文献速递眼底病与葡萄膜炎白内障与屈光手术

硅油填充眼行硅油取出联合白内障超声乳化术后使用8种公式计算人工晶状体的评估

Intraocular Lens Calculation Using 8 Formulas in Silicone Oil-Filled Eyes Undergoing Silicone Oil Removal and Phacoemulsification After Retinal Detachment.
PubMed 文献 · Am J Ophthalmol · 2022-07-16

该回顾性连续病例系列在德国法兰克福歌德大学眼科纳入90只硅油填充眼,比较8种人工晶状体计算公式在硅油取出联合白内障超声乳化及人工晶状体植入术前的预测误差,Barrett Universal II公式中位绝对误差最低(0.43 D ± 0.75),±0.5 D内比例最高(57.8%,52眼),但作者指出硅油填充眼预测性仍不及未手术眼。

要点

  • Barrett Universal II公式中位绝对误差最低,为0.43 D ± 0.75。
  • Barrett Universal II公式在±0.5 D内比例最高,为57.8%(52眼)。
  • 作者认为硅油填充眼预测性仍不及未手术眼。

核心结论

  • 使用现代公式计算硅油填充眼的人工晶状体可改善预测性,但仍不及未手术眼。
  • 作者指出该问题源于硅油填充导致屈光指数改变,进而使眼轴测量和有效晶状体位置预测精度降低。

研究设计与样本

  • 回顾性连续病例系列,在德国法兰克福歌德大学眼科开展。
  • 纳入90只硅油填充眼,均接受硅油取出联合白内障超声乳化及人工晶状体植入。
  • 术前使用IOLMaster 700(Carl Zeiss Meditec)进行生物测量,比较8种公式的平均预测误差、平均绝对预测误差和中位绝对预测误差。

主要发现

  • 中位绝对误差最低为Barrett Universal II公式(0.43 D ± 0.75),其次为Kane(0.44 D ± 0.75)、Hill-radial basis function(0.47 D ± 0.74)、Holladay II(0.47 D ± 0.77)、Sanders Retzlaff Kraff/theoretical(0.51 D ± 0.74)、Holladay I(0.51 D ± 0.76),Haigis与Hoffer Q均为0.52 D ± 0.74。
  • 在±0.5 D范围内,Barrett Universal II公式比例最高(57.8%,52眼),其次为Kane(56.7%,51眼)和Hill-radial basis function(54.4%,49眼)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate formulas for intraocular lens (IOL) calculation in silicone oil (SO)-filled eyes. DESIGN: Retrospective, consecutive case series. METHODS: We conducted our study at the Department of Ophthalmology, Goethe University, Frankfurt, Germany, and included SO-filled eyes that received SO removal combined with phacoemulsification and IOL implantation. Preoperative assessments included biometry (IOLMaster 700; Carl Zeiss Meditec). To evaluate the measurements, we compared the mean prediction error, and mean and median absolute prediction error of 8 different formulas. RESULTS: A total of 90 eyes matched our inclusion criteria. The median absolute error was lowest in the Barrett Universal II formula (0.43 diopters [D] ± 0.75) followed by Kane (0.44 D ± 0.75), Hill-radial basis function (0.47 D ± 0.74), Holladay II (0.47 D ± 0.77), Sanders Retzlaff Kraff/theoretical (0.51 D ± 0.74), Holladay I (0.51 D ± 0.76), and Haigis and Hoffer Q (0.52 D ± 0.74 each). Regarding eyes within ±0.5 D Barrett Universal II (57.8%, 52 eyes) performed best, again followed by Kane (56.7%, 51 eyes) and Hill-radial basis function (54.4%, 49 eyes). CONCLUSION: Using modern formulas for IOL calculation in oil-filled eyes improves predictability but still not as good as in unoperated eyes. This issue is created by the change in refractive index due to the SO fill and therefore a lower precision of axial length measurement and effective lens position prediction.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lwowski C, Miraka K, Müller M, et al. Intraocular Lens Calculation Using 8 Formulas in Silicone Oil-Filled Eyes Undergoing Silicone Oil Removal and Phacoemulsification After Retinal Detachment. Am J Ophthalmol. 2022. PMID: 35853490. doi:10.1016/j.ajo.2022.07.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。