文献速递青光眼眼底病与葡萄膜炎

黄斑OCT/OCTA与视野参数的长期变异性评估

Evaluation of the long-term variability of macular OCT/OCTA and visual field parameters.
PubMed 文献 · Br J Ophthalmol · 2024-01-29

研究纳入健康眼与青光眼眼(随访≥1年),评估黄斑OCT/OCTA及视野参数的长期变异性;稳定眼队列中OCT参数ICC最高(wiGCC=0.99),视野MD的长期重测变异性为2.2 dB,黄斑血管密度与GCC厚度变化分别超过4%-5%和2 µm提示可能进展。

要点

  • 稳定眼中OCT参数ICC最高(wiGCC=0.99),其次为视野MD(0.91)和OCTA wiVD(0.82)。
  • 视野MD、wiVD和wiGCC的长期重测变异性分别为2.2 dB、4.1%和2.2 µm。
  • 黄斑血管密度变化超过4%-5%、GCC厚度变化超过2 µm提示可能进展。

核心结论

  • 视野及黄斑OCT/OCTA(尤其OCT参数)在所有眼(包括稳定眼)中显示较小的长期变异性,支持这些仪器用于青光眼随访。
  • 黄斑血管密度和GCC厚度变化分别大于4%-5%和2 µm提示可能进展。

研究设计与样本

  • 纳入随访≥1年的健康眼和青光眼眼,分析24-2视野和黄斑OCT/OCTA参数(视野MD、全图像血管密度wiVD、全图像神经节细胞复合体厚度wiGCC)。
  • 对稳定眼队列(最长随访1.5年)计算组内相关系数(ICC)、均方根误差(RMSE)、个体内重测标准差(Sw)和重测变异性。
  • 在包含所有眼的扩展队列(随访不限)中评估变化率和RMSE。
  • 共230眼(150名参与者;年龄=67.7岁),其中86眼(37%,62名参与者)为稳定眼。
  • 扩展队列平均随访=3.0年。

主要发现

  • 稳定眼中OCT参数平均(95%)ICC最高(wiGCC=0.99(0.99,0.99)),其次为视野(视野MD=0.91(0.88,0.93))和OCTA(wiVD=0.82(0.75,0.87))。
  • 稳定眼中视野MD的RMSE和Sw分别为0.92 dB和0.81 dB,wiVD分别为1.64%和1.48%,wiGCC分别为0.91 µm和0.78 µm。
  • 视野MD、wiVD和wiGCC的长期重测变异性分别为2.2 dB、4.1%和2.2 µm。
  • 扩展队列中所有参数均有显著变化率(p<0.001),与稳定队列相比仅RMSE略高(视野MD=1.07 dB;wiGCC=2.03 µm;wiVD=2.57%)。

关键数值与推荐

  • 稳定眼中wiGCC的ICC为0.99(95%CI 0.99,0.99)。
  • 稳定眼中视野MD的ICC为0.91(95%CI 0.88,0.93)。
  • 稳定眼中wiVD的ICC为0.82(95%CI 0.75,0.87)。
  • 稳定眼中视野MD的RMSE为0.92 dB、Sw为0.81 dB;wiVD的RMSE为1.64%、Sw为1.48%;wiGCC的RMSE为0.91 µm、Sw为0.78 µm。
  • 视野MD、wiVD和wiGCC的长期重测变异性分别为2.2 dB、4.1%和2.2 µm。

临床怎么用

  • 原文结论认为这些仪器可用于青光眼随访。
  • 黄斑血管密度变化大于4%-5%、GCC厚度变化大于2 µm提示可能进展。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To assess the long-term variability of macular optical coherence tomography (OCT)/OCT angiography (OCTA) and visual field (VF) parameters. METHODS: Healthy and glaucoma eyes with ≥1-year follow-up were included. 24-2 VF and macular OCT/OCTA parameters, including VF mean deviation (MD), whole-image vessel density (wiVD) and ganglion cell complex thickness (wiGCC) were analysed. Intraclass correlation coefficient (ICC), root mean squared error (RMSE), within-subject test-retest SD (Sw) and test-retest variability were calculated for stable eye cohort (max follow-up=1.5 years). Rates of change and RMSE were evaluated in the extended cohort including all eyes (unlimited follow-up). RESULTS: From a total of 230 eyes (150 participants; age=67.7 years), 86 eyes (37%, 62 participants) were stable. In stable eyes, OCT parameters showed the highest mean (95%) ICC (wiGCC=0.99 (0.99, 0.99)), followed by VF (VF MD=0.91 (0.88, 0.93)) and OCTA (wiVD=0.82 (0.75, 0.87)). RMSE and Sw for VF MD were 0.92 dB and 0.81 dB, respectively, for wiVD were 1.64% and 1.48%, respectively, and for wiGCC, 0.91 µm and 0.78 µm, respectively. The long-term test-rest variability of VF MD, wiVD and wiGCC was 2.2 dB, 4.1% and 2.2 µm, respectively. In the extended cohort (mean follow-up=3.0 years), all parameters had significant rates of change (p<0.001), and compared with the stable cohort, only slightly higher RMSE (VF MD=1.07 dB; wiGCC=2.03 µm; wiVD=2.57%) were found. CONCLUSIONS: VF and macular OCT/OCTA, particularly OCT parameters, showed small long-term variability in all eyes, including stable ones, supporting the use of these instruments in glaucoma follow-up. Changes in macular VD and GCC greater than 4%-5% and 2 µm, respectively, indicate possible progression. TRIAL REGISTRATION NUMBER: NCT00221897.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wu JH, Moghimi S, Nishida T, et al. Evaluation of the long-term variability of macular OCT/OCTA and visual field parameters. Br J Ophthalmol. 2024. PMID: 36585126. doi:10.1136/bjo-2022-322470

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。