文献速递眼底病与葡萄膜炎

激光光凝预防急性视网膜坏死中视网膜脱离的有效性:系统综述与Meta分析

EFFICIENCY OF LASER PHOTOCOAGULATION ON THE PREVENTION OF RETINAL DETACHMENT IN ACUTE RETINAL NECROSIS: A Systematic Review and Meta-Analysis.
PubMed 文献 · Retina · 2022-01-01

该系统综述与Meta分析检索PubMed、Embase和Cochrane数据库,纳入14项研究共532只眼,评估预防性激光光凝对急性视网膜坏死继发视网膜脱离的预防效果。合并结果显示,激光治疗组发生视网膜脱离的比值比为0.61(95%CI 0.41~0.90,P<0.05,I²=27%)。作者结论认为,激光光凝是预防急性视网膜坏死患者视网膜脱离的有效治疗,尤其在联合抗病毒治疗和类固醇的亚组中。

要点

  • 纳入14项研究共532只眼,研究质量中等,合并OR为0.61(95%CI 0.41~0.90,P<0.05,I²=27%)。
  • 敏感性分析显示排除任一研究后OR相似,亚组分析显示三个亚组间存在中度异质性(I²=48.0%,P=0.15)。
  • 抗病毒治疗和类固醇联合预防性激光亚组的OR为0.43(95%CI 0.25~0.74,P<0.05,I²=0%)。

核心结论

  • 在急性视网膜坏死患者中,激光光凝是预防视网膜脱离的有效治疗,尤其在联合抗病毒治疗和类固醇的亚组中。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase和Cochrane数据库,纳入14项研究共532只眼,每项研究均有明确的激光治疗组和未行激光治疗的对照组或可手动分组的数据。
  • 纳入研究质量采用ROBINS-I(非随机干预研究偏倚风险)工具评估,质量为中等。
  • Meta分析计算合并比值比及其95%置信区间,敏感性分析检验稳健性,亚组分析确定异质性来源。

主要发现

  • 合并结果显示,激光治疗组发生视网膜脱离的比值比为0.61(95%CI 0.41~0.90,P<0.05,I²=27%)。
  • 敏感性分析显示排除任一研究后比值比相似。
  • 亚组分析显示三个亚组间存在中度异质性(I²=48.0%,P=0.15)。
  • 抗病毒治疗和类固醇联合预防性激光亚组的比值比为0.43(95%CI 0.25~0.74,P<0.05,I²=0%)。

关键数值与推荐

  • 合并比值比0.61(95%CI 0.41~0.90,P<0.05,I²=27%),对应激光治疗组与未行激光治疗对照组比较。
  • 抗病毒治疗和类固醇联合预防性激光亚组的比值比0.43(95%CI 0.25~0.74,P<0.05,I²=0%)。

临床怎么用

  • 原文结论认为,对急性视网膜坏死患者,激光光凝是预防视网膜脱离的有效治疗,尤其在联合抗病毒治疗和类固醇的亚组中。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Retinal detachment is a severe complication of acute retinal necrosis, threatening vision. The published articles on the effectiveness of laser in preventing retinal detachment in acute retinal necrosis are controversial. Therefore, we aim to evaluate whether prophylactic laser is effective for retinal detachment after acute retinal necrosis. METHODS: PubMed, Embase, and Cochrane databases were searched, and the retrieved records were screened. Each included study has well-defined laser-treated group and control group without laser treatment or with enough data for manual grouping. The quality of the included studies was assessed using ROBINS-I ("Risk Of Bias In Nonrandomized Studies-of Interventions"). Meta-analysis was conducted to calculate the pooled odds ratios and their 95% confidence interval. Sensitivity analysis was used to test the solidarity, and subgroup analysis was performed to determine the source of heterogeneity. RESULTS: Fourteen studies with a total of 532 eyes were eventually included. The quality of the included studies was moderate. The combined results showed that the pooled odds ratio was 0.61 (95% confidence interval [0.41∼0.90], P < 0.05, I 2 = 27%). Sensitivity analysis showed that the odds ratios were similar when excluding any study. Subgroup analysis showed moderate heterogeneity among three subgroups (I 2 = 48.0%, P = 0.15 for heterogeneity), and the odds ratio in antiviral therapy and steroid combined with prophylactic laser was 0.43 (95% confidence interval [0.25∼0.74], P < 0.05, I 2 = 0%). CONCLUSION: In patients with acute retinal necrosis, laser photocoagulation is an effective treatment to prevent retinal detachment, especially in the subgroup combined with antiviral therapy and steroid.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Chen M, Zhang M, Chen H, et al. EFFICIENCY OF LASER PHOTOCOAGULATION ON THE PREVENTION OF RETINAL DETACHMENT IN ACUTE RETINAL NECROSIS: A Systematic Review and Meta-Analysis. Retina. 2022. PMID: 35576609. doi:10.1097/IAE.0000000000003527

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。