文献速递眼底病与葡萄膜炎

暗视轮廓变形检测揭示伴或不伴网状假性玻璃膜疣的年龄相关性黄斑变性早期视杆细胞功能障碍

Scotopic Contour Deformation Detection Reveals Early Rod Dysfunction in Age-Related Macular Degeneration With and Without Reticular Pseudodrusen.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2022-01-01

研究纳入41名参与者(9例伴网状假性玻璃膜疣的中间型年龄相关性黄斑变性、16例单纯中间型年龄相关性黄斑变性、16名对照),评估暗视轮廓变形检测及其结构决定因素。结果显示中间型年龄相关性黄斑变性组暗视轮廓变形阈值显著差于对照,且在暗视阈值正常或暗适应正常的患眼也可出现阈值升高,提示该任务可提供视杆细胞功能障碍的独特信息。

要点

  • 中间型年龄相关性黄斑变性组暗视轮廓变形阈值显著差于对照(下方8度视网膜P=0.004,4度位点均P<0.02)。
  • 在暗视阈值正常的中间型年龄相关性黄斑变性伴网状假性玻璃膜疣患眼及暗适应正常的中间型年龄相关性黄斑变性患眼中,可见暗视轮廓变形阈值升高。
  • 暗视轮廓变形阈值升高与年龄增长及对侧眼晚期年龄相关性黄斑变性相关。

核心结论

  • 新型暗视轮廓变形任务可提供中间型年龄相关性黄斑变性伴网状假性玻璃膜疣患者视杆细胞功能障碍的独特信息,而结构和其它功能评估未观察到该信息。
  • 暗视轮廓变形检测所观察到的视杆细胞功能障碍与年龄相关性黄斑变性进展风险相关因素有关。

研究设计与样本

  • 研究纳入41名参与者(年龄58-89岁),包括9例中间型年龄相关性黄斑变性伴网状假性玻璃膜疣、16例单纯中间型年龄相关性黄斑变性及16名对照,接受功能测试。
  • 暗视轮廓变形检测采用径向频率弧呈现于4个位点:±4度及8度垂直偏心率。
  • 在同一位点测量暗视阈值和暗适应,并对谱域光学相干断层扫描(SD-OCT)容积扫描的视网膜层进行分割。
  • 通过评估SD-OCT数据解释暗视轮廓变形阈值变异的比例,建立功能测试的同时效度。

主要发现

  • 中间型年龄相关性黄斑变性组暗视轮廓变形阈值显著差于对照(下方8度视网膜P=0.004,4度两个位点均P<0.02)。
  • 在暗视阈值正常的中间型年龄相关性黄斑变性伴网状假性玻璃膜疣患眼及暗适应正常的中间型年龄相关性黄斑变性患眼中,观察到暗视轮廓变形阈值升高;相反情况罕见遇到。
  • 暗视轮廓变形阈值升高与年龄增长及对侧眼晚期年龄相关性黄斑变性相关。
  • 最佳机器学习模型预测了8度位点暗视轮廓变形阈值变异的16%(交叉验证R2)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate scotopic contour deformation detection (sCDD), and its structural determinants, in participants with intermediate age-related macular degeneration (iAMD) with or without reticular pseudodrusen (RPD). METHODS: Forty-one participants (aged 58-89 years), including 9 with iAMD and RPD, 16 with iAMD only, and 16 controls, underwent functional testing. The sCDD was evaluated with radial frequency arcs presented at 4 loci: ±4 degrees and 8 degrees vertical eccentricity. Scotopic thresholds and dark adaptation (DA) were measured at the same loci. Retinal layers of spectral domain optical coherence tomography (SD-OCT) volume scans were segmented. To establish the concurrent validity of the functional test, we evaluated the fraction of variability in sCDD thresholds explained by SD-OCT data. RESULTS: The iAMD group had significantly worse sCDD thresholds compared with controls (8 degrees inferior retina: P = 0.004 and the 4 degrees loci: P < 0.02 for both). Elevated sCDD thresholds were observed in iAMD and RPD eyes at loci with normal scotopic thresholds; the opposite was rarely encountered. Elevated sCDD thresholds were also observed in iAMD eyes with normal DA. Elevated sCDD thresholds were associated with increased age and presence of late AMD in the fellow eye. The optimal machine learning model predicted 16% of variability (cross-validated R2) in sCDD thresholds at 8 degrees. DISCUSSION: A novel scotopic contour deformation task can provide unique information about rod dysfunction in participants with iAMD and RPD not observed with structural and other functional assessments. Rod dysfunction observed with scotopic contour deformation testing was associated with factors linked to risk of AMD progression.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Jeffrey BG, Flynn OJ, Huryn LA, et al. Scotopic Contour Deformation Detection Reveals Early Rod Dysfunction in Age-Related Macular Degeneration With and Without Reticular Pseudodrusen. Invest Ophthalmol Vis Sci. 2022. PMID: 35749129. doi:10.1167/iovs.63.6.23

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。