小梁切除术或青光眼引流装置术后视网膜裂孔性脱离的患病率、特征与结局
该研究回顾性分析了2016年1月1日至2021年1月1日在Wills眼科医院诊断为视网膜裂孔性脱离(RRD)且有抗青光眼滤过手术史的患者,共46眼。5年RRD患病率为0.71%(26/3664,95% Poisson置信区间0.48%-1.04%)。多数患者表现为黄斑受累的脱离并常伴增殖性玻璃体视网膜病变,解剖和视力结局较差。
要点
- 抗青光眼滤过手术后5年RRD患病率为0.71%(26/3664)。
- 76.1%的患眼表现为黄斑脱离,41.3%术前存在增殖性玻璃体视网膜病变。
- 一次手术成功率为65.2%(30/46),最终视力较术前无显著差异(P=0.2853)。
核心结论
- 小梁切除术或青光眼引流装置术后5年RRD患病率为0.71%。
- 多数患者表现为黄斑受累的脱离,常伴增殖性玻璃体视网膜病变。
- 解剖和视力结局较差。
研究设计与样本
- 回顾性研究,纳入2016年1月1日至2021年1月1月在Wills眼科医院诊断为RRD且有小梁切除术或青光眼引流装置手术史的患者,共46眼。
主要发现
- 平均年龄60.7±19.6岁,15例(32.6%)为女性。
- 34眼(73.9%)诊断为原发性开角型青光眼。
- 最近一次抗青光眼手术至RRD诊断的平均时间为1,133±1,644天。
- 19眼(41.3%)术前存在增殖性玻璃体视网膜病变,其中9眼(19.6%)为C级;35眼(76.1%)就诊时为黄斑脱离。
- 就诊时4眼(8.7%)合并眼内炎,5眼(10.9%)合并脉络膜脱离,2眼(4.7%)合并玻璃体积血。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To describe the prevalence, management, and outcomes of rhegmatogenous retinal detachment (RRD) after incisional glaucoma filtering surgery. METHODS: All patients with a history of trabeculectomy or glaucoma drainage device surgery who were subsequently diagnosed with an RRD from January 1, 2016, to January 1, 2021, at the Wills Eye Hospital were identified. RESULTS: Forty-six eyes met the inclusion criteria. The mean age was 60.7 ± 19.6 years, and 15 patients (32.6%) were female. Of all eyes, 34 (73.9%) were diagnosed with primary open-angle glaucoma. The mean time from most recent incisional glaucoma surgery to RRD diagnosis was 1,133 ± 1,644 days. There were 19 eyes (41.3%) with preoperative proliferative vitreoretinopathy (9 eyes [19.6%] with Grade C proliferative vitreoretinopathy) and 35 eyes (76.1%) had macula-off RRD at the time of presentation. At RRD presentation, 4 eyes (8.7%) had concomitant endophthalmitis, 5 (10.9%) had concurrent choroidal detachment, and 2 (4.7%) had concurrent vitreous hemorrhage. Primary vitrectomy was performed in most (91.3%) cases. Silicone oil tamponade was often required (71.1%). The single surgery success rate was 65.2% (30 of 46). The mean preoperative logarithm of the minimum angle of resolution visual acuity was 1.72 ± 0.78 (Snellen acuity 20/1,050), and the mean final postoperative logarithm of the minimum angle of resolution was 1.59 ± 0.89 (20/778, P = 0.2853). Of glaucoma surgeries performed, the 5-year prevalence of RRD was 0.71% (26 of 3,664, 95% Poisson confidence interval 0.48%-1.04%). CONCLUSION: The 5-year prevalence of RRDs after trabeculectomy or glaucoma drainage device was 0.71%. Most patients presented with macula-involving detachments, often with proliferative vitreoretinopathy. Anatomical and visual outcomes were poor.
引用
- Starr MR, Huang D, Wong JC, et al. PREVALENCE, CHARACTERISTICS, AND OUTCOMES OF RHEGMATOGENOUS RETINAL DETACHMENT IN EYES WITH TRABECULECTOMY OR GLAUCOMA DRAINAGE DEVICES. Retina. 2022. PMID: 35963003. doi:10.1097/IAE.0000000000003587
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。