标准手术显微镜与数字辅助玻璃体视网膜手术系统之间外科医生肌肉特性的比较

COMPARISON OF SURGEON MUSCULAR PROPERTIES BETWEEN STANDARD OPERATING MICROSCOPE AND DIGITALLY ASSISTED VITREORETINAL SURGERY SYSTEMS.
PubMed 文献 · Retina · 2022-01-01

该研究定量分析标准手术显微镜(SOM)与数字辅助玻璃体视网膜手术(DAVS)系统的手术工效学。外科医生对110例患者手术:52例联合超声乳化玻璃体切割(Phaco-PPV组,24例用SOM,28例用DAVS),58例超声乳化(Phaco组,30例用SOM,28例用DAVS)。结果SOM组术中胸锁乳突肌和上斜方肌两位置(UT1、UT2)肌张力和硬度高于术前术后(P<0.05),而DAVS组各时间点各测量部位无差异(P>0.05)。结论提示与SOM相比,DAVS可减少术中肌肉疲劳。

要点

  • SOM组术中胸锁乳突肌、UT1和UT2肌张力和硬度均高于术前和术后(P<0.05)。
  • DAVS组各测量部位各时间点肌肉特性均无差异(P>0.05)。
  • 结论提示与SOM相比,DAVS可减少术中肌肉疲劳。

核心结论

  • 本研究提供视网膜外科医生工效学的定量测量,提示与SOM相比,DAVS可减少术中肌肉疲劳。

研究设计与样本

  • 外科医生对110例患者进行手术:52例联合超声乳化玻璃体切割(Phaco-PPV组,24例用SOM,28例用DAVS),58例超声乳化(Phaco组,30例用SOM,28例用DAVS)。
  • 测量胸锁乳突肌和上斜方肌两个位置(UT1、UT2,沿上斜方肌纤维间隔2厘米)的肌张力和硬度,在术前、术中、术后时间点。

主要发现

  • SOM组Phaco-PPV组术中胸锁乳突肌、UT1和UT2肌张力和硬度高于术前和术后(P<0.001,分别;UT2硬度P<0.01)。
  • SOM组Phaco组术中胸锁乳突肌和UT1肌张力和硬度高于术前和术后(P<0.001,分别;UT1硬度P<0.01)。
  • DAVS组Phaco-PPV和Phaco组各测量部位各时间点肌肉特性均无差异(P>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To quantitatively analyze surgical ergonomics between standard operating microscope (SOM) and digitally assisted vitreoretinal surgery (DAVS) systems. METHODS: The surgeon conducted procedures on 110 patients; 52 patients underwent a combined phacoemulsification and pars plana vitrectomy (Phaco-PPV group, 24 using SOM and 28 using DAVS), and 58 patients underwent phacoemulsification (Phaco group, 30 using SOM and 28 using DAVS). The surgeon's muscle tone and stiffness in the sternocleidomastoid and the two positions of the upper trapezius (UT), which are 2-cm intervals along the UT muscle fibers, UT1 and UT2, were measured at preoperative, intraoperative, and postoperative time points. RESULTS: In the Phaco-PPV group using the SOM, intraoperative muscle tone and stiffness were higher than preoperative and postoperative values in the sternocleidomastoid ( P < 0.001, respectively), UT1 ( P < 0.001, respectively), and UT2 ( P < 0.001 and P < 0.01, respectively). In the Phaco group using the SOM, intraoperative muscle tone and stiffness were higher than pre- and postoperative values in the sternocleidomastoid ( P < 0.001, respectively) and UT1 ( P < 0.001 and P < 0.01, respectively). By contrast, when the surgeon used the DAVS, there were no differences in muscle properties at any measurement site or during any time point in the Phaco-PPV and Phaco groups ( P > 0.05). CONCLUSION: This study provides quantitative measurement of retina surgeon ergonomics, suggesting that compared with a SOM, the DAVS can reduce intraoperative muscle fatigue.