文献速递眼底病与葡萄膜炎

光学相干断层扫描血管成像显示缓解期Vogt-Koyanagi-Harada综合征脉络膜厚度反常降低而血流增加

OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY REVEALS PARADOXICALLY DECREASING CHOROIDAL THICKNESS AND INCREASING BLOOD FLOW IN REMITTING VOGT-KOYANAGI-HARADA SYNDROME.
PubMed 文献 · Retina · 2022-01-01

前瞻性研究纳入活动期早期Vogt-Koyanagi-Harada综合征继发葡萄膜炎患者,在基线及治疗后缓解期行光学相干断层扫描血管成像。缓解期脉络膜厚度较活动期降低,而脉络膜血流指标反常升高。作者认为较大样本研究有待评估调整血流指数在评估和预测疾病活动度中的效力。

要点

  • 活动期与缓解期平均脉络膜厚度分别为581.65±108.29µm与318.34±72.85µm(P<0.01)。
  • 3×3mm板块平均调整血流指数活动期0.495±0.027 vs 缓解期0.519±0.0336(P=0.011)。
  • 6×6mm板块平均调整血流指数活动期0.487±0.037 vs 缓解期0.517±0.052(P=0.025)。

核心结论

  • 缓解期Vogt-Koyanagi-Harada综合征患者光学相干断层扫描血管成像显示脉络膜厚度降低而脉络膜血流反常增加。
  • 作者认为这可能反映活动期炎症浸润或肉芽肿增加脉络膜厚度并导致脉络膜毛细血管循环缓慢,缓解期该过程逆转。
  • 作者指出需要较大样本研究评估调整血流指数在评估和预测疾病活动度中的效力。

研究设计与样本

  • 前瞻性研究,纳入活动期早期Vogt-Koyanagi-Harada综合征继发葡萄膜炎患者。
  • 初筛招募25例患者39只眼,排除屈光间质混浊、黄斑下纤维化和脉络膜新生血管后,纳入14例患者23只眼。
  • 在基线及治疗后缓解期各行一次光学相干断层扫描血管成像检查,平均随访8.7±2.5个月。
  • 采用3×3mm和6×6mm脉络膜毛细血管板块评估旁中心凹调整血流指数作为脉络膜血流标志物。
  • 测量3个点(中心凹下及旁中心凹300µm处2点)的平均脉络膜厚度。

主要发现

  • 活动期与缓解期平均脉络膜厚度分别为581.65±108.29µm与318.34±72.85µm(P<0.01)。
  • 3×3mm板块平均调整血流指数活动期为0.495±0.027,缓解期为0.519±0.0336(P=0.011)。
  • 6×6mm板块平均调整血流指数活动期为0.487±0.037,缓解期为0.517±0.052(P=0.025)。

局限性

  • 作者指出需要较大样本研究评估调整血流指数在评估和预测疾病活动度中的效力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess changes in choroidal thickness and blood flow in active Vogt-Koyanagi-Harada syndrome and after remission using optical coherence tomography angiography. METHODS: This was a prospective study of patients with active early uveitis secondary to Vogt-Koyanagi-Harada syndrome. They underwent optical coherence tomography angiography imaging twice: at baseline and after remission on treatment. 3- × 3- and 6- × 6-mm choriocapillaris slabs were used to evaluate parafoveal adjusted flow index as a marker for choroidal blood flow. Mean choroidal thickness of 3 points (subfoveally and 2 points 300 µ m parafoveally) was also measured. RESULTS: Thirty-nine eyes of 25 patients were initially recruited. After excluding eyes with media opacity, submacular fibrosis, and choroidal neovascularization, 23 eyes of 14 patients were included. The mean follow-up period was 8.7 ± 2.5 months. Mean choroidal thickness in activity and remission was 581.65 ± 108.29 µ m and 318.34 ± 72.85 µ m respectively ( P < 0.01). Mean adjusted flow index in the 3- × 3-mm slabs activity and remission were 0.495 ± 0.027 and 0.519 ± 0.0336 ( P = 0.011), and the 6- × 6-mm slabs were 0.487 ± 0.037 and 0.517 ± 0.052 respectively ( P = 0.025). CONCLUSION: We demonstrate decreasing choroidal thickness with paradoxically increasing choroidal flow on optical coherence tomography angiography in remitting Vogt-Koyanagi-Harada syndrome. This may reflect inflammatory infiltrations or granulomas increasing choroidal thickness during activity and causing sluggish circulation of the choriocapillaris, and a reversal of this process with remission. These findings shed more light on the relationship between Vogt Koyanagi Harada syndrome and its underlying choroidal disturbances. Larger studies are needed to evaluate the efficacy of adjusted flow index in evaluating and predicting disease activity.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Fayed AE, Gerges TK. OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY REVEALS PARADOXICALLY DECREASING CHOROIDAL THICKNESS AND INCREASING BLOOD FLOW IN REMITTING VOGT-KOYANAGI-HARADA SYNDROME. Retina. 2022. PMID: 35552322. doi:10.1097/IAE.0000000000003525

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。