayesian hierarchical model with random intercepts/slopes and random residual variances was fitted to estimate RoC in individual superpixels. Normalized RoC and proportions of superpixels with significantly negative and positive GCL and IPL RoC were compared within the groups. RESULTS: The average (SD) follow-up time and number of scans were 3.5 (0.7) years and 4.2 (1.0), respectively, in the GS group and 3.6 (0.4) years and 7.3 (1.1) in the EG group. Mean (SD) normalized RoC was faster for GCL than IPL (-0.69 [0.05] vs -0.33 [0.04]) in the GS group, whereas it was faster for IPL (-0.47 [0.03] vs -0.28 [0.02]) in EG eyes. GCL RoC were significantly negative in 24 of 36 superpixels compared with 8 of 36 for IPL (P < .001) in GS eyes. In the EG group, 23 of 36 superpixels had significant negative IPL RoC compared with 13 of 36 superpixels for GCL (P = .006). CONCLUSIONS: GCL thickness is more likely to demonstrate change over time compared with IPL in glaucoma suspects. There is no evidence of preferential IPL thinning in eyes with suspected early glaucoma damage.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Mohammadi M, Su E, Chew L, et al. Comparison of Ganglion Cell Layer and Inner Plexiform Layer Rates of Change in Suspected and Established Glaucoma. Am J Ophthalmol. 2022. PMID: 36516918. doi:10.1016/j.ajo.2022.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。