文献速递白内障与屈光手术

小眼球与相对性前段小眼球中人工晶状体计算公式准确性的比较研究

A Comparative Study on the Accuracy of IOL Calculation Formulas in Nanophthalmos and Relative Anterior Microphthalmos.
PubMed 文献 · Am J Ophthalmol · 2022-09-07

回顾性病例系列纳入26只小眼球眼(眼轴16.84±1.36 mm)和12只相对性前段小眼球眼(角膜直径8.41±0.92 mm),比较6种人工晶状体计算公式的预测误差。小眼球组中Haigis公式优化前中位绝对预测误差最小(1.61 D,P<0.001),优化后在±0.25 D、±0.5 D和±1 D内的比例最高;相对性前段小眼球组各公式优化前后均无显著差异。

要点

  • 小眼球白内障患者省略晶状体厚度参数计算时,Haigis公式在6种公式中最准确。
  • 相对性前段小眼球患者中,优化后Barrett Universal II公式在±1 D和±2 D内的比例最高。
  • 小眼球组整体预测结果向近视偏移,相对性前段小眼球组整体预测结果与0无显著差异。

核心结论

  • 省略晶状体厚度参数计算时,6种人工晶状体计算公式中小眼球(眼轴<20 mm)白内障患者使用Haigis公式最准确。
  • 相对性前段小眼球(角膜直径≤9.5 mm)白内障患者中Barrett Universal II公式准确性最高。

研究设计与样本

  • 回顾性病例系列,纳入26只小眼球眼(眼轴16.84±1.36 mm,范围15.25 mm-19.82 mm)和12只相对性前段小眼球眼(角膜直径8.41±0.92 mm,范围7.00 mm-9.50 mm)行白内障手术。
  • 使用IOL Master 500进行生物测量,因此人工晶状体度数计算中省略晶状体厚度参数。
  • 比较6种原始公式(Haigis、Hoffer Q、Holladay I、SRK/T、Barrett Universal II和Hoffer QST)的平均和中位算术及绝对预测误差、优化后6种公式的绝对预测误差,以及各公式预测误差在±0.25 D、±0.5 D、±1 D和±2 D内的比例。
  • 采用多因素回归分析影响预测误差的因素。

主要发现

  • 小眼球组整体预测结果向近视偏移,原始Haigis公式中位绝对预测误差最小(1.61 D,P<0.001)。
  • 小眼球组优化后Haigis公式预测误差在±0.25 D、±0.5 D和±1 D内的比例最高。
  • 相对性前段小眼球组整体预测结果与0无显著差异(P>.05)。
  • 相对性前段小眼球组优化前各公式间无显著差异(P=.146),优化后亦无显著差异(P=.161),但优化后Barrett Universal II公式预测误差在±1 D和±2 D内的比例最高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We sought to compare the prediction accuracy of 6 intraocular lens (IOL) formulas, namely, the Haigis, Hoffer Q, Holladay I, SRK/T, Barrett Universal II and Hoffer QST formulas, in microphthalmic eyes, including those with nanophthalmos and relative anterior microphthalmos (RAM). DESIGN: Retrospective case series. METHODS: Twenty-six eyes with nanophthalmos (axial length [AL] 16.84 ± 1.36 mm, range 15.25 mm-19.82 mm) and 12 eyes with RAM (corneal diameter 8.41 ± 0.92 mm, range 7.00 mm-9.50 mm) receiving cataract surgery were included. The IOL Master 500 was used for biometry; thus, lens thickness (LT) was omitted in the IOL power calculation. The mean and median arithmetic and absolute prediction errors (PEs) of the 6 original calculation formulas, the absolute PEs of the 6 formulas after optimization, and the proportion of PEs within ±0.25 diopters (D), ±0.5 D, ±1 D, and ±2 D with each formula were compared. The factors influencing PE were analyzed by multivariate regression. RESULTS: In the nanophthalmos group, the overall prediction results were shifted to myopia. The original Haigis formula had the smallest median absolute PE (1.61 D, P < 0.001), and the optimized Haigis formula had the highest proportion of PEs within ±0.25 D, ±0.5 D, and ±1 D. In the RAM group, the overall prediction results were not significantly different from 0 (P > .05). No significant difference was found among the formulas before optimization (P = .146) and after optimization (P = .161), but the optimized Barrett Universal II formula had the highest proportion of PEs within ±1 D and ±2 D. CONCLUSIONS: When omitting the LT parameter in the calculation, the Haigis formula was the most accurate in cataract patients with nanophthalmos (AL <20 mm) among the 6 IOL calculation formulas, and the Barrett Universal II formula had the highest accuracy in cataract patients with RAM (corneal diameter ≤9.5 mm).

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lin P, Xu J, Miao A, et al. A Comparative Study on the Accuracy of IOL Calculation Formulas in Nanophthalmos and Relative Anterior Microphthalmos. Am J Ophthalmol. 2022. PMID: 36084681. doi:10.1016/j.ajo.2022.08.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。