文献速递青光眼眼底病与葡萄膜炎

高轴性近视与非高轴性近视青光眼眼的黄斑结构与血管差异

Macula structural and vascular differences in glaucoma eyes with and without high axial myopia.
PubMed 文献 · Br J Ophthalmol · 2022-06-20

该横断面研究纳入270例青光眼患者(438眼),分为非近视组163眼、轻度近视组218眼和高近视组(轴长>26 mm)57眼,评估轴长和视野平均偏差与黄斑各视网膜层厚度及浅层血管密度的关联。结果显示,较薄的全局视网膜神经节细胞内丛状层和神经节细胞复合体与更差的视野平均偏差显著相关(R²分别为34.5%和32.9%,均p<0.001),但与轴长无显著关联(均p>0.1)。

要点

  • 较薄的全局视网膜神经节细胞内丛状层和神经节细胞复合体与更差的视野平均偏差显著相关,但与轴长无显著关联。
  • 较厚的黄斑视网膜神经纤维层与轴长增加呈弱关联(R²=2.4%,p=0.005),与视野平均偏差呈正相关(全局R²=19.2%,p<0.001)。
  • 较低的浅层血管密度与轴长增加呈弱关联(R²=1.8%,p=0.028),与更严重的青光眼视野平均偏差关联更强(R²=29.6%,p<0.001)。

核心结论

  • 较薄的全局视网膜神经节细胞内丛状层和神经节细胞复合体与青光眼严重程度增加相关,但与轴长无显著关联,可能有助于高度近视眼的青光眼监测。

研究设计与样本

  • 诊断创新青光眼横断面研究,纳入270例青光眼患者共438眼,分为非近视组163眼、轻度近视组218眼和高近视组(轴长>26 mm)57眼,完成黄斑光学相干断层扫描和光学相干断层扫描血管成像。

主要发现

  • 较薄的全局视网膜神经节细胞内丛状层和神经节细胞复合体与更差的视野平均偏差显著相关(R²=34.5%和R²=32.9%,均p<0.001),但与轴长无显著关联(均p>0.1)。
  • 较厚的黄斑视网膜神经纤维层与轴长增加呈弱关联(R²=2.4%,p=0.005),与视野平均偏差呈正相关(全局R²=19.2%,p<0.001)。
  • 较低的浅层血管密度与轴长增加呈弱关联(R²=1.8%,p=0.028),与更严重的青光眼视野平均偏差关联更强(R²=29.6%,p<0.001)。
  • 较薄的黄斑脉络膜厚度与轴长增加相关(R²=15.5%,p<0.001),与视野平均偏差无关联(p=0.194)。
  • 在所有扇区中,高度近视眼的黄斑视网膜神经纤维层最厚,而黄斑脉络膜厚度最薄。

临床怎么用

  • 作者认为,由于较薄的视网膜神经节细胞内丛状层和神经节细胞复合体与青光眼严重程度增加相关而与轴长无显著关联,它们可能有助于高度近视眼的青光眼监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To identify clinically relevant parameters for identifying glaucoma in highly myopic eyes, an investigation was conducted of the relationship between the thickness of various retinal layers and the superficial vessel density (sVD) of the macula with axial length (AL) and visual field mean deviation (VFMD). METHODS: 270 glaucoma patients (438 eyes) participating in the Diagnostic Innovations in Glaucoma cross-sectional study representing three axial myopia groups (non-myopia: n=163 eyes; mild myopia: n=218 eyes; high myopia (AL>26 mm): n=57 eyes) who completed macular optical coherence tomography (OCT) and OCT-angiography imaging were included. Associations of AL and VFMD with the thickness of the ganglion cell inner plexiform layer (GCIPL), macular retinal nerve fibre layer (mRNFL), ganglion cell complex (GCC), macular choroidal thickness (mCT) and sVD were evaluated. RESULTS: Thinner Global GCIPL and GCC were significantly associated with worse VFMD (R2=34.5% and R2=32.9%; respectively p<0.001), but not with AL (all p>0.1). Thicker mRNFL showed a weak association with increasing AL (R2=2.4%; p=0.005) and a positive association with VFMD (global R2=19.2%; p<0.001). Lower sVD was weakly associated with increasing AL (R2=1.8%; p=0.028) and more strongly associated with more severe glaucoma VFMD (R2=29.6%; p<0.001). Thinner mCT was associated with increasing AL (R2=15.5% p<0.001) and not associated with VFMD (p=0.194). mRNFL was thickest while mCT was thinnest in all sectors of high myopic eyes. CONCLUSIONS: As thinner GCIPL and GCC were associated with increasing severity of glaucoma but were not significantly associated with AL, they may be useful for monitoring glaucoma in highly myopic eyes.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Rezapour J, Bowd C, Dohleman J, et al. Macula structural and vascular differences in glaucoma eyes with and without high axial myopia. Br J Ophthalmol. 2022. PMID: 35725293. doi:10.1136/bjophthalmol-2021-320430

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。