文献速递眼底病与葡萄膜炎白内障与屈光手术

后房型虹膜爪式人工晶状体植入联合平坦部玻璃体切除术的结局

OUTCOMES OF RETROPUPILLARY IRIS CLAW INTRAOCULAR LENS IMPLANTATION COMBINED WITH PARS PLANA VITRECTOMY.
PubMed 文献 · Retina · 2022-02-17

回顾性分析2009年1月1日至2018年6月30日因复杂白内障手术囊膜丢失(A组)或人工晶状体脱位(B组)行虹膜爪式人工晶状体后房植入联合平坦部玻璃体切除术的患眼。A组49眼最佳矫正远视力中位数从术前0.523 logMAR改善至0.201 logMAR(P<0.01);B组126眼视力稳定(术前0.301 vs 术后0.222 logMAR,P>0.05)。结论认为该术式可提供 adequate 视力康复,在眼压变化方面似乎安全。

要点

  • A组49眼视力中位数从术前0.523 logMAR改善至0.201 logMAR,P<0.01。
  • B组126眼视力中位数术前0.301 logMAR vs 术后0.222 logMAR,P>0.05,无显著差异。
  • 12个月内A组眼压>21 mmHg者9眼(18.4%),B组15眼(11.9%)。

核心结论

  • 虹膜爪式人工晶状体后房植入联合平坦部玻璃体切除术可提供 adequate 视力康复,在眼压变化方面似乎安全。

研究设计与样本

  • 回顾性分析2009年1月1日至2018年6月30日行虹膜爪式人工晶状体植入联合平坦部玻璃体切除术的患眼。
  • A组为复杂白内障摘除伴囊膜丢失后无晶状体眼(n=49),B组为人工晶状体脱位眼(n=126)。
  • 分析12个月的最佳矫正远视力(logMAR)和眼压(mmHg)。

主要发现

  • A组49眼最佳矫正远视力中位数从术前0.523 logMAR(Snellen 20/65)改善至0.201 logMAR(Snellen 20/30),P<0.01。
  • B组126眼最佳矫正远视力中位数术前0.301 logMAR(Snellen 20/40)vs 术后0.222 logMAR(Snellen 20/30),P>0.05,无显著差异。
  • 12个月内A组眼压>21 mmHg者9眼(18.4%),无眼压<6 mmHg者。
  • 12个月内B组眼压>21 mmHg者15眼(11.9%),眼压<6 mmHg者5眼(4%)。
  • A组和B组在12个月随访时均无眼压>21 mmHg或<6 mmHg者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report 12-month visual outcomes, incidence of intraocular pressure (IOP) changes and postoperative complications after pars plana vitrectomy with retropupillary implantation of an iris claw intraocular lens (IOL) in aphakic eyes after complicated cataract surgery and eyes with a dislocation of the IOL. METHODS: This is a retrospective analysis of eyes undergoing implantation of an iris claw IOL combined with pars plana vitrectomy from 1st of January 2009 until 30th of June 2018 after complicated cataract extraction with capsular loss (Group A) or dislocation of an IOL (Group B). Corrected distance visual acuity was analyzed in logarithm of the minimum angle of resolution (logMAR) units, IOP was recorded in mmHg. RESULTS: Eyes in Group A (n = 49) improved from a preoperative median visual acuity of 0.523 logMAR (Snellen 20/65) to 0.201 logMAR (Snellen 20/30), P < 0.01. Eyes in Group B (n = 126) showed stable median visual acuity, preoperative 0.301 logMAR (Snellen 20/40) versus postoperative 0.222 logMAR (Snellen 20/30), P > 0.05. During 12 months in Group A, IOP >21 mmHg occurred in 9 (18.4%) eyes; no eye had an IOP <6 mmHg. In Group B, IOP >21 mmHg occurred in 15 (11.9%) eyes, IOP <6 mmHg in 5 (4%) cases. None of the eyes in Group A and B had IOP >21 mmHg or <6 mmHg at 12 months follow-up. CONCLUSION: The retropupillary implantation of an iris claw IOL with pars plana vitrectomy provides adequate visual rehabilitation and seems to be safe in IOP changes.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Zaleski M, Stahel M, Eberhard R, et al. OUTCOMES OF RETROPUPILLARY IRIS CLAW INTRAOCULAR LENS IMPLANTATION COMBINED WITH PARS PLANA VITRECTOMY. Retina. 2022. PMID: 35174810. doi:10.1097/IAE.0000000000003443

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。