文献速递青光眼神经眼科

视网膜中央血管主干及分支的三维结构构型作为青光眼生物标志物

The three-dimensional structural configuration of the central retinal vessel trunk and branches as a glaucoma biomarker.
PubMed 文献 · Am J Ophthalmol · 2022-03-02

本研究为回顾性深度学习诊断研究,训练网络从视神经乳头OCT容积B扫描中自动分割视网膜中央血管主干及分支(CRVT&B),并分别用三维卷积神经网络和正交投影二维卷积神经网络诊断青光眼。分割Dice系数0.81±0.07,三维与二维诊断准确率分别为82.7%和83.3%,AUC分别为0.89和0.90,均高于单独使用视网膜神经纤维层(RNFL)厚度的AUC 0.74至0.80。作者认为CRVT&B的诊断能力优于RNFL厚度这一青光眼金标准参数。

要点

  • 深度学习可从OCT容积自动分割视网膜中央血管主干及分支,测试集Dice系数0.81±0.07。
  • 基于CRVT&B的三维和二维诊断网络准确率分别为82.7%和83.3%,AUC分别为0.89和0.90。
  • CRVT&B的AUC高于单独RNFL厚度(AUC 0.74至0.80),作者认为其诊断能力更优。

核心结论

  • 作者认为CRVT&B的诊断能力优于青光眼金标准参数RNFL厚度,并提示主要视网膜血管形成的「骨架」构型可能代表青光眼发生发展时通常可见的主要视神经乳头结构改变。

研究设计与样本

  • 回顾性深度学习诊断研究,训练网络从视神经乳头OCT容积B扫描中自动分割CRVT&B,并采用三维卷积神经网络和二维卷积神经网络两种方法诊断青光眼。
  • 分割精度以Dice系数评价,诊断精度以受试者工作特征曲线下面积(AUC)评价,并与同一队列中计算的RNFL厚度诊断性能比较。

主要发现

  • 分割网络能有效从OCT扫描中分割视网膜血管,测试集Dice系数为0.81±0.07。
  • 三维和二维诊断网络区分青光眼与非青光眼受试者的准确率分别为82.7%和83.3%。
  • CRVT&B对应的AUC分别为0.89和0.90,高于单独RNFL厚度所获得的AUC(范围0.74至0.80)。

关键数值与推荐

  • 分割精度指标为Dice系数0.81±0.07(测试集)。
  • 诊断性能指标为AUC:CRVT&B三维网络0.89、二维网络0.90;单独RNFL厚度AUC范围为0.74至0.80。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess whether the 3-dimensional (3D) structural configuration of the central retinal vessel trunk and its branches (CRVT&B) could be used as a diagnostic marker for glaucoma. DESIGN: Retrospective, deep-learning approach diagnosis study. METHODS: We trained a deep learning network to automatically segment the CRVT&B from the B-scans of the optical coherence tomography (OCT) volume of the optic nerve head. Subsequently, 2 different approaches were used for glaucoma diagnosis using the structural configuration of the CRVT&B as extracted from the OCT volumes. In the first approach, we aimed to provide a diagnosis using only 3D convolutional neural networks and the 3D structure of the CRVT&B. For the second approach, we projected the 3D structure of the CRVT&B orthographically onto sagittal, frontal, and transverse planes to obtain 3 two-dimensional (2D) images, and then a 2D convolutional neural network was used for diagnosis. The segmentation accuracy was evaluated using the Dice coefficient, whereas the diagnostic accuracy was assessed using the area under the receiver operating characteristic curves (AUCs). The diagnostic performance of the CRVT&B was also compared with that of retinal nerve fiber layer (RNFL) thickness (calculated in the same cohorts). RESULTS: Our segmentation network was able to efficiently segment retinal blood vessels from OCT scans. On a test set, we achieved a Dice coefficient of 0.81 ± 0.07. The 3D and 2D diagnostic networks were able to differentiate glaucoma from nonglaucoma subjects with accuracies of 82.7% and 83.3%, respectively. The corresponding AUCs for the CRVT&B were 0.89 and 0.90, higher than those obtained with RNFL thickness alone (AUCs ranging from 0.74 to 0.80). CONCLUSIONS: Our work demonstrated that the diagnostic power of the CRVT&B is superior to that of a gold-standard glaucoma parameter, that is, RNFL thickness. Our work also suggested that the major retinal blood vessels form a "skeleton"-the configuration of which may be representative of major optic nerve head structural changes as typically observed with the development and progression of glaucoma.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Panda SK, Cheong H, Tun TA, et al. The three-dimensional structural configuration of the central retinal vessel trunk and branches as a glaucoma biomarker. Am J Ophthalmol. 2022. PMID: 35247336. doi:10.1016/j.ajo.2022.02.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。