学龄期儿童的眨眼与正常眼表及年龄和屏幕时间的影响
一项横断面研究纳入45名6-15岁儿童,使用可穿戴眼动追踪头戴设备在体测量眨眼率与瞬目间隔,评估眼表症状和临床指标。结果显示平均眨眼率20.5±10.5次/分、瞬目间隔2.9±1.9秒,眨眼与数字设备使用、年龄或性别无关;泪液量较多与更快的眨眼率相关,年龄较大与泪液量和泪膜稳定性改善相关。
要点
- 学龄期儿童对话时平均眨眼率为20.5±10.5次/分,瞬目间隔为2.9±1.9秒。
- 眨眼率与习惯性数字设备使用、年龄或性别无关。
- 泪液量较大与更快的眨眼率相关,但眨眼与眼表症状无关。
核心结论
- 在体测量的眨眼不受年龄或习惯性数字设备使用的影响。
- 更快的眨眼率与更大的泪液量相关,但与症状无关。
- 泪膜功能随年龄改善,提示眼表在儿童期持续发育。
研究设计与样本
- 横断面研究,纳入45名6-15岁儿童,女性占56%。
- 使用可穿戴眼动追踪头戴设备(Pupil Labs GmbH,德国)在体测量眨眼率和瞬目间隔。
- 评估眼表症状问卷和临床指标(脂质层厚度、泪液分泌和稳定性、睑板腺)。
主要发现
- 对话时平均眨眼率为20.5±10.5次/分,平均瞬目间隔为2.9±1.9秒。
- 自动与手动计数眨眼率无差异(p=0.78)。
- 眨眼与数字设备使用、年龄或性别无关。
- 泪液量较大与更快的眨眼率相关(r=0.46,p=0.001),与更短的瞬目间隔相关(r=-0.36,p=0.02)。
- 年龄较大与泪液量改善(r=0.37,p=0.01)和泪膜稳定性改善(r=0.38,p=0.01)相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Baseline ocular surface characteristics in children require investigation. This study characterised blinking and relationships with ocular symptoms, tear film and digital device use. METHODS: 45 children aged 6-15 years (56% female) participated in a cross-sectional study. Ocular surface symptoms (Instant Ocular Symptoms Survey, Dry Eye Questionnaire 5, Symptoms Assessment in Dry Eye, Ocular Surface Disease Index, Ocular Comfort Index and Numerical Rating Scale) and clinical indices (lipid layer thickness, tear secretion and stability, meibomian gland) were assessed. Blink rate and interblink interval were measured in situ using a wearable eye-tracking headset (Pupil Labs GmbH, Germany). Associations between blinking, ocular surface, age, and digital device use (bivariate and partial correlations) and between automated and manually counted blink rate (Bland & Altman) were examined. RESULTS: Mean blink rate and interblink interval were 20.5±10.5 blinks/min and 2.9±1.9 s during conversation. There was no difference between automated and manual blink rate (p=0.78) and no relationship between blinking and digital device use, age or sex. Mean group symptoms were within normal range and not associated with clinical measurements including blinking. Greater tear volume was associated with a faster blink rate (r=0.46, p=0.001) and shorter interblink interval (r=-0.36, p=0.02). Older age was associated with improved tear volume (r=0.37, p=0.01) and stability (r=0.38, p=0.01). CONCLUSIONS: Blinking characterised in situ was not impacted by age or habitual digital device use. A faster blink rate was associated with greater tear volume but not symptoms. Improved tear function was found with age suggesting that the ocular surface continues to develop through childhood.
引用
- Chidi-Egboka NC, Jalbert I, Wagner P, et al. Blinking and normal ocular surface in school-aged children and the effects of age and screen time. Br J Ophthalmol. 2022. PMID: 36002237. doi:10.1136/bjo-2022-321645
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。