文献速递眼底病与葡萄膜炎

年龄相关性黄斑变性中的色素沉着异常:与进展的关联及对视觉敏感度的影响

Hyperpigmentary abnormalities in age-related macular degeneration: association with progression and impact on visual sensitivity.
PubMed 文献 · Br J Ophthalmol · 2024-01-29

研究纳入140例双侧大玻璃膜疣患者,基线及每6个月行多模式影像和微视野检查至3年,评估彩色眼底照相定义的色素沉着异常(HPA)范围量化较其单纯存在对预测晚期年龄相关性黄斑变性(AMD)的附加价值及其与视觉敏感度的关联。结果显示HPA存在与范围对晚期AMD的预测性能无显著差异(p=0.92);各扇区HPA范围增加与扇区视觉敏感度降低相关(p<0.001),而全眼总范围与总体视觉敏感度无关(p=0.671)。

要点

  • 量化HPA范围较其单纯存在未改善对晚期AMD发生的预测(p=0.92)。
  • 各扇区HPA范围增加与扇区视觉敏感度降低相关(p<0.001)。
  • 全眼HPA总范围与总体视觉敏感度无显著关联(p=0.671)。

核心结论

  • 在双侧大玻璃膜疣队列中,量化HPA范围较其单纯存在未改善对晚期AMD发生的预测。
  • HPA范围与更局限而非全面的视觉敏感度降低相关。
  • 这些发现提示量化HPA范围对预测AMD进展附加价值很小,但可提供视觉功能障碍的影像生物标志物。

研究设计与样本

  • 140例双侧大玻璃膜疣参与者,基线及之后每6个月行多模式影像和微视野检查,随访至3年。
  • 基线彩色眼底照相评估HPA存在并量化其范围,OCT用于量化玻璃膜疣体积。
  • 使用HPA存在或范围构建预测晚期AMD(包括OCT萎缩征象)的模型,并评估HPA范围与平均视觉敏感度(总体及分扇区)的关联。
  • 所有模型均校正基线年龄和玻璃膜疣体积等混杂因素。

主要发现

  • HPA存在与范围对晚期AMD发生的预测性能无显著差异(p=0.92)。
  • 各扇区HPA范围增加与扇区视觉敏感度降低相关(p<0.001)。
  • 全眼HPA总范围与总体视觉敏感度无显著关联(p=0.671)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To investigate the additional prognostic value of quantifying the extent of colour fundus photography (CFP)-defined hyperpigmentary abnormalities (HPAs) compared with their presence alone for predicting progression to late-stage age-related macular degeneration (AMD) and to understand their association with visual sensitivity in individuals with intermediate AMD. METHODS: 140 participants with bilateral large drusen underwent multimodal imaging and microperimetry at baseline and then every 6 months for up to 3 years. Baseline CFPs were graded for the presence of HPAs and their extent was quantified. Optical coherence tomography (OCT) scans were used to quantify drusen volume. Predictive models for progression to late AMD (including OCT signs of atrophy) were developed using either HPA presence or extent. The association between HPA extent with mean visual sensitivity (both overall and sector based) was also evaluated. All models were adjusted for the confounders of baseline age and drusen volume. RESULTS: The predictive performance for late AMD development was not significantly different for HPA presence or extent (p=0.92). Increasing HPA extent in each sector, but not its overall extent in an eye, was associated with reduced sector-based visual sensitivity (p<0.001 and p=0.671, respectively). CONCLUSION: In a cohort with bilateral large drusen, quantifying HPA extent did not improve the prediction of late AMD development compared with presence alone. HPA extent was associated with more local, rather than generalised, reductions in visual sensitivity. These findings suggest that quantification of HPA extent adds little to the prediction of AMD progression, but that it provides an imaging biomarker of visual dysfunction.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Goh KL, Kumar H, Hadoux X, et al. Hyperpigmentary abnormalities in age-related macular degeneration: association with progression and impact on visual sensitivity. Br J Ophthalmol. 2024. PMID: 36564147. doi:10.1136/bjo-2022-322676

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。