文献速递眼底病与葡萄膜炎

充气性视网膜固定术后黄斑下积液对孔源性视网膜脱离修复的临床与结构影响

CLINICAL AND STRUCTURAL IMPACT OF SUBMACULAR FLUID AFTER PNEUMATIC RETINOPEXY REPAIR FOR RHEGMATOGENOUS RETINAL DETACHMENT.
PubMed 文献 · Retina · 2023-01-01

回顾性分析387眼(374例)因原发性孔源性视网膜脱离接受充气性视网膜固定术的连续患者,其中166眼术后成功并完成OCT检查。黄斑下积液发生于59眼(35.5%),与黄斑脱离及晶状体眼状态相关,平均9.39个月吸收,伴术前视力更差及视力恢复延迟。最终视力SMF组0.277 logMAR(20/40)vs 无SMF组0.162 logMAR(20/30)(P<.001),但最终差异较小。

要点

  • OCT检测的黄斑下积液在充气性视网膜固定术成功后常见(35.5%),与黄斑脱离和晶状体眼状态相关。
  • 黄斑下积液平均9.39个月吸收,与术前BCVA更差及视力恢复延迟相关。
  • 黄斑下积液与吸收后光感受器外段结构不连续相关,椭圆体带不连续与视力预后更差相关。

核心结论

  • OCT检测的微量黄斑下积液在充气性视网膜固定术成功后常见,导致视力恢复延迟及积液吸收后视网膜外层不连续率增加。
  • 尽管有上述影响,有无黄斑下积液眼之间的最终最佳矫正视力差异较小。

研究设计与样本

  • 回顾性 Review of consecutive patients treated with pneumatic retinopexy for primary rhegmatogenous retinal detachment repair。
  • 共纳入387眼(374例患者),其中166眼在充气性视网膜固定术成功后接受OCT成像。

主要发现

  • 黄斑下积液发生于59眼(35.5%),与黄斑脱离(P≤.001)及晶状体眼状态(P=.007)相关。
  • 黄斑下积液平均9.39个月吸收,与术前最佳矫正视力更差及视力恢复延迟相关。
  • 最终平均最佳矫正视力:有黄斑下积液眼0.277 logMAR(20/40)vs 无黄斑下积液眼0.162 logMAR(20/30)(P<.001)。
  • 黄斑下积液与积液吸收后光感受器内外段交界带不连续(P=.003)、椭圆体带不连续(P=.005)及外界膜不连续(P≤.001)相关。
  • 椭圆体带不连续与视力预后更差相关(P=.009)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the impact of submacular fluid (SMF) after pneumatic retinopexy for primary rhegmatogenous retinal detachment repair. METHODS: Retrospective review of consecutive patients treated with pneumatic retinopexy for primary rhegmatogenous retinal detachment repair. 387 eyes (374 patients) were included, of which 166 underwent optical coherence tomography imaging after successful pneumatic retinopexy. Foveal-centered optical coherence tomography scans were reviewed. RESULTS: SMF occurred in 59 eyes (35.5%) and was associated with macular detachment ( P ≤ 0.001) and phakic lens status ( P = 0.007). Submacular fluid resolved over an average of 9.39 months and was associated with worse preprocedure best-corrected visual acuity and delayed visual recovery. The mean final best-corrected visual acuity was 0.277 logarithm of the minimum angle of resolution (20/40) in eyes with SMF and 0.162 logarithm of the minimum angle of resolution (20/30) in those without SMF ( P < 0.001). Submacular fluid was associated with discontinuity of the interdigitation zone ( P = 0.003), ellipsoid zone ( P = 0.005), and external limiting membrane ( P ≤ 0.001) after SMF resolution. Ellipsoid zone discontinuity was associated with worse visual prognosis ( P = 0.009). CONCLUSION: Trace SMF detected by optical coherence tomography is common after successful pneumatic retinopexy and resulted in delayed visual recovery and increased rates of outer retinal discontinuity after SMF resorption, although the final difference in best-corrected visual acuity in those with and without SMF was minimal.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Carrera WM, Peng MY, Reddy M, et al. CLINICAL AND STRUCTURAL IMPACT OF SUBMACULAR FLUID AFTER PNEUMATIC RETINOPEXY REPAIR FOR RHEGMATOGENOUS RETINAL DETACHMENT. Retina. 2023. PMID: 36165951. doi:10.1097/IAE.0000000000003635

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。