眼压升高加快青光眼黄斑血管密度丢失速率
基于诊断创新青光眼研究中的62例患者(59只原发性开角型青光眼眼和27只可疑青光眼眼,平均随访3.2年),评估眼压与黄斑全图像血管密度(wiVD)丢失及全图像神经节细胞复合体(wiGCC)变薄速率的关系。结果显示较高的平均眼压、峰值眼压和眼压波动与更快的wiVD丢失和wiGCC变薄相关,在峰值眼压<18 mmHg的眼中平均眼压较高仍与更快的wiVD和wiGCC进展相关。作者认为需要未来研究检验进一步降低眼压是否减少微血管丢失速率。
要点
- 较高的平均眼压、峰值眼压和眼压波动与更快的黄斑全图像血管密度丢失相关。
- 较高的平均眼压、峰值眼压和眼压波动与更快的全图像神经节细胞复合体变薄相关。
- 在峰值眼压<18 mmHg的眼中,较高的平均眼压仍与更快的wiVD和wiGCC进展相关。
核心结论
- 眼压指标与整体黄斑微血管丢失更快速率相关,在峰值眼压<18 mmHg的眼中也如此。
- 需要未来研究检验额外降低眼压是否减少青光眼患者的微血管丢失速率。
研究设计与样本
- 来自诊断创新青光眼研究的62例患者,包括59只原发性开角型青光眼眼和27只可疑青光眼眼,平均随访3.2年。
- 评估基于光学相干断层扫描血管成像(OCT-A)的血管密度和基于OCT的同一6×6 mm GCC扫描板的结构厚度。
- 对所有眼及峰值眼压<18 mmHg的子集进行单变量和多变量线性混合模型分析。
主要发现
- 较高的平均眼压(每1 mmHg -0.07%/年(95%CI -0.14至-0.01),p=0.033)、峰值眼压(每1 mmHg -0.07%/年(95%CI -0.13至-0.02),p=0.004)和眼压波动(眼压标准差)(每1 mmHg -0.17%/年(95%CI -0.32至0.02),p=0.026)与更快的黄斑血管密度丢失相关。
- 更快的wiGCC变薄与较高的平均眼压(每1 mmHg -0.05 µm/年(95%CI -0.10至-0.01),p=0.015)、峰值眼压(每1 mmHg -0.05 µm/年(95%CI -0.08至-0.02),p=0.003)和眼压波动(每1 mmHg -0.12 µm/年(95%CI -0.22至-0.01),p=0.032)相关。
- 在峰值眼压<18 mmHg的眼中,更快的wiVD进展与较高的平均眼压相关(p=0.042)。
- 在峰值眼压<18 mmHg的眼中,更快的wiGCC进展与较高的平均眼压相关(p=0.025)。
- 基线视野平均偏差(95%CI)为-3.3 dB(-4.4至-2.1)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需要未来研究检验额外降低眼压是否减少青光眼患者的微血管丢失速率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: To evaluate the relationship over time between intraocular pressure (IOP) and the rate of macula whole image vessel density (wiVD) loss and whole image ganglion cell complex (wiGCC) thinning in glaucoma METHODS: From 62 patients in the Diagnostic Innovations in Glaucoma Study, 59 Primary open-angle glaucoma and 27 glaucoma suspect eyes with mean follow-up of 3.2 years were followed. Optical coherence tomography angiography (OCT-A)-based vessel density and OCT-based structural thickness of the same 6×6 mm GCC scan slab were evaluated. Univariable and multivariable linear mixed models were performed for all eyes and also a subset of them in which peak IOP <18 mm Hg to investigate the effect of IOP parameters on the rate of wiVD and wiGCC change. RESULTS: The mean baseline visual field mean deviation (95% CI) was -3.3 dB (-4.4 to -2.1). Higher mean IOP (-0.07%/year per 1 mm Hg (-0.14 to -0.01), p=0.033), peak IOP (-0.07%/year per 1 mm Hg (-0.13 to -0.02), p=0.004) and IOP fluctuation (IOP SD) (-0.17%/year per 1 mm Hg (-0.32 to 0.02), p=0.026) were associated with faster macular vessel density loss. Faster wiGCC thinning was associated with higher mean IOP (-0.05 µm/year per 1 mm Hg (-0.10 to -0.01), p=0.015), peak IOP (-0.05 µm/year per 1 mm Hg (-0.08 to -0.02), p=0.003) and IOP fluctuation (-0.12 µm/year per 1 mm Hg (-0.22 to -0.01), p=0.032). In eyes with peak <18 mm Hg, faster wiVD progression was associated with higher mean IOP (p=0.042). Faster wiGCC progression was associated with higher mean IOP in these eyes (p=0.025). CONCLUSION: IOP metrics were associated with faster rates of overall macular microvascular loss and also in the eyes with peak IOP <18 mm Hg. Future studies are needed to examine whether additional IOP lowering reduces the rate of microvascular loss in patients with glaucoma. TRIAL REGISTRATION NUMBER: NCT00221897.
引用
- Mahmoudinezhad G, Moghimi S, Nishida T, et al. Intraocular pressure increases the rate of macular vessel density loss in glaucoma. Br J Ophthalmol. 2024. PMID: 36535749. doi:10.1136/bjo-2022-322261
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。