系统综述与Meta分析:后弹力层内皮角膜移植术与超薄后弹力层剥离自动内皮角膜移植术的结局比较
该系统综述与Meta分析比较了超薄后弹力层剥离(自动)内皮角膜移植术与后弹力层内皮角膜移植术治疗Fuchs内皮营养不良和角膜大泡性病变的疗效与安全性,共纳入7项研究。后弹力层内皮角膜移植术组术后12个月最佳矫正视力更优,但再气泡处理率更高;其余参数组间无显著差异,但估计值不精确。
要点
- 后弹力层内皮角膜移植术组术后12个月最佳矫正视力优于超薄后弹力层剥离(自动)内皮角膜移植术组(SMD=0.50,95%CI 0.27-0.74)。
- 后弹力层内皮角膜移植术组再气泡处理率高于超薄后弹力层剥离(自动)内皮角膜移植术组(RR=0.33,95%CI 0.16-0.67)。
- 移植失败、移植排斥和术后眼压升高的组间差异均无统计学显著性,但估计值不精确。
核心结论
- 后弹力层内皮角膜移植术组术后最佳矫正视力优于超薄后弹力层剥离(自动)内皮角膜移植术组,但再气泡处理率更高;除再气泡处理外,两种手术的并发症发生率相当。
研究设计与样本
- 系统综述与Meta分析,检索Cochrane系统综述数据库、PubMed、EMBASE、LILACS并手工检索参考文献,最终纳入7项研究。
主要发现
- 后弹力层内皮角膜移植术组术后12个月最佳矫正视力优于超薄后弹力层剥离(自动)内皮角膜移植术组(SMD=0.50,95%CI 0.27-0.74)。
- 后弹力层内皮角膜移植术组再气泡处理率高于超薄后弹力层剥离(自动)内皮角膜移植术组(RR=0.33,95%CI 0.16-0.67)。
- 移植失败(RR=0.65,95%CI 0.18-2.30)、移植排斥(RR=1.40,95%CI 0.27-7.30)和术后眼压升高(RR=1.14,95%CI 0.60-2.18)的组间差异均无统计学显著性,但估计值不精确。
- 术后内皮细胞密度的标准化均数差因研究间异质性显著而无法评估。
局限性
- 术后内皮细胞密度的标准化均数差因研究间异质性显著而无法评估。
- 移植失败、移植排斥和术后眼压升高的估计值不精确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the efficacy and safety of ultrathin Descemet stripping (automated) endothelial keratoplasty (UT-DS(A)EK) versus Descemet membrane endothelial keratoplasty (DMEK) for the treatment of Fuchs endothelial dystrophy (FED) and bullous keratopathy (BK). DESIGN: Systematic review and meta-analysis. METHODS: Literature containing DMEK and UT-DSAEK were searched in the Cochrane Database of Systematic Reviews, PubMed, EMBASE, LILACS, and through manual reference searching. Studies were included that measured the outcome of interventions-including best corrected visual acuity (BCVA), endothelial cell density (ECD), and postoperative complications, especially graft detachment with the need of re-bubbling, graft rejection, graft failure, and postoperative elevated intraocular pressure (IOP)-in patients with FED and BK. Included outcomes were pooled as standardized mean differences (SMD) or risk ratios (RR) using random effects models. Inter-study heterogeneity was assessed using the Q-test and I2 statistic. RESULTS: Seven (of 163) studies met all the inclusion and exclusion criteria. Meta-analysis showed a significantly better BCVA 12 months postoperatively, but an increased re-bubbling rate in eyes after DMEK compared with eyes after UT-DS(A)EK (BCVA: SMD = 0.50 [95% CI 0.27-0.74] and re-bubbling rate: RR = 0.33 [95% CI 0.16-0.67]). All other parameters did not differ significantly between both interventions, although estimates were imprecise (graft failure: RR = 0.65 [95% CI 0.18-2.30], graft rejection: RR = 1.40 [95% CI 0.27-7.30], and postoperative intraocular pressure elevation: RR = 1.14 [95% CI 0.60-2.18]). Postoperative SMDs of ECD could not be evaluated due to significant heterogeneity between studies. CONCLUSIONS: Although the improvement in BCVA was higher after UT-DS(A)EK than after conventional DS(A)EK, the BCVA after DMEK was still superior. The complication rates were comparable for both procedures, except for the higher rate of re-bubbling after DMEK.
引用
- Maier AB, Milek J, Joussen AM, et al. Systematic Review and Meta-analysis: Outcomes After Descemet Membrane Endothelial Keratoplasty Versus Ultrathin Descemet Stripping Automated Endothelial Keratoplasty. Am J Ophthalmol. 2022. PMID: 36220351. doi:10.1016/j.ajo.2022.09.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。