文献速递青光眼

眼睑肌肉动作和揉眼对植入眼压传感器的青光眼患者遥测眼压的影响

Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant.
PubMed 文献 · Br J Ophthalmol · 2022-06-14

本研究对11例曾植入遥测眼压传感器(Eyemate-IO)的原发性开角型青光眼(POAG)患者进行遥测眼压测量,记录其基线、指令眨眼、闭眼、挤眼和揉眼时的眼压峰值变化。结果显示揉眼和挤眼引起的眼压峰值升高尤其明显,作者认为需进一步研究其对青光眼进展的潜在影响。

要点

  • 揉眼时平均眼压峰值较基线升高59.1±9.6 mm Hg(p<0.001)。
  • 挤眼时平均眼压峰值较基线升高42.2±5.8 mm Hg(p<0.0001)。
  • 闭眼和自主眨眼分别升高3.8±0.6 mm Hg(n=9,p<0.01)和11.6±2.4 mm Hg(p<0.001)。

核心结论

  • POAG患者的眼睑动作会引起眼压短暂升高,其中挤眼和揉眼时升高尤其明显。
  • 作者认为需进一步研究这些眼压升高对青光眼进展的潜在影响。

研究设计与样本

  • 研究纳入11例曾植入遥测眼压传感器(Eyemate-IO)的原发性开角型青光眼(POAG)患者。
  • 患者先直视前方1分钟作为基线测量,随后进行6次指令眨眼(间隔10秒)。
  • 另进行5次闭眼(n=9)、挤眼和揉眼(n=7),间隔15秒。
  • 通过围绕研究眼放置的外部天线记录眼压,分析眼压峰值较基线的平均升高值,并用单样本t检验与零(无变化)比较。

主要发现

  • 揉眼时平均眼压峰值较基线升高59.1±9.6 mm Hg(p<0.001)。
  • 挤眼时平均眼压峰值较基线升高42.2±5.8 mm Hg(p<0.0001)。
  • 闭眼时平均眼压峰值较基线升高3.8±0.6 mm Hg(n=9,p<0.01)。
  • 自主眨眼时平均眼压峰值较基线升高11.6±2.4 mm Hg(p<0.001)。
  • 不自主眨眼期间除眼脉搏出现短暂不规则外,未观察到眼压变化。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. van den Bosch JJON, Pennisi V, Mansouri K, et al. Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant. Br J Ophthalmol. 2022. PMID: 35701079. doi:10.1136/bjophthalmol-2021-320508

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。