文献速递眼底病与葡萄膜炎

视网膜下玻璃膜疣样沉积物的荧光寿命与光谱特征及其对年龄相关性黄斑变性进展的预测价值

Fluorescence Lifetime and Spectral Characteristics of Subretinal Drusenoid Deposits and Their Predictive Value for Progression of Age-Related Macular Degeneration.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2022-01-01

本研究对30只经OCT确认的早期或中期年龄相关性黄斑变性(AMD)伴视网膜下玻璃膜疣样沉积物(SDD)患眼行荧光寿命成像检眼镜检查,测量SDD及其周围环境的荧光寿命与峰值发射波长。基线共发现423个SDD,其短波长通道荧光寿命较周围环境延长14.5 ps(95%CI 13.3-15.7 ps),峰值发射波长缩短1.53 nm(95%CI 1.07-1.98 nm)。基线短波长通道寿命对比值较高与疾病进展至晚期AMD相关。

要点

  • SDD的荧光寿命较周围环境延长,短波长通道延长14.5 ps,长波长通道延长3.9 ps。
  • SDD的峰值发射波长较周围环境缩短1.53 nm,高自发荧光SDD的对比更明显。
  • 基线短波长通道寿命对比值较高与进展至晚期AMD相关(15.9 ps vs 11.7 ps,P < 0.001)。

核心结论

  • SDD的眼底自发荧光寿命较其周围环境延长,峰值发射波长较其周围环境缩短。
  • SDD在短波长通道的高寿命对比值可能预测疾病进展至晚期AMD。

研究设计与样本

  • 对30只经OCT确认的早期或中期AMD伴SDD患眼行荧光寿命成像检眼镜检查(FLIO)。
  • 在基线及随访1(13-36个月)和随访2(37-72个月)测量SDD及其环境的短波长通道和长波长通道平均寿命、峰值发射波长及相对荧光强度的对比值。

主要发现

  • 基线共发现423个SDD,其中低自发荧光259个、等自发荧光47个、高自发荧光117个。
  • SDD的荧光寿命较其环境显著延长:短波长通道延长14.5 ps(95%CI 13.3-15.7 ps),长波长通道延长3.9 ps(95%CI 3.1-4.7 ps)。
  • SDD的峰值发射波长较其环境缩短1.53 nm(95%CI 1.07-1.98 nm),所有对比P < 0.001,高荧光SDD的对比更高。
  • 随访2中SDD相对荧光强度增加3.4%(95%CI 2.9%-4.1%,P < 0.001),趋向高自发荧光。
  • 高自发荧光与OCT上椭圆体带破坏相关;进展至晚期AMD者基线短波长通道寿命对比值为15.9 ps(95%CI 14.2-17.6 ps),未进展者为11.7 ps(95%CI 9.9-13.5 ps),P < 0.001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To measure fundus autofluorescence (FAF) lifetimes and peak emission wavelengths (PEW) of subretinal drusenoid deposits (SDD) in age-related macular degeneration (AMD) and their development over time. METHODS: Fluorescence lifetime imaging ophthalmoscopy (FLIO) was performed in 30 eyes with optical coherence tomography (OCT)-confirmed early or intermediate AMD and SDD. Contrasts of mean lifetimes in short- (SSC) and long-wavelength channels (LSC), PEW, and relative fluorescence intensity were determined as differences of the respective measures at individual SDD and their environment. Measurements were made at baseline and at follow-up intervals 1 (13-36 months) and 2 (37-72 months), respectively. RESULTS: Of 423 SDD found at baseline, 259, 47, and 117 were hypoautofluorescent, isoautofluorescent, and hyperautofluorescent, respectively. FAF lifetimes of SDD were significantly longer than those of their environment by 14.5 ps (SSC, 95% confidence interval [CI], 13.3-15.7 ps) and 3.9 ps (LSC, 3.1-4.7 ps). PEW was shorter by 1.53 nm (1.07-1.98 nm, all contrasts P < 0.001) with higher contrasts for hyperfluorescent SDD. Over follow-up, SDD tended to hyperautofluorescence (relative intensities increased by 3.4% [95% CI, 2.9%-4.1%; P < 0.001] in follow-up 2). Hyperautofluorescence was associated with disruption of the ellipsoid zone on OCT. Disease progression to late-stage AMD was associated with higher lifetime contrast in SSC (15.9ps [14.2-17.6 ps] vs. 11.7 ps [9.9-13.5 ps], P < 0.001) at baseline. CONCLUSIONS: SDD show longer FAF lifetimes and shorter PEW than their environments. A high lifetime contrast of SDD in SSC might predict disease progression to late-stage AMD.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Weber S, Simon R, Schwanengel LS, et al. Fluorescence Lifetime and Spectral Characteristics of Subretinal Drusenoid Deposits and Their Predictive Value for Progression of Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2022. PMID: 36580310. doi:10.1167/iovs.63.13.23

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。