文献速递青光眼

青光眼眼内温度测量:工作日与季节波动

Measurement of intraocular temperature in glaucoma: week-day and seasonal fluctuations.
PubMed 文献 · Br J Ophthalmol · 2022-04-20

这项前瞻性、开放标签、多中心观察性研究分析了22例原发性开角型青光眼(POAG)患者22只眼的眼内温度(IOT)长期波动,患者在白内障手术中植入眼内压(IOP)传感器并自我测量IOP,共获得132745次读数。结果显示IOT在周日显著高于其他工作日,并呈明显季节模式,7月最高、1月最低。

要点

  • POAG患者植入眼内传感器后,周日IOT为34.57°C(95%CI 34.37至34.78),显著高于其他工作日(p<0.001)。
  • 其他工作日平均IOT范围为34.48°C至34.51°C。
  • IOT呈明显季节模式,7月最高为34.8°C(95%CI 34.56至34.97),1月最低为34.4°C(95%CI 34.15至34.56;p<0.001)。

核心结论

  • 本研究证明使用眼内传感器连续长期测量IOT具有可行性,结果显示IOT存在显著的短期和长期波动。
  • 需要开展研究以了解IOT波动对IOP、眼灌注和青光眼进展的影响。

研究设计与样本

  • 前瞻性、开放标签、多中心观察性研究,纳入22例POAG患者22只眼进行分析。
  • 所有入组患者在白内障手术中植入IOP传感器,遥测系统利用内置温度传感器对测得的IOP进行温度校正。
  • 患者被指导按需自我测量IOP,但每天至少4次;每次测量时IOP和IOT均记录在读取设备中。

主要发现

  • 患者平均年龄67.8±6.8岁,36.4%为女性。
  • 共获得21102个测量日的132745次读数。
  • 平均IOT在周日为34.57°C(95%CI 34.37至34.78),显著高于一周中任何其他工作日(p<0.001)。
  • 其他工作日平均IOT范围为34.48°C至34.51°C。
  • 全年IOT呈明显季节模式,7月最高为34.8°C(95%CI 34.56至34.97),1月最低为34.4°C(95%CI 34.15至34.56;p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate long-term intraocular temperature (IOT) variations in eyes with primary open-angle glaucoma (POAG) using an intraocular telemetric sensor. METHODS: This prospective, open-label, multicentre observational study analysed the IOT variations in 22 eyes of 22 patients with POAG. All enrolled patients underwent implantation of an intraocular pressure (IOP) sensor during cataract surgery. The telemetric system uses a built-in temperature sensor to control measured IOP for temperature. Each time a patient measures their IOP, both the IOP and IOT are recorded in the reader device. Patients were instructed to self-measure their IOP as often as desired, but at least four times daily. Recorded readings were retrieved and analysed using mixed effect models and pairwise comparisons using Bonferroni correction to assess the statistical significance of average IOT variations between each individual weekday and calendar month. RESULTS: The mean age of patients was 67.8±6.8 years and 36.4% were women. A total of 132 745 readings over 21 102 measurement-days were obtained. On average, IOT was significantly higher on Sundays (34.57°C; 95% CI 34.37 to 34.78) than on any other day of the week (p<0.001). Mean IOT on other weekdays ranged from 34.48°C to 34.51°C. Over the year, IOT followed a clear seasonal pattern, reaching its maximum in July (34.8°C; 95% CI 34.56 to 34.97) and its minimum in January (34.4°C; 95% CI 34.15 to 34.56; p<0.001). CONCLUSIONS: This study demonstrates the feasibility of continual and long-term measurement of IOT using intraocular sensors. The results show significant short-term and long-term fluctuations of IOT. Research is warranted to understand the impact of IOT variations on IOP, ocular perfusion and glaucoma progression.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Mansouri K, Gillmann K, Rao HL, et al. Measurement of intraocular temperature in glaucoma: week-day and seasonal fluctuations. Br J Ophthalmol. 2022. PMID: 35443998. doi:10.1136/bjophthalmol-2021-320495

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。