文献速递青光眼神经眼科

Spectralis OCT逐层偏差图的临床实用性:与Cirrus OCT的比较

Clinical usefulness of layer-by-layer deviation maps of Spectralis OCT: comparison with Cirrus OCT.
PubMed 文献 · Br J Ophthalmol · 2022-08-24

本横断面研究纳入144只眼(47只健康眼、43只青光眼前期眼、54只早期青光眼眼),同日行Spectralis与Cirrus OCT检查,比较两者逐层偏差图检测视网膜神经纤维层缺损的诊断能力。结果显示除Spectralis的IPL层外,两者各层偏差图均具有良好诊断能力,均可用于青光眼前期和早期青光眼的RNFL缺损检测。

要点

  • Spectralis的RNFL、GCL及视网膜层与Cirrus的RNFL及黄斑GCIPL层诊断AUC均>0.8
  • Cirrus的RNFL层AUC最大(PPG 0.840,EG 0.959),但与Spectralis的RNFL及视网膜层无统计学差异
  • Spectralis的IPL层AUC最小(PPG 0.563,EG 0.799)

核心结论

  • 除Spectralis的IPL层外,Spectralis与Cirrus OCT偏差图均显示良好诊断能力。
  • 在临床环境中,Spectralis与Cirrus OCT均可用于检测PPG和EG眼的RNFL缺损。

研究设计与样本

  • 横断面研究,共纳入144名参与者的144只眼(47只健康眼、43只PPG眼、54只EG眼;MD≥-6 dB)。
  • 所有眼同日行Spectralis与Cirrus OCT检查,并评估无赤光RNFL照相及各自偏差图上的RNFL缺损。

主要发现

  • Spectralis的RNFL、GCL和视网膜层及Cirrus的RNFL和黄斑GCIPL层在区分PPG和EG眼与健康眼时均显示高诊断性能(所有AUC>0.8)。
  • Cirrus的RNFL层AUC最大(PPG为0.840,EG为0.959),但与Spectralis的RNFL和视网膜层无统计学差异。
  • Spectralis的IPL层AUC最小(PPG为0.563,EG为0.799)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To compare the diagnostic abilities of Spectralis (Heidelberg Engineering, Heidelberg, Germany) and Cirrus (Carl Zeiss Meditec, Dublin, California, USA) spectral domain-optical coherence tomography (OCT) for retinal nerve fibre layer (RNFL) defect detection among patients with preperimetric glaucoma (PPG) and early glaucoma (EG). METHODS: In this cross-sectional study, a total of 144 eyes (47 healthy, 43 PPG, 54 EG; MD≥-6 dB) of 144 participants underwent Spectralis and Cirrus OCT on the same day. The presence of RNFL defect on red-free RNFL photography and the respective deviation maps of Spectralis and Cirrus OCT was rated. Areas under the receiver operating characteristic curves (AUCs), sensitivities and specificities were analysed for each deviation layer to discriminate healthy eyes from PPG and EG eyes. RESULTS: The RNFL, ganglion cell layer (GCL) and retinal layers of Spectralis OCT and the RNFL and macular ganglion cell-inner plexiform layer of Cirrus OCT showed high diagnostic performance (all AUCs >0.8) in discriminating PPG and EG eyes from healthy eyes. Among them, RNFL layer of Cirrus OCT had the largest AUC (0.840 for PPG, 0.959 for EG) but showed no statistical differences from RNFL and retinal layers of Spectralis OCT. The inner plexiform layer (IPL) of Spectralis OCT had the smallest AUC (0.563 for PPG, 0.799 for EG). CONCLUSIONS: The Spectralis and Cirrus OCT deviation maps showed good diagnostic abilities except for the IPL layer of Spectralis. In the clinical setting, both Spectralis and Cirrus OCT can be useful for detection of RNFL defects in PPG and EG eyes.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Choe S, Jang M, Kim YK, et al. Clinical usefulness of layer-by-layer deviation maps of Spectralis OCT: comparison with Cirrus OCT. Br J Ophthalmol. 2022. PMID: 36002236. doi:10.1136/bjo-2022-321054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。