该回顾性观察趋势研究分析了2019年至2020年首尔大学医院青光眼科13,514只眼的眼底照片,确认454只眼存在视盘出血。温度每升高1°C,视盘出血风险比降至0.979(95%CI 0.969-0.989,P<.01);温度<10°C组相对≥20°C组的视盘出血发生比为1.53(95%CI 1.23-1.91,P<.01),冬季视盘出血患者眼压显著高于夏季。

要点

  • 温度每升高1°C,视盘出血风险比降至0.979(95%CI 0.969-0.989,P<.01)。
  • 温度<10°C组视盘出血发生比为1.53(95%CI 1.23-1.91,P<.01),相对≥20°C组。
  • 冬季视盘出血患者眼压显著高于夏季。

核心结论

  • 视盘出血受温度影响,呈现季节性变化。
  • 这种变异性被认为由眼压或血液学等温度相关因素导致。

研究设计与样本

  • 回顾性观察趋势研究,回顾2019年1月1日至2020年12月31日期间首尔大学医院青光眼科接受眼底照相的患者。
  • 共复习13,514只眼的眼底图像,其中454只眼确认存在视盘出血。
  • 通过照片确定视盘出血的月发生率,并获取和分析季节温度信息及患者眼压信息。

主要发现

  • 温度每升高1°C,视盘出血风险比降至0.979(95%CI 0.969-0.989,P<.01)。
  • 温度<10°C组相对≥20°C组的视盘出血发生比为1.53(95%CI 1.23-1.91,P<.01)。
  • 冬季视盘出血患者的眼压显著高于夏季所测眼压。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate seasonal variation in optic disc hemorrhage (DH) by review of fundus photographs representative of 2 calendar years (2019 and 2020). DESIGN: Retrospective, observational trend study. METHODS: Patients who visited the Glaucoma Clinic of Seoul National University Hospital and underwent fundus photography were included. All available stereo disc photographs and red-free retinal nerve fiber layer photographs taken between January 1, 2019 and December 31, 2020 were retrospectively reviewed. The monthly incidence rate of DH was determined by reference to the photographs. Seasonal temperature information and patients' intraocular pressure (IOP) information were obtained, organized, and analyzed. RESULTS: Fundus images of 13,514 eyes were reviewed, and 454 eyes were confirmed to have DH. Poisson regression analyses revealed that as the temperature (T) increased by 1 °C, the DH risk ratio was reduced to 0.979 (95% confidence interval [CI] 0.969-0.989, P < .01). The DH incidence ratio was 1.53 (95% CI 1.23-1.91, P < .01) for the T <10 °C group relative to the T ≥20 °C group. The IOP of the patients with DH in winter was significantly higher than that measured in summer. CONCLUSION: DH is affected by temperature, and as such, shows seasonal variability. This variability is believed to be caused by temperature-related factors such as IOP or hematological factors. © 2022 Elsevier Inc. All rights reserved.