中国正常眼压性青光眼患者的角膜硬度与模量研究
前瞻性横断面比较研究纳入中山眼科中心334眼(正常眼压性青光眼108例、高眼压性青光眼113例、对照113例),用角膜压入装置和Corvis ST评估角膜生物力学。正常眼压性青光眼角膜硬度(71.0±10.9 N/m)低于高眼压性青光眼(77.3±15.6 N/m;P=.001)及匹配对照(75.6±11.0 N/m;P=.023),校正混杂后仍较低(β=-4.88,95%CI -9.002,-0.758;P=.020);角膜硬度与CCT正相关仅见于正常眼压性青光眼组(P=.028)。
要点
- 正常眼压性青光眼角膜硬度低于高眼压性青光眼及对照,校正混杂后仍较低(β=-4.88,P=.020)。
- 角膜硬度与中央角膜厚度正相关仅见于正常眼压性青光眼组(P=.028),高眼压性青光眼组无显著相关(P=.509)。
- 角膜生物力学与视野、视网膜神经纤维层厚度之间无显著相关(P>.05)。
核心结论
- 正常眼压性青光眼患者的角膜较高眼压性青光眼患者和对照更软,经角膜压入装置评估,且与较薄的中央角膜厚度相关。
- 这些发现可能提示正常眼压性青光眼与高眼压性青光眼具有不同的眼球生物力学特性。
研究设计与样本
- 前瞻性、横断面、比较性研究,纳入中山大学中山眼科中心334眼,包括正常眼压性青光眼108例、高眼压性青光眼113例和对照113例。
- 使用角膜压入装置和角膜可视化Scheimpflug技术评估角膜生物力学,标准自动视野计和频域光学相干断层扫描获取视野和视网膜神经纤维层厚度。
- 采用单因素方差分析及Bonferroni事后检验,以及校正后的多变量线性回归分析。
主要发现
- 正常眼压性青光眼角膜硬度(71.0±10.9 N/m)显著低于高眼压性青光眼(77.3±15.6 N/m;P=.001)和匹配对照(75.6±11.0 N/m;P=.023)。
- 校正混杂因素后,正常眼压性青光眼组角膜硬度仍低于对照组(β=-4.88,95%CI -9.002,-0.758;P=.020)。
- 角膜硬度与中央角膜厚度在正常眼压性青光眼组呈正相关(P=.028),在高眼压性青光眼组无显著相关(P=.509)。
- 角膜生物力学与视野或视网膜神经纤维层厚度之间无显著相关(P>.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess and compare the corneal biomechanics of normal-tension glaucoma (NTG), high-tension glaucoma (HTG), and normal controls based on stiffness and modulus. The correlations among central corneal thickness (CCT), visual field, retinal nerve fiber layer (RNFL) thickness, and corneal biomechanics in glaucoma eyes were also evaluated. DESIGN: A prospective, cross-sectional, comparative study. METHODS: This study included 334 eyes of 108 NTG patients, 113 HTG patients, and 113 control subjects at Zhongshan Ophthalmic Center, Sun Yat-Sen University. Corneal biomechanics were evaluated using a corneal indentation device (CID) and corneal visualization Scheimpflug technology (Corvis ST). Visual field and RNFL thickness were obtained using standard automated perimetry and spectral-domain optical coherence tomography. One-way analyses of variance with Bonferroni post hoc tests and a multivariable linear regression analysis with adjustment were conducted. Correlations among corneal biomechanical parameters, CCT, visual field, and RNFL thickness were analyzed. RESULTS: The corneal stiffness of the NTG patients (71.0 ± 10.9 N/m) was significantly lower than that of the HTG patients (77.3 ± 15.6 N/m; P = .001) and the CCT- and IOP-matched normal controls (75.6 ± 11.0 N/m; P = .023). The patients in the NTG group had lower corneal stiffness than those in the control group (β = -4.88, 95% CI -9.002, -0.758; P = .020) after adjusting for confounders. Stiffness was positively correlated with CCT in the NTG group (P = .028) but not in the HTG group (P = .509). There was no significant correlation (P > .05) between corneal biomechanics, visual field, or RNFL thickness. CONCLUSIONS: The corneas of NTG patients were softer than those of HTG patients and controls, as assessed by CID, which were associated with thinner CCT. These might suggest different ocular biomechanical properties in NTG and HTG.
引用
- Xu Y, Ye Y, Chen Z, et al. Corneal Stiffness and Modulus of Normal-Tension Glaucoma in Chinese. Am J Ophthalmol. 2022. PMID: 35764102. doi:10.1016/j.ajo.2022.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。