文献速递白内障与屈光手术青光眼

单独超声乳化白内障吸除术后眼压变化:IRIS注册登记分析

Intraocular Pressure Changes Following Stand-Alone Phacoemulsification: An IRISɌ Registry Analysis.
PubMed 文献 · Am J Ophthalmol · 2022-09-24

基于IRIS注册登记中1,334,868例接受单独超声乳化白内障吸除术且对侧眼后续行白内障手术的患者,比较手术眼与对侧有晶状体眼术后第1至90天每日平均眼压。术后第13天起手术眼每日平均眼压持续显著低于对照眼至第90天(P < .001)。全部手术眼最终平均眼压较基线平均(SD)下降1.55(3.52)mm Hg(7.79%)。

要点

  • 术后早期手术眼每日平均眼压因眼压峰值高于对照眼。
  • 术后第13天至第90天手术眼每日平均眼压均显著低于对侧有晶状体眼(P < .001)。
  • 全部手术眼最终平均眼压较基线平均(SD)下降1.55(3.52)mm Hg(7.79%)。

核心结论

  • 伴有和不伴有青光眼的眼行单独超声乳化白内障吸除术后,术后90天内眼压较基线和对侧有晶状体眼显著下降。

研究设计与样本

  • 回顾性临床队列研究,纳入IRIS®注册登记中2013年1月1日至2019年9月30日接受单独超声乳化白内障吸除术且对侧眼后续行白内障手术的患者共1,334,868例,其中青光眼336,060例、无青光眼998,808例。
  • 比较手术眼与对照眼术后第1天至第90天的每日平均眼压,并用广义线性模型确定术后每日平均眼压稳定时间以计算最终平均眼压,再与基线眼压比较。

主要发现

  • 术后每日平均眼压初期手术眼高于对照眼,系术后早期眼压峰值所致。
  • 至术后第13天,手术眼每日平均眼压显著低于对照眼,并持续至术后第90天(P < .001)。
  • 全部手术眼最终平均眼压较基线平均(SD)下降1.55(3.52)mm Hg(7.79%)。
  • 伴青光眼手术眼最终平均眼压较基线平均(SD)下降1.91(3.93)mm Hg(8.89%)。
  • 不伴青光眼手术眼最终平均眼压较基线平均(SD)下降1.37(3.28)mm Hg(7.24%)。

关键数值与推荐

  • 全部手术眼、不伴青光眼手术眼及各类前青光眼和青光眼(葡萄膜炎性青光眼除外,P = .0016)最终平均眼压较基线下降均有统计学显著性(P < .0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe real-world intraocular pressure (IOP) changes following stand-alone cataract surgery by comparing postoperative IOP to phakic fellow eyes. DESIGN: Retrospective clinical cohort study. METHODS: A total of 1,334,868 patients (336,060 with glaucoma and 998,808 without glaucoma) in the IRIS® Registry (Intelligent Research in Sight) underwent stand-alone phacoemulsification from 1 January 2013 to 30 September 2019 with a fellow eye that had subsequent cataract surgery. Postoperative daily mean IOP was compared between surgical and control eyes from postoperative day 1 to 90. A generalized linear model determined when the postoperative daily mean IOP stabilized to calculate a final mean IOP, which was then compared to baseline IOP. RESULTS: Postoperative daily mean IOP was initially greater for surgical than for control eyes because of an early postoperative IOP spike. By postoperative day 13, postoperative daily mean IOP was significantly lower for surgical than for control eyes every day through postoperative day 90 (P < .001). There was a mean (SD) decrease from baseline to final mean IOP of 1.55 (3.52) mm Hg or 7.79% for all surgical eyes, 1.91 (3.93) mm Hg or 8.89% for surgical eyes with glaucoma, and 1.37 (3.28) mm Hg or 7.24% for surgical eyes without glaucoma, respectively. There was a statistically significant decrease from baseline to the final mean IOP for all surgical eyes, surgical eyes without glaucoma, and all categories of pre-glaucoma and glaucoma (P < .0001 for all, excluding uveitic glaucoma [P = .0016]). CONCLUSIONS: Eyes both with and without glaucoma that underwent stand-alone phacoemulsification had a significant decrease in IOP through the 90-day postoperative period compared to baseline and phakic fellow eyes.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。