文献速递神经眼科

利用超声测量视神经蛛网膜下腔面积无创评估颅内压

Non-invasive intracranial pressure estimation using ultrasonographic measurement of area of optic nerve subarachnoid space.
PubMed 文献 · Br J Ophthalmol · 2022-08-24

研究纳入90例接受持续有创颅内压监测的神经系统疾病患者,经眼眶超声测量视神经蛛网膜下腔面积(ONSASA)、视神经鞘直径等指标,探索其与颅内压的关系。在训练组中,ONSASA与颅内压的相关系数(r=0.953)高于视神经鞘直径(r=0.672)和3 mm处视神经蛛网膜下腔宽度(r=0.691)。以20 mm Hg为高低颅内压分界,ONSASA预测颅内压的灵敏度和特异度分别为1.00和0.92。

要点

  • 视神经蛛网膜下腔面积与颅内压的相关系数r=0.953,高于视神经鞘直径的r=0.672。
  • 以20 mm Hg为界,ONSASA预测颅内压的灵敏度为1.00,特异度为0.92。
  • 预测颅内压升高的ONSASA截断值为19.96,曲线下面积=0.960(95%CI 0.865至1.00)。

核心结论

  • 利用超声测量视神经蛛网膜下腔面积可作为快速、无创量化评估颅内压的实用方法,并可通过纳入体重指数和平均动脉压的数学公式进行推算。

研究设计与样本

  • 研究纳入90例接受持续有创颅内压监测的神经系统疾病患者,记录视神经直径、视神经鞘直径、距视神经头3 mm处视神经蛛网膜下腔两侧宽度及3至7 mm之间勾勒的整个视神经蛛网膜下腔面积,比较五种模型后确定最佳模型。

主要发现

  • 在训练组中,颅内压与视神经蛛网膜下腔面积的相关系数(Pearson相关系数r=0.953)高于颅内压与视神经鞘直径的相关系数(r=0.672;p<0.0001)及颅内压与距眼球后3 mm处视神经蛛网膜下腔宽度的相关系数(r=0.691;p<0.0001)。
  • 在训练组中,预测颅内压的加权函数为:无创颅内压=2.050×视神经蛛网膜下腔面积-0.051×体重指数+0.036×平均动脉压-5.837。
  • 以20 mm Hg作为颅内压高低的分界点,视神经蛛网膜下腔面积预测颅内压的灵敏度和特异度分别为1.00和0.92。
  • 受试者工作特征曲线分析显示,预测颅内压升高的计算截断值为19.96(曲线下面积=0.960,95%CI 0.865至1.00)。

关键数值与推荐

  • 以20 mm Hg为颅内压高低分界点时,视神经蛛网膜下腔面积预测颅内压的灵敏度为1.00,特异度为0.92。
  • 预测颅内压升高的视神经蛛网膜下腔面积截断值为19.96,曲线下面积=0.960(95%CI 0.865至1.00)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To verify whether the area of the ONSAS (ONSASA) obtained by transorbital ultrasonography can be used to accurately evaluate the intracranial pressure (ICP). METHODS: The recorded indexes included the optic nerve diameter, the optic nerve sheath diameter (ONSD), the width of both sides of the ONSAS (ONSASW) at 3 mm from the optic nerve head and the entire ONSASA outlined between 3 and 7 mm. After exploring and comparing five models to describe the relationship between body mass index (BMI), mean arterial blood pressure (MABP), ONSASA and ICP, the best model was determined. RESULTS: In all, 90 patients with neurological diseases undergoing continuous invasive ICP monitoring were included in the study. In the training group, the correlation coefficient for the association between the ICP and ONSASA (Pearson's correlation r=0.953) was higher than that for the association of the ICP with the ONSD (r=0.672; p<0.0001) and ONSASW at 3 mm behind the globe (r=0.691; p<0.0001). In the training group, the weighting function for prediction of the ICP was as follows: non-invasive ICP=2.050×ONSASA-0.051×BMI +0.036*MABP-5.837. With 20 mm Hg as the cut-off point for a high or low ICP, the sensitivity and specificity of ONSASA predicting ICP was 1.00 and 0.92. Receiver operator curve analysis revealed that the calculated cut-off value for predicting elevated ICP was 19.96 (area under curve= 0.960, 95% CI 0.865 to 1.00). CONCLUSION: Measurement of the ONSASA using ultrasonography can serve as a practical method for rapid and non-invasive quantification for evaluating ICP through an accurate mathematical formula with the BMI and MABP considered as contributing parameters. TRIAL REGISTRATION NUMBER: The study was registered in the Chinese Clinical Trial Registry (Study no ChiCTR2100045274).

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Cao K, Pang R, et al. Non-invasive intracranial pressure estimation using ultrasonographic measurement of area of optic nerve subarachnoid space. Br J Ophthalmol. 2022. PMID: 36002239. doi:10.1136/bjo-2022-321065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。