过滤空气与六氟化硫气体填塞在无并发症下方裂孔视网膜脱离玻璃体切除术中的比较
本研究比较了过滤空气与20%六氟化硫(SF6)气体作为内填塞在初次25G经平坦部玻璃体切除术治疗无并发症下方裂孔孔源性视网膜脱离中的手术结局。共纳入116眼,空气组52眼、气体组64眼。结论认为两种填塞方式在单次手术解剖成功率和最终视力恢复上无显著差异。
要点
- 无并发症下方裂孔孔源性视网膜脱离行25G玻璃体切除术,空气与20% SF6填塞的单次手术解剖成功率无显著差异(96.2% vs 93.8%,P=0.69)。
- 结论认为空气与SF6气体填塞在上述人群中手术结局无显著差异。
核心结论
- 在初次25G经平坦部玻璃体切除术治疗无并发症下方裂孔孔源性视网膜脱离中,空气与SF6气体填塞的单次手术解剖成功率和最终视力恢复无显著差异。
研究设计与样本
- 研究纳入无并发症孔源性视网膜脱离伴下方裂孔(4点至8点方位)行初次经平坦部玻璃体切除术的患者,所有眼行玻璃体切除及完全视网膜下液引流后随机或分配接受过滤空气或20% SF6填塞。
- 共评估116例患者的116眼,其中男性81例、女性35例,平均年龄55.2岁;空气组52眼,气体组64眼。
主要发现
- 单次手术解剖成功:空气组50眼(96.2%)vs 气体组60眼(93.8%),P=0.69。
- 最终解剖成功:所有眼均达到。
- 最终平均Snellen视力:空气组20/23 vs 气体组20/21,P=0.13。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare surgical outcomes of filtered air and sulfur hexafluoride (SF6) as an internal tamponade in patients undergoing primary 25-gauge pars plana vitrectomy for uncomplicated rhegmatogenous retinal detachment with inferior breaks. METHODS: Patients with uncomplicated rhegmatogenous retinal detachment associated with inferior breaks (between 4 and 8 o'clock positions) who were undergoing primary pars plana vitrectomy were enrolled. All eyes underwent pars plana vitrectomy and complete drainage of subretinal fluid, followed by filtered air or 20% SF6 tamponade. The main outcome measures included single-surgery anatomical success rates and final visual recovery. RESULTS: Overall, 116 eyes of 116 patients (81 men and 35 women with a mean age of 55.2 years) were assessed. Air was used in 52 eyes (air group) and gas in 64 eyes (gas group). Single-surgery anatomical success was achieved in 50 (96.2%) and 60 (93.8%) eyes in the air and gas groups, respectively (P = 0.69), and final anatomical success was achieved in all eyes. The mean final Snellen visual acuity was similar in the air (20/23) and gas groups (20/21; P = 0.13). CONCLUSION: No significant differences were observed in single-surgery anatomical success rates and final visual recovery when comparing air with SF6 gas tamponade in pars plana vitrectomy for primary uncomplicated rhegmatogenous retinal detachment with inferior breaks.
引用
- Uemura A, Mihara N, Yamakiri K, et al. AIR VERSUS SULFUR HEXAFLUORIDE GAS TAMPONADE IN VITRECTOMY FOR UNCOMPLICATED RETINAL DETACHMENT WITH INFERIOR BREAKS. Retina. 2022. PMID: 35723919. doi:10.1097/IAE.0000000000003470
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。